English
1 Scope and object
2 Normative references
3 Terms and definitions
3.1 General
3.2 Definitions
3.3 Quantities and units
4 General requirements
4.1 General characteristics
4.2 Physical Configuration
4.3 Basic Information
4.4 Operating modes
4.5 Maintenance/Calibration
4.6 Communication interface
4.7 User interface
4.8 Markings
4.9 Power supply
4.10 Protection of Switches
4.11 Display units
4.12 Effective range of measurement
4.13 Alarms
4.14 Explosive atmospheres
4.15 Indication features
5 General test procedure
5.1 Nature of test
5.2 Reference conditions and standard test conditions
5.3 Statistical fluctuations
6 Radiation tests
6.1 Rate of false source indication alarm
6.2 Alarm and response time
6.3 Neutron alarm in the presence of photons
6.4 Over-range characteristics for neutron alarm
6.5 Personal protection alarm
6.6 Warm-up time
7 Environmental, mechanical and electrical performance
requirements
7.1 Temperature
7.2 Humidity
7.3 Cold temperature start-up
7.4 Dust and moisture resistance
7.5 Mechanical
7.6 Impact (Microphonics)
7.7 Battery requirements
7.8 Electrostatic discharge
7.9 Radio Frequency (RF)
7.10 Radiated emissions
7.11 Conducted immunity
7.12 Magnetic fields
8 Documentation
8.1 Type test report
8.2 Certificate
8.3 Operation and maintenance manual
Committee |
NCE/2
|
DocumentType |
Draft
|
Pages |
27
|
PublisherName |
British Standards Institution
|
Status |
Current
|
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
IEC 62244:2006 | Radiation protection instrumentation - Installed radiation monitors for the detection of radioactive and special nuclear materials at national borders |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
IEC 61005:2014 | Radiation protection instrumentation - Neutron ambient dose equivalent (rate) meters |
IEC 62401:2007 | Radiation protection instrumentation - Alarming personal radiation devices (PRD) for detection of illicit trafficking of radioactive material |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
IEC 62327:2006 | Radiation protection instrumentation - Hand-held instruments for the detection and identification of radionuclides and for the indication of ambient dose equivalent rate from photon radiation |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
IEC 62022:2004 | Installed monitors for the control and detection of gamma radiations contained in recyclable or non-recyclable materials transported by vehicles |
ISO 8529-2:2000 | Reference neutron radiations Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 8529-1:2001 | Reference neutron radiations Part 1: Characteristics and methods of production |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 61526:2010 | Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.