DUCTILE IRON PIPES, FITTINGS AND ACCESSORIES - EXTERNAL CEMENT MORTAR COATING FOR PIPES - REQUIREMENTS AND TEST METHODS

Published date

03-07-2008

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Ordering information
5 Technical requirements
  5.1 Zinc coating
  5.2 Primer film thickness
  5.3 Fresh cement mortar composition
  5.4 Fresh cement mortar layer thickness
  5.5 Pipe ends
  5.6 Appearance of cured cement mortar coating
  5.7 Thickness of cured cement mortar coating
  5.8 Repairs
  5.9 Marking
6 Performance requirements
  6.1 Cement mortar Constituents
      6.1.1 Cement
      6.1.2 Sand
      6.1.3 Fibres
      6.1.4 Surface tissue
      6.1.5 Organic components
  6.2 Bond strength
  6.3 Impact resistance
7 Test methods
  7.1 Routine tests
      7.1.1 Zinc coating
      7.1.2 Primer
      7.1.3 Fresh cement mortar composition
      7.1.4 Thickness of the cement mortar layer
      7.1.5 Pipe ends
      7.1.6 Appearance and continuity of cured cement
            mortar coating
      7.1.7 Thickness of the cured cement mortar coating
      7.1.8 Repairs
      7.1.9 Marking
  7.2 Performance tests
      7.2.1 Constituents
      7.2.2 Bond strength
      7.2.3 Impact strength
Annex A (informative) - Quality assurance
      A.1 General
      A.2 Performance test
      A.3 Quality assessment system
Annex B (informative) - Application process
      B.1 Coating process
          B.1.1 Temperature during work
          B.1.2 Application of zinc coating
          B.1.3 Application of primer
      B.2 Application of cement mortar
          B.2.1 Application with primer
          B.2.2 Application without primer
Annex C (informative) - Explanatory notes
Annex D (informative) - Calculation of fresh cement mortar
        composition
      D.1 General
      D.2 Sampling
      D.3 Determination of the content of sand and fibres
      D.4 Determination of the fibre content
Bibliography

Describes the requirements and test methods applicable to factory applied cement mortar coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 degrees C, and for soil conditions according to Annex D.2 of EN 545:2006.

Committee
CT 700
DocumentType
Test Method
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current

Standards Relationship
EN 15542:2008 Identical

ISO 3310-1:2016 Test sieves Technical requirements and testing Part 1: Test sieves of metal wire cloth
EN 197-1:2011 Cement - Part 1: Composition, specifications and conformity criteria for common cements
ISO/IEC 17021:2011 Conformity assessment Requirements for bodies providing audit and certification of management systems
EN 598:2007+A1:2009 Ductile iron pipes, fittings, accessories and their joints for sewerage applications - Requirements and test methods
EN 197-2:2014 Cement - Part 2: Conformity evaluation
EN ISO 527-2:2012 Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:2012)
EN 14020-1:2002 Reinforcements - Specification for textile glass rovings - Part 1: Designation
ISO 2591-1:1988 Test sieving — Part 1: Methods using test sieves of woven wire cloth and perforated metal plate
EN ISO 527-1:2012 Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:2012)
EN 969:2009 Ductile iron pipes, fittings, accessories and their joints for gas pipelines - Requirements and test methods
ISO 527-2:2012 Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics
ISO 695:1991 Glass — Resistance to attack by a boiling aqueous solution of mixed alkali — Method of test and classification
ISO 4624:2016 Paints and varnishes — Pull-off test for adhesion
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
ISO 1183-1:2012 Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method
EN ISO 4624:2016 Paints and varnishes - Pull-off test for adhesion (ISO 4624:2016)
ISO 9001:2015 Quality management systems — Requirements
EN ISO/IEC 17021:2011 Conformity assessment - Requirements for bodies providing audit and certification of management systems (ISO/IEC 17021:2011)
EN 545:2010 Ductile iron pipes, fittings, accessories and their joints for water pipelines - Requirements and test methods
ISO 719:1985 Glass Hydrolytic resistance of glass grains at 98 degrees C Method of test and classification
EN ISO 1183-1:2012 Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012)
EN 14020-2:2002 Reinforcements - Specification for textile glass rovings - Part 2: Methods of test and general requirements
ISO 527-1:2012 Plastics Determination of tensile properties Part 1: General principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.