FOREWORD
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 DLL - PhL interface
6 Systems management - PhL interface
7 DCE independent sublayer (DIS)
8 DTE - DCE interface and MIS-specific functions
9 Medium dependent sublayer (MDS)
10 MDS - MAU interface
11 Types 1 and 7: Medium attachment unit: voltage
mode, linear-bus-topology 150 omega twisted-pair
wire medium
12 Types 1 and 3: Medium attachment unit: 31,25 kbit/s,
voltage-mode with low-power option, bus- and tree-topology,
100 omega wire medium
13 Type 1: Medium attachment unit: current mode,
twisted-pair wire medium
14 Type 1: Medium attachment unit: current mode
(1 A), twisted-pair wire medium
15 Types 1 and 7: Medium attachment unit: dual-fiber
optical media
16 Type 1: Medium attachment unit: 31,25 kbit/s,
single-fiber optical medium
17 Type 1: Medium attachment unit: radio signaling
18 Type 2: Medium attachment unit: 5 Mbit/s, voltage-mode,
coaxial wire medium
19 Type 2: Medium attachment unit: 5 Mbit/s, optical
medium
20 Type 2: Medium attachment unit: network access
port (NAP)
21 Type 3: Medium attachment unit: synchronous transmission,
31,25 kbit/s, voltage mode, wire medium
22 Type 3: Medium attachment unit: asynchronous
transmission, wire medium
23 Type 3: Medium attachment unit: asynchronous
transmission, optical medium
24 Type 4: Medium attachment unit: RS-485
25 Type 4: Medium attachment unit: RS-232
26 Type 6: This clause has been removed
27 Type 8: Medium attachment unit: twisted-pair wire
medium
28 Type 8: Medium attachment unit: optical media
29 Type 12: Medium attachment unit: electrical medium
30 Type 16: Medium attachment unit: optical fiber medium
at 2, 4, 8 and 16 Mbit/s
31 Type 18: Medium attachment unit: basic medium
32 Type 18: Medium attachment unit: powered medium
Annex A (normative) - Type 1: Connector specification
Annex B (informative) - Types 1 and 3: Cable specifications
and trunk and spur lengths for the 31,25 kbit/s
voltage-mode MAU
Annex C (informative) - Types 1 and 7: Optical passive stars
Annex D (informative) - Types 1 and 7: Star topology
Annex E (informative) - Type 1: Alternate fibers
Annex F (normative) - Type 2: Connector specification
Annex G (normative) - Type 2: Repeater machine sublayers
(RM, RRM) and redundant PhLs
Annex H (informative) - Type 2: Reference design examples
Annex I (normative) - Type 3: Connector specification
Annex J (normative) - Type 3: Redundancy of PhL and medium
Annex K (normative) - Type 3: Optical network topology
Annex L (informative) - Type 3: Reference design examples for
asynchronous transmission, wire medium, intrinsically
safe
Annex M (normative) - Type 8: Connector specification
Annex N (normative) - Type 16: Connector specification
Annex O (normative) - Type 16: Optical network topology
Annex P (informative) - Type 16: Reference design example
Annex Q (normative) - Type 18: Connector specification
Annex R (normative) - Type 18: Media cable specifications
Bibliography
BS EN 61158-2
Committee |
AMT/7
|
DocumentType |
Draft
|
Pages |
407
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 60050-731:1991 | International Electrotechnical Vocabulary (IEV) - Part 731: Optical fibre communication |
IEC 60807-3:1990 | Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
TIA 232 : F1997(R2012) | INTERFACE BETWEEN DATA TERMINAL EQUIPMENT AND DATA CIRCUIT-TERMINATING EQUIPMENT EMPLOYING SERIAL BINARY DATA INTERCHANGE |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
ISO/IEC 8886:1996 | Information technology Open Systems Interconnection Data link service definition |
IEC 61596:1995 | Magnetic oxide EP-cores and associated parts for use in inductors and transformers - Dimensions |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
IEC 60874-10-1:1997 | Connectors for optical fibres and cables - Part 10-1: Detail specification for fibre optic connector type BFOC/2,5 terminated to multimode fibre type A1 |
ISO/IEC 10731:1994 | Information technology Open Systems Interconnection Basic Reference Model Conventions for the definition of OSI services |
IEC 61754-2:1996 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO/TR 8509:1987 | Information processing systems Open Systems Interconnection Service conventions |
IEC 61491:2002 | Electrical equipment of industrial machines - Serial data link for real-time communication between controls and drives |
IEC 60079-27:2008 | Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) |
IEC 61754-13:2006 | Fibre optic connector interfaces - Part 13: Type FC-PC connector |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
ISO/IEC 10022:1996 | Information technology Open Systems Interconnection Physical Service Definition |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 60169-8:1978 | Radio-frequency connectors. Part 8: R.F. coaxial connectors with inner diameter of outer conductor 6.5 mm (0.256 in) with bayonet lock - Characteristic impedance 50 ohms (Type BNC) |
IEC 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specificationn - Type 3 elements |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
TIA 485 : A1998(R2012) | ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS |
ISO/IEC 8482:1993 | Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.