AS 1603.8-1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Automatic fire detection and alarm systems Multi-point aspirated smoke detectors (Reconfirmed 2016)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
07-01-2020
English
05-02-1996
Specifies the requirements for the design, construction and performance of aspirated system type smoke detectors, used in automatic fire detection and alarm systems.
Committee |
FP/2
|
DocumentType |
Standard
|
ISBN |
0 7337 0266 X
|
Pages |
13
|
ProductNote |
Reconfirmed 08/07/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 08/07/2016
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard specifies requirements for the design, construction and performance of aspirated system type smoke detectors used in automatic fire detection and alarm systems. This Standard covers multi-point aspirated systems and their associated detector and control facilities. Single-point detectors installed with probes in air-handling ducts are not included.NOTE: Some of the requirements of this Standard are more onerous than those nominated in AS 1603.2 point-type smoke detectors as one multi-point aspirated detector can be installed to cover the total area nominated for one AZF in AS 1670.
First published as AS 1603.8-1996.
AS 2362.6-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Static discharge test |
AS 2362.13-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Corrosion test |
AS 1670-1986 | Automatic fire detection and alarm systems - System design, installation, and commissioning |
AS 2484.2-1991 | Fire - Glossary of terms Fire protection and firefighting equipment |
AS 2362.11-2002 | Fire detection, warning, control and intercom systems Methods of test - Damp heat test |
AS 1159-1988 | Polyethylene pipes for pressure applications |
AS 2362.17-2001 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Sensitivity test (Reconfirmed 2016) |
AS 2362.10-2002 | Fire detection, warning, control and intercom systems - Methods of test Low temperature test (Reconfirmed 2016) |
AS 2362.8-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Impulse voltage withstand test |
AS 2362.19-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Dust test |
AS/NZS 3121:2002 | Approval and test specification - Insulating mouldings (Reconfirmed 2020) |
AS 2362.11-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Damp heat test |
AS 2546.1-1982 | Printed boards General requirements and test methods |
AS 2362.13-2002 | Fire detection, warning, control and intercom systems Methods of test - Corrosion test (Reconfirmed 2016) |
AS 2053-1984 | Non-metallic conduits and fittings |
AS 3100-1990 | Approval and test specification - General requirements for electrical equipment |
AS 2362.5-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Insulation resistance test |
AS 2362.12-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Dry heat test |
AS 2362.7-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Electromagnetic interference test |
AS 2706-1984 | Numerical values - Rounding and interpretation of limiting values |
AS 2362.4-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Voltage stability test |
AS 2362.15-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Vibration test |
AS 3121-1992 | Approval and test specification - Insulating mouldings |
AS 2362.25-2004 | Fire detection, warning, control and intercom systems Methods of test - Indicator visibility test (Reconfirmed 2016) |
AS 2362.19-2002 | Fire detection, warning, control and intercom systems Methods of test - Dust test (Reconfirmed 2016) |
AS 2362.12-2002 | Fire detection, warning, control and intercom systems Methods of test - Dry heat test (Reconfirmed 2016) |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 2362.9-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - High frequency disturbance test |
AS 2362.25-1996 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Indicator visibility test |
AS 2362.16-2002 | Fire detection, warning, control and intercom systems Methods of test - Impact test (Reconfirmed 2016) |
AS 2362.16-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Impact test |
AS 2362.17-1993 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Sensitivity test |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS 1603.4-1987 | Automatic fire detection and alarm systems Control and indicating equipment |
AS 1603.2-1997 | Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016) |
AS 2211-1991 | Laser safety |
AS 2362.15-2002 | Fire detection, warning, control and intercom systems Methods of test - Vibration test (Reconfirmed 2016) |
AS 2362.10-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Low temperature test |
AS 2706-2003 | Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018) |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |
AS 3007.3-2004 | Electrical installations - Surface mines and associated processing plant General requirements for equipment and ancillaries |
AS 4825-2011 | Tunnel fire safety |
AS 2665-2001 | Smoke/heat venting systems - Design, installation and commissioning (Reconfirmed 2016) |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS 1670.1-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire |
AS 4428.9-1996 | Fire detection, warning, control and intercom systems - Control and indicating equipment - Requirements for wire-free alarm zone circuits |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.