• Shopping Cart
    There are no items in your cart

12/30248745 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE

Available format(s)

Hardcopy , PDF

Superseded date

30-09-2012

Superseded by

BS 7211:2012

Language(s)

English

€23.37
Excluding VAT

1 Scope
2 Normative references
3 Terms and definitions
4 Rated Voltage
5 Construction
6 Conductors
7 Insulation
8 Identification of cores
9 Multi-core circular cables
10 Optional extruded inner covering
11 Sheath
12 Cable marking and additional information
13 Schedule of tests
14 Test conditions
15 Routine tests
16 Sample tests
17 Type tests
Annexes
Annex A (informative) - Coding cross references
Annex B (informative) - Traditional UK cables transferred
        to BS EN 50525
Annex C (informative) - Guide to use
Annex D (normative) - Compatibility test
Annex E (normative) - Method of test for voltage withstand
Annex F (informative) - Notes on type tests
Bibliography

BS 7211.

Committee
GEL/20/17
DocumentType
Draft
Pages
35
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Procedure
BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
BS 6469-99.1(1992) : 1992 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - PART 99: TEST METHODS USED IN THE UNITED KINGDOM BUT NOT SPECIFIED IN BS EN 60811 - SECTION 99.1: NON-ELECTRICAL TESTS
BS EN 60228:2005 Conductors of insulated cables
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
BS EN 60332-3-24:2009 Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C
BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
HD 308 S2:2001 Identification of cores in cables and flexible cords
BS EN 50356:2002 Method for spark testing of cables
BS 7540-1:2005 Electric cables. Guide to use for cables with a rated voltage not exceeding 450/750 V General guidance
BS EN 50395 : 2005 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
BS EN 50266-2-4:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C
BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.