• 17/30331680 DC : 0

    NA Status of Standard is Unknown

    BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date: 

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols (and abbreviated terms)
    5 Approach to selecting appropriate condition monitoring
       techniques
    6 Power transformer types
    7 Power transformer failure mode analysis
    8 Range of techniques
    9 Overview of techniques for condition monitoring power
       transformers
    10 Establishing the programme
    Annex A (informative) - Factors influencing the life of paper-based
            insulation and the role of transformer oil analysis/dissolved
            gas analysis (DGA)
    Annex B (informative) - Example of typical condition monitoring
            programme - output as a result of use of this document
    Annex C (informative) - Failure mode and symptoms
            analysis (FMSA)
    Bibliography

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee GME/21/7
    Document Type Draft
    Publisher British Standards Institution
    Status NA

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
    IEC 62021-1:2003 Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration
    IEC 62021-2:2007 Insulating liquids - Determination of acidity - Part 2: Colourimetric titration
    IEEE 62-1995 IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors
    IEC 60422:2013 Mineral insulating oils in electrical equipment - Supervision and maintenance guidance
    IEC 60156:1995 Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
    IEC 60599:2015 Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
    IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
    IEC 60076-18:2012 Power transformers - Part 18: Measurement of frequency response
    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    IEEE C57.149-2012 IEEE Guide for the Application and Interpretation of Frequency Response Analysis for Oil-Immersed Transformers
    IEC 62535:2008 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil
    IEEE C57.155-2014 IEEE Guide for Interpretation of Gases Generated in Natural Ester and Synthetic Ester-Immersed Transformers
    IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
    IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
    IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
    IEC 60076-8:1997 Power transformers - Part 8: Application guide
    IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
    IEEE C57.104-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers
    IEC 60970:2007 Insulating liquids - Methods for counting and sizing particles
    ISO 13372:2004 Condition monitoring and diagnostics of machines Vocabulary
    IEEE C57.143-2012 IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    ISO 29821-1:2011 Condition monitoring and diagnostics of machines Ultrasound Part 1: General guidelines
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 60076-6:2007 Power transformers - Part 6: Reactors
    IEC 62697-1:2012 Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids - Part 1: Test method for quantitative determination of dibenzyldisulfide (DBDS)
    IEC 60814:1997 Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration
    IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    IEC 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
    ISO 2049:1996 Petroleum products Determination of colour (ASTM scale)
    IEC 61619:1997 Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography
    IEEE C57.12.10-2010 REDLINE IEEE Standard Requirements for Liquid-Immersed Power Transformers
    ISO 18434-1:2008 Condition monitoring and diagnostics of machines — Thermography — Part 1: General procedures
    IEEE C57.152-2013 IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors
    ISO 17359:2011 Condition monitoring and diagnostics of machines General guidelines
    IEC 60214-2:2004 Tap-changers - Part 2: Application guide
    IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective