17/30331680 DC : 0
NA
Status of Standard is Unknown
BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS
Hardcopy , PDF
English
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols (and abbreviated terms)
5 Approach to selecting appropriate condition monitoring
techniques
6 Power transformer types
7 Power transformer failure mode analysis
8 Range of techniques
9 Overview of techniques for condition monitoring power
transformers
10 Establishing the programme
Annex A (informative) - Factors influencing the life of paper-based
insulation and the role of transformer oil analysis/dissolved
gas analysis (DGA)
Annex B (informative) - Example of typical condition monitoring
programme - output as a result of use of this document
Annex C (informative) - Failure mode and symptoms
analysis (FMSA)
Bibliography
BS ISO 18095.
Committee |
GME/21/7
|
DocumentType |
Draft
|
Pages |
59
|
PublisherName |
British Standards Institution
|
Status |
NA
|
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC 62021-1:2003 | Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration |
IEC 62021-2:2007 | Insulating liquids - Determination of acidity - Part 2: Colourimetric titration |
IEEE 62-1995 | IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors |
IEC 60422:2013 | Mineral insulating oils in electrical equipment - Supervision and maintenance guidance |
IEC 60156:1995 | Insulating liquids - Determination of the breakdown voltage at power frequency - Test method |
IEC 60599:2015 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-18:2012 | Power transformers - Part 18: Measurement of frequency response |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEEE C57.149-2012 | IEEE Guide for the Application and Interpretation of Frequency Response Analysis for Oil-Immersed Transformers |
IEC 62535:2008 | Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil |
IEEE C57.155-2014 | IEEE Guide for Interpretation of Gases Generated in Natural Ester and Synthetic Ester-Immersed Transformers |
IEEE C57.19.00 : 2004 | GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEEE C57.104-2008 | IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers |
IEC 60970:2007 | Insulating liquids - Methods for counting and sizing particles |
ISO 13372:2004 | Condition monitoring and diagnostics of machines Vocabulary |
IEEE C57.143-2012 | IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
ISO 29821-1:2011 | Condition monitoring and diagnostics of machines Ultrasound Part 1: General guidelines |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEC 62697-1:2012 | Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids - Part 1: Test method for quantitative determination of dibenzyldisulfide (DBDS) |
IEC 60814:1997 | Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60247:2004 | Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity |
ISO 2049:1996 | Petroleum products Determination of colour (ASTM scale) |
IEC 61619:1997 | Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography |
IEEE C57.12.10-2010 REDLINE | IEEE Standard Requirements for Liquid-Immersed Power Transformers |
ISO 18434-1:2008 | Condition monitoring and diagnostics of machines — Thermography — Part 1: General procedures |
IEEE C57.152-2013 | IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors |
ISO 17359:2011 | Condition monitoring and diagnostics of machines General guidelines |
IEC 60214-2:2004 | Tap-changers - Part 2: Application guide |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.