UNI EN ISO 8359 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
OXYGEN CONCENTRATORS FOR MEDICAL USE - SAFETY REQUIREMENTS
13-09-2022
01-01-2012
Foreword
Section 1 - General
Section 2 - Safety requirements
Section 3 - Protection against electric shock hazards
Section 4 - Protection against mechanical hazards
Section 5 - Protection against hazards from unwanted or
excessive radiation
Section 6 - Protection against hazards of explosions in
medically used rooms
Section 7 - Protection against excessive temperatures and
other safety hazards
Section 8 - Accuracy of operating data and protection against
hazardous output
Section 9 - Abnormal operation and fault conditions;
environmental tests
Section 10 - Constructional requirements
Section 11 - Additional clauses
Annexes
Annex N (normative) - Test apparatus
Annex P (informative) - Rationale statement
Annex Q (informative) - Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 93/42/EEC
Defines safety requirements for continuous-flow oxygen concentrators.
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN ISO 8359:2009 | Identical |
SN EN ISO 8359 : 2009 AMD 1 2012 | Identical |
NEN EN ISO 8359 : 2009 AMD 1 2012 | Identical |
DIN EN ISO 8359:2009-08 | Identical |
ISO 8359:1996 | Identical |
NBN EN ISO 8359 : 2009 AMD 1 2012 | Identical |
I.S. EN ISO 8359:2009 | Identical |
NF EN ISO 8359 : 2009 AMD 1 2012 | Identical |
BS EN ISO 8359 : 2009 | Identical |
NS EN ISO 8359 : 2009 AMD 1 2012 | Identical |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
ISO 9703-1:1992 | Anaesthesia and respiratory care alarm signals Part 1: Visual alarm signals |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
NFPA 53 : 2016 | MATERIALS, EQUIPMENT, AND SYSTEMS USED IN OXYGEN-ENRICHED ATMOSPHERES |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
ISO 9703-2:1994 | Anaesthesia and respiratory care alarm signals — Part 2: Auditory alarm signals |