VDE 0830-7-2-1 : 1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: BLACK AND WHITE CAMERAS
12-01-2013
01-08-2007
Einleitung
1 Anwendungsbereich
2 Normative Verweisungen und Bibliographie
2.1 Normative Verweisungen
2.2 Bibliographie
3 Definitionen und Abkürzungen
3.1 Definitionen
3.2 Abkürzungen
4 Anforderungen
4.1 Bildwandler
4.2 Video-Signalausgang
4.3 Automatische Verstärkungsregelung (AGC)
4.4 Gamma-Korrektur
4.5 Empfindlichkeit und Signal-Störabstand
4.6 Maximale Auflösung
4.7 Kontrast-Übertragungsfunktion (CTF)
4.8 Schwarzwert
4.9 Automatischer Lichtregelungs(ALC)-Bereich
4.10 Synchronisation
4.11 Geometrische Verzerrungen
4.12 Abbildungsverhältnis
4.13 Energieversorgung
4.14 Elektrische Sicherheit
4.15 Kameraobjektiv-Befestigung
4.16 Kamera-Befestigung
4.17 Elektromagnetische Verträglichkeit
4.18 Umweltbedingungen
5 Prüfbedingungen
5.1 Einleitung
5.2 Prüfmitte
5.3 Laborbedingungen
6 Prüfungen der Leistungsmerkmale
6.1 Video-Signalausgang
6.2 Gamma-Korrektur
6.3 Empfindlichkeit
6.4 Signal-Störabstand
6.5 Maximale Auflösung
6.6 Automatische Verstärkungsregelung
6.7 Kontrast-Übertragungsfunktion (CTF)
6.8 Schwarzwert
6.9 Synchronisation
6.10 Geometrische Verzerrungen
7 Umweltprüfungen
7.1 Einleitung
7.2 Auswahl des Prüfscharfegrades
7.3 Trockene Wärme (Betriebsprüfung)
7.4 Trockene Wärme (Dauerprüfung)
7.5 Kälte (Betriebsprüfung)
7.6 Feuchte Wärme, konstant (Betriebsprüfung)
7.7 Feuchte Wärme, konstant (Dauerprüfung)
7.8 Feuchte Wärme, zyklisch (Betriebsprüfung)
7.9 Feuchte Wärme, zyklisch (Dauerprüfung)
7.10 Wasser (Dauerprüfung)
7.11 Schwefeldioxid (SO[2])-Korrosion (Dauerprüfung)
7.12 Salznebel, zyklisch (Dauerprüfung)
7.13 Schocken (Betriebsprüfung)
7.14 Schwingen, sinusförmig (Betriebsprüfung)
7.15 Schwingen, sinusförmig (Dauerprüfung)
7.16 Staubdichtigkeit (Dauerprüfung)
8 Dokumentation
9 Kennzeichnung und Beschriftung
Anhang A (informativ) Szenenbeleuchtung im Verhältnis
zur Lichtempfindlichkeit der Kamera
Anhang B (normativ) CCTV-Prüftafeln
Diese Norm beschreibt die minimalen Anforderungen für die Spezifikation und Prüfung von Schwarzweiss- CCTV-Kameras, die in CCTV-Überwachungssystemen für Sicherheits- und Überwachungsanwendungen verwendet werden. Möglicherweise werden Kameras installiert, die zusätzliche Merkmale mit der Absicht aufweisen, ihren Funktionsumfang zu steigern, um den Bediener mit verlässlichen und leicht erkennbaren Informationen zu versorgen. Diese Merkmale werden in dieser Norm nicht behandelt, doch es liegt in der Verantwortung des Festlegenden, die Eignung dieser Merkmale für die Anwendung zu bestimmen. Sabotageschutz und -überwachung werden von dieser Norm nicht abgedeckt. Wenn als Systemanforderung definiert, müssen die Massnahmen für Sabotageschutz und Sabotageüberwachung angewendet werden, wie sie in der entsprechenden Systemnorm festgelegt sind.
| DocumentType |
Standard
|
| PublisherName |
Verband Deutscher Elektrotechniker
|
| Status |
Withdrawn
|
| Standards | Relationship |
| EN 50132-2-1 : 1997 | Identical |
| DIN EN 50132-2-1 : 1999 | Identical |
| DIN EN 50132-2-1 : 1999 | Corresponds |
| VDE 0830-7-7 : 2013 | ALARMANLAGEN - CCTV-UEBERWACHUNGSANLAGEN FUER SICHERUNGSANWENDUNGEN - TEIL 7: ANWENDUNGSREGELN |
| DIN EN 60068-2-2 : 1995 | ENVIRONMENTAL TESTING - PART 2-2: TESTS - TEST B: DRY HEAT |
| IEC 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
| DIN IEC 60068-2-3:1986-12 | ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TEST CA: DAMP HEAT, STEADY STATE |
| DIN IEC 60068-2-30:1986-09 | ELECTRICAL ENGINEERING - BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST DB AND GUIDANCE - DAMP HEAT, CYCLIC (12 + 12 HOUR CYCLE) |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
| VDE 0830-1-4 : 2015-04 | Alarm systems Part 4: Electromagnetic compatibility – Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems; |
| IEC 60950:1999 | Safety of information technology equipment |
| EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
| EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
| VDE 0860 : 2015 COR 1 2016 | AUDIO-, VIDEO- UND AEHNLICHE ELEKTRONISCHE GERAETE - SICHERHEITSANFORDERUNGEN (IEC 60065:2014, MODIFIZIERT) |
| DIN EN 60068-2-6 : 1996 | ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL) |
| VDE 0805 : 2001 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
| DIN EN 60068-2-1 : 1995 | ENVIRONMENTAL TESTING - PART 2-1: TESTS - TEST A: COLD |
| DIN EN 60068-2-27 : 1995 | ENVIRONMENTAL TESTING - PART 2-27: TESTS - TEST EA AND GUIDANCE: SHOCK |
| DIN EN 50132-7 : 2013 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 7: APPLICATION GUIDELINES |
| EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| DIN EN 60068-1 : 2015 | ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE (IEC 60068-1:2013) |
| IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| DIN EN 50130-4 : 2015-04 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
| DIN EN 60065 : 2015 COR 1 2016 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014, MODIFIED) |
| IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
| DIN IEC 60068-2-42:1985-08 | ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST KC - SULPHUR DIOXIDE SO[2] (HIGH CONCENTRATION) FOR ELECTRICAL CONTACTS AND CONNECTIONS |
| EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
| IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
| EN 50132-7:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines |
| DIN IEC 60068-2-18:1991-04 | ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TEST R AND GUIDANCE: WATER |
| IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |