AS 2047-1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Windows in buildings - Selection and installation
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-07-2024
05-06-1999
Specifies requirements for materials, construction, installation and glazing for windows, sliding doors, adjustable glass louvres, shopfronts, and window walls with one-piece framing elements.
Committee |
BD/21
|
DocumentType |
Standard
|
ISBN |
0 7337 2720 4
|
Pages |
51
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements, materials, construction, installationand glazing for - (a) windows;(b) sliding glazed doors;(c) adjustable louvres; (d) shopfronts; and (e) window walls with one-piece framing elements.NOTE: Window walls do not include curtain walls using stacked or vertically spliced framingsystems, manufactured from any material and installed in external walls of all classes of buildings.Throughout this standard the term ‘window(s)’ means window of any type, including louvre(s) and sliding door(s).NOTES:1 The window ratings, or classifications, differ from previous glass and window Standards due to the more accurate evaluation of the effect of wind conditions. They are based on either AS 1170.2, or the specific wind loading code developed for housing, i.e. AS 4055.2 See Appendix A for information on wind loads applicable to windows covered by this Standard.3 See Appendix B for alternative means of demonstrating compliance with this Standard.4 Prefabricated bay windows that incorporate sloped glass are classified as windows in external walls.5 Refer to AS/NZS 4284 for performance specification of building facade. Conformance to the requirements in AS/NZS 4284 will be deemed to satisfy the requirements of this Standard. However, sliding window sashes or doors will require the operating force test in accordance with AS 4420.3.6 The following are not covered by this Standard: (a) Hinged doors, including French and bi-fold doors. (b) Revolving glazed doors. (c) Fixed louvres. (d) Skylights and roof lights and windows in other than the vertical plane. (e) Windows in greenhouses and agricultural buildings. (f) Sliding doors without frames such as internal doors and shopfront doors. (g) Windows constructed on site and architectural one-off windows, which are not designtested. (h) Second-hand windows, re-used windows, replacement windows, or recycled windows. (i)Heritage windows, for heritage buildings as defined by the relevant State or Territory authority.
Originated in part as part of SAA Int. 318-1951.
Final edition AS 2147-1996 and AS 2147.2-1996.
AS 2047.1-1996 and AS 2047.2-1996 revised, amalgamated and redesignated AS 2047-1999.
Reissued incorporating Amendment No. 1 (January 2001).
Reissued incorporating Amendment No. 2 (June 2001).
AS 2331.3.1-2001 | Methods of test for metallic and related coatings Corrosion and related property tests - Neutral salt spray test (NSS test) (Reconfirmed 2017) |
AS 3715-1989 | Metal finishing - Thermoset powder coatings for architectural applications |
AS/NZS 1080.1:1997 | Timber - Methods of Test Moisture content |
AS/NZS 1865:1997 | Aluminium and aluminium alloys - Drawn wire, rod, bar and strip (Reconfirmed 2020) |
AS 1288-2006 | Glass in buildings - Selection and installation |
AS 1399-1990 | Guide to AS 1199 - Sampling procedures and tables for inspection by attributes |
AS 1199-1988 | Sampling procedures and tables for inspection by attributes |
HB 18.28-2005 | Conformity assessment - Guidance on a third-party certification system for products |
AS 1288-1994 | Glass in buildings - Selection and installation |
AS 4055-1992 | Wind loads for housing |
AS 1728-1975 | Types of timber surfaces |
AS 1231-2000 | Aluminium and aluminium alloys - Anodic oxidation coatings |
AS 1874-2000 | Aluminium and aluminium alloys - Ingots and castings (Reconfirmed 2018) |
AS/NZS 1665:2004 | Welding of aluminium structures (Reconfirmed 2016) |
AS 1789-1984 | Electroplated coatings - Zinc on iron or steel |
AS 1866:1997 | Aluminium and aluminium alloys - Extruded rod, bar, solid and hollow shapes (Reconfirmed 2020) |
AS 1866-1986 | Aluminium and aluminium alloys - Extruded rod, bar, solid and hollow shapes |
AS 3715-2002 | Metal finishing - Thermoset powder coatings for architectural applications of aluminium and aluminium alloys |
AS 1604-1997 | Timber - Preservative-treated - Sawn and round |
AS 1397-2001 | Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated |
AS/NZS ISO 9000.1:1994 | Quality management and quality assurance standards Guidelines for selection and use |
AS 1665-1992 | Welding of aluminium structures |
AS 1397-1993 | Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated |
AS 1167.2-1986 | Welding and brazing - Filler metals - Filler metal for welding |
AS 1449-1994 | Wrought alloy steels - Stainless and heat-resisting steel plate, sheet and strip |
AS/NZS 1605:1998 | Methods for sampling and analysing timber preservatives and preservative-treated timber |
AS 1170.2-1989 | Minimum design loads on structures (known as the SAA Loading Code) Wind loads |
AS/NZS 2904:1995 | Damp-proof courses and flashings |
AS 2331.3.1-1980 | Methods of test for metallic and related coatings Corrosion and related property tests - Neutral salt spray (NSS) test |
AS 4420.2-1996 | Windows - Methods of test - Deflection test |
AS/NZS 2098.2:1996 | Methods of test for veneer and plywood Bond quality of plywood (chisel test) |
AS 1650-1989 | Hot-dipped galvanized coatings on ferrous articles |
AS/NZS 4284:1995 | Testing of building facades |
AS 4055-2006 | Wind loads for housing |
AS 4420.5-1996 | Windows - Methods of test - Water penetration resistance test |
AS 4420.6-1996 | Windows - Methods of test - Ultimate strength test |
AS/NZS ISO 9004.1:1994 | Quality management and quality system elements Guidelines |
AS/NZS 4491:1997 | Timber - Glossary of terms in timber-related Standards (Reconfirmed 2016) |
AS/NZS 1167.2:1999 | Welding and brazing - Filler metals Filler metal for welding |
AS 1789-2003 | Electroplated zinc (electrogalvanized) coatings on ferrous articles (batch process) (Reconfirmed 2017) |
AS 1231-1985 | Aluminium and aluminium alloys - Anodized coatings for architectural applications |
AS/NZS 1170.2:2002 | Structural design actions Wind actions |
AS 1874-1988 | Aluminium and aluminium alloys - Ingots and castings |
AS/NZS 2098.2:2006 | Methods of test for veneer and plywood Bond quality of plywood (chisel test) |
AS/NZS 1664.2:1997 | Aluminium structures Allowable stress design (Reconfirmed 2020) |
AS 4420.3-1996 | Windows - Methods of test - Operating force test |
AS/NZS 1734:1997 | Aluminium and aluminium alloys - Flat sheet, coiled sheet and plate (Reconfirmed 2020) |
AS 4420.4-1996 | Windows - Methods of test - Air infiltration test |
AS 2754.2-1991 | Adhesives for timber and timber products - Polymer emulsion adhesives |
AS/NZS 4666:2000 | Insulating glass units |
AS 5040-2003 | Installation of security screen doors and window grilles (Reconfirmed 2016) |
AS 4085-1992 | Automatic sliding door assemblies |
AS 2021-2000 | Acoustics - Aircraft noise intrusion - Building siting and construction |
AS 5007-2007 | Powered doors for pedestrian access and egress (Reconfirmed 2018) |
AS 2796.2-2006 | Timber - Hardwood - Sawn and milled products Grade description |
AS 4290-2000 | Design and installation of Revolving doors |
AS 4785.2-2002 | Timber - Softwood - Sawn and milled products Grade description (Reconfirmed 2016) |
AS 1288-2006 | Glass in buildings - Selection and installation |
AS 4785.1-2002 | Timber - Softwood - Sawn and milled products Product specification (Reconfirmed 2016) |
AS/NZS 4290:1995 | Design and installation of revolving doors |
AS 1668.3-2001 | The use of ventilation and airconditioning in buildings Smoke control systems for large single compartments or smoke reservoirs |
HB 31-1992 | Handbook of building construction tolerances - Extracts from building products and structures Standards |
AS 2665-2001 | Smoke/heat venting systems - Design, installation and commissioning (Reconfirmed 2016) |
WS13-2012 | Finishing Timber Externally |
HB 125-2007 | The glass and glazing handbook (including guide to AS 1288, Glass in buildings - Selection and installation) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-