• There are no items in your cart

Z316.8-18

Current

Current

The latest, up-to-date edition.

Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions

Available format(s)

Hardcopy , PDF

Language(s)

French, English

Published date

01-01-2018

€67.30
Excluding VAT

Preface
Introduction
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 Quality management system
5 Pre-validation - Determination of
                   test requirements
6 Validation experiments
7 Post-validation
Annex A (informative) - Recommended resources
Annex B (informative) - Process overview

Preface This is the first edition of CSA Z316.8, Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions. CSA Group gratefully acknowledges that the development of this Standard was made possible, in part, by the financial and in-kind support from the Canadian Agency for Drugs and Technologies in Health (CADTH), the Canadian Society for Medical Laboratory Science (CSMLS), Alere ULC, Siemens, and Roche. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard specifies the minimum requirements and best practices for the development, validation, and use of laboratory-developed tests in clinical and research laboratories for the screening, diagnosis, and management of clinical conditions. It does not provide specific details on how to achieve these requirements since they are provided in many other sources which are considered current best practice. References to these resources will be provided in this Standard. Note: See also Annex A for recommended resources. 1.2 Inclusions The Standard is intended to be used by organizations and individuals that are developing LDTs for the purpose of providing results that can be used in the screening, diagnosis, or management of clinical conditions. 1.3 Exclusions This Standard does not apply to the following: a) tests developed in-house but distributed outside of the laboratory; Note: Tests distributed outside of the laboratory fall outside the definition of \"laboratory-developed test\". These are considered to be commercially distributed IVDDs and are regulated by Health Canada under the Medical Devices Regulations. b) LDTs that are developed by a laboratory or manufacturer solely for RUO or IUO (i.e., where there is no reporting of patient results); and c) accredited, non-clinical laboratories which have their own standard for development, validation, and use of LDTs. The Standard does not apply to laboratory-developed tests that are developed by a laboratory for RUO/ IUO until such time that the test becomes applied to clinical testing and has undergone suitable validation according to the requirements in this Standard. Notes: 1) The RUO/IUO labeling is meant to serve as a warning to prevent such products from being used in clinical diagnosis or patient management. However, clinical laboratories can validate tests using RUO reagents or components through their own procedures as described in this Standard, and subsequently offer it for clinical diagnostic use as a laboratory-developed test once validated. 2) Refer also to the Distribution of In Vitro Diagnostic Products Labeled for Research Use Only or Investigational Use Only. Guidance for Industry and Food and Drug Administration Staff document issued on November 25, 2013, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Office of In Vitro Diagnostic Device Evaluation and Safety. 1.4 Terminology In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

DocumentType
Standard
ISBN
978-1-4883-1576-3
Pages
0
PublisherName
Canadian Standards Association
Status
Current

Preface This is the first edition of CSA Z316.8, Requirements for the design, development, and validation of laboratory-developed tests used for the screening, diagnosis, and management of clinical conditions. CSA Group gratefully acknowledges that the development of this Standard was made possible, in part, by the financial and in-kind support from the Canadian Agency for Drugs and Technologies in Health (CADTH), the Canadian Society for Medical Laboratory Science (CSMLS), Alere ULC, Siemens, and Roche. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard specifies the minimum requirements and best practices for the development, validation, and use of laboratory-developed tests in clinical and research laboratories for the screening, diagnosis, and management of clinical conditions. It does not provide specific details on how to achieve these requirements since they are provided in many other sources which are considered current best practice. References to these resources will be provided in this Standard. Note: See also Annex A for recommended resources. 1.2 Inclusions The Standard is intended to be used by organizations and individuals that are developing LDTs for the purpose of providing results that can be used in the screening, diagnosis, or management of clinical conditions. 1.3 Exclusions This Standard does not apply to the following: a) tests developed in-house but distributed outside of the laboratory; Note: Tests distributed outside of the laboratory fall outside the definition of \"laboratory-developed test\". These are considered to be commercially distributed IVDDs and are regulated by Health Canada under the Medical Devices Regulations. b) LDTs that are developed by a laboratory or manufacturer solely for RUO or IUO (i.e., where there is no reporting of patient results); and c) accredited, non-clinical laboratories which have their own standard for development, validation, and use of LDTs. The Standard does not apply to laboratory-developed tests that are developed by a laboratory for RUO/ IUO until such time that the test becomes applied to clinical testing and has undergone suitable validation according to the requirements in this Standard. Notes: 1) The RUO/IUO labeling is meant to serve as a warning to prevent such products from being used in clinical diagnosis or patient management. However, clinical laboratories can validate tests using RUO reagents or components through their own procedures as described in this Standard, and subsequently offer it for clinical diagnostic use as a laboratory-developed test once validated. 2) Refer also to the Distribution of In Vitro Diagnostic Products Labeled for Research Use Only or Investigational Use Only. Guidance for Industry and Food and Drug Administration Staff document issued on November 25, 2013, U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Office of In Vitro Diagnostic Device Evaluation and Safety. 1.4 Terminology In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
ISO 18113-1:2009 In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 1: Terms, definitions and general requirements
ISO 15189:2012 Medical laboratories — Requirements for quality and competence
ISO 17511:2003 In vitro diagnostic medical devices Measurement of quantities in biological samples Metrological traceability of values assigned to calibrators and control materials
ISO 14971-1:1998 Medical devices Risk management Part 1: Application of risk analysis
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.