AS 2182-1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Sterilizers - Steam - Benchtop
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-1998
Specifies requirements for benchtop electrically heated sterilizers that generate saturated steam within the unit at selected temperatures up to and including 136 degrees Celsius. These sterilizers are intended for use in health care facilities, generally for the sterilization of instruments and utensils (wrapped and unwrapped). They are not suitable for the sterilization of fluids, unless the sterilizer also complies with the relevant requirements of AS 2192 for the sterilization of fluids. Guidance on information that should be supplied with enquiries and orders is given in an appendix.
Committee |
ME-003
|
DocumentType |
Standard
|
ISBN |
0 7337 2163 X
|
Pages |
22
|
ProductNote |
Withdrawn 30-01-2017.
|
PublisherName |
Standards Australia
|
Status |
Withdrawn
|
Supersedes |
This Standard specifies requirements for benchtop electrically heated sterilizers that generate saturated steam within the unit at selected temperatures up to and including 136°C.These sterilizers are intended for use in health care facilities, generally for the sterilization of instruments and utensils (wrapped and unwrapped).NOTES:1 Sterilizers complying with this Standard-(a) are not suitable for the sterilization of fluids, unless the sterilizer also complies with the relevant requirements of AS 2192 for the sterilization of fluids (see Appendix A);(b) if not provided with a drying stage, should not be used for the sterilization of wrapped instruments and porous loads (see Appendix B);(c) if provided with a drying stage, are suitable for the sterilization of wrapped instruments and porous loads;(d) should not be installed in any location where flammable anaesthetics or volatile liquids may be used (see AS 1169); and(e) have a water supply reservoir that is manually filled and does not require connection to mains plumbing.2 There are difficulties in sterilizing lubricated devices. In such cases, advice should be sought from AS 4187.3 General information on design capabilities is given in Appendix B.4 Guidance on quality of feed water for steam generation is given in Appendix C.5 Guidance on information that should be supplied with enquires and orders is given in Appendix D.6 Standards for machines that wash, sterilize or dry medical equipment in health care facilities are listed in Appendix E.
First published as AS T56-1971.
Revised and redesignated AS 2182-1978.
Second edition 1981.
Third edition 1994.
Fourth edition 1998.
AS 1858.1-2003 | Electrodes and fluxes for submerged-arc welding Carbon steels and carbon-manganese steels |
AS 1858.1-1986 | Electrodes and fluxes for submerged-arc welding Carbon steels and carbon-manganese steels |
AS 1553.2-1987 | Covered electrodes for welding - Low and intermediate alloy steel electrodes for manual metal-arc welding of carbon steels and low and intermediate alloy steels |
AS 2162.1-1996 | Verification and use of volumetric apparatus General - Volumetric glassware |
AS 3100-1990 | Approval and test specification - General requirements for electrical equipment |
AS 1271-2003 | Safety valves, other valves, liquid level gauges and other fittings for boilers and unfired pressure vessels (Reconfirmed 2016) |
AS 1192-1982 | Electroplated coatings - Nickel and chromium |
AS 2971-2007 | Serially produced pressure vessels (Reconfirmed 2017) |
AS 3947.5.1-1995 | Low-voltage switchgear and controlgear Control circuit devices and switching elements - Electromechanical control circuit devices |
AS 1349-1986 | Bourdon tube pressure and vacuum gauges (Reconfirmed 2018) |
AS 2192-2002 | Sterilizers - Steam - Downward-displacement |
AS 1627.5-2003 | Metal finishing - Preparation and pretreatment of surfaces Pickling (Reconfirmed 2017) |
AS 1858.2-1989 | Electrodes and fluxes for submerged-arc welding - Low and intermediate alloy steels |
AS 1167.2-1986 | Welding and brazing - Filler metals - Filler metal for welding |
AS 1271-1997 | Safety valves, other valves, liquid level gauges, and other fittings for boilers and unfired pressure vessels |
AS 3789.2-1991 | Textiles for health care facilities and institutions Theatre linen and pre-packs |
AS 1722.1-1975 | Pipe threads of Whitworth form Sealing pipe threads (metric units) |
AS/NZS 1553.1:1995 | Covered electrodes for welding - Low carbon steel electrodes for manual metal-arc welding of carbon steels and carbon-manganese steels |
AS 1079.4-1988 | Packaging of items (sterile) for patient care Flexible packaging systems - For single use in hospitals |
AS 2192-1991 | Sterilizers - Steam - Downward displacement |
AS 1192-2004 | Electroplated coatings - Nickel and chromium (Reconfirmed 2017) |
AS/NZS 3947.5.1:2000 | Low-voltage switchgear and controlgear Control circuit devices and switching elements - Electromechanical control circuit devices |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 1553.2:1999 | Covered electrodes for welding - Low and intermediate alloy steel electrodes for manual metal-arc welding of carbon steels and low and intermediate alloy steels |
AS 1169-1982 | Minimizing of combustion hazards arising from the medical use of flammable anaesthetic agents |
HB 18.28-2005 | Conformity assessment - Guidance on a third-party certification system for products |
AS 3789.6-1996 | Textiles for health care facilities and institutions Fabric specifications |
AS 2203.1-1990 | Cored electrodes for arc-welding Ferritic steel electrodes |
AS/NZS 4187:2003 | Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities |
AS 4187-1998 | Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities |
AS 4260-1997 | High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018) |
AS 1627.5-1994 | Metal finishing - Preparation and pretreatment of surfaces - Pickling, descaling and oxide removal |
AS 1210-1997 | Pressure vessels |
AS 1210-1989 | |
AS/NZS 2717.1:1996 | Welding - Electrodes - Gas metal arc - Ferritic steel electrodes |
AS 1167.1-1993 | Welding and brazing - Filler metals Filler metal for brazing and braze welding |
AS 1650-1989 | Hot-dipped galvanized coatings on ferrous articles |
AS/NZS 2064:1997 | Limits and methods of measurement of electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) radiofrequency equipment |
AS 1449-1994 | Wrought alloy steels - Stainless and heat-resisting steel plate, sheet and strip |
AS/NZS 1167.1:2005 | Welding and brazing - Filler metals Filler metal for brazing and braze welding |
AS/NZS 1167.2:1999 | Welding and brazing - Filler metals Filler metal for welding |
AS 2717.2-1988 | Welding - Electrodes - Gas metal arc Aluminium and aluminium alloy |
AS 2971-1987 | Serially produced pressure vessels |
AS/NZS 4187:2003 | Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities |
AS 4276.1-1995 | Water microbiology General information and procedures |
AS 1766.1.1-1991 | Food microbiology General procedures and techniques - Samples, materials, equipment, laboratory practice |
AS/NZS 1200:2000 | Pressure equipment |
AS 4037-1992 | Boilers and pressure vessels - Examination and testing |
AS/NZS 4815:2001 | Office-based health care facilities not involved in complex patient procedures and processes - Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of the associated environment |
AS 4187-1994 | Code of practice for cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities |
AS/NZS 1200:1994 | Pressure equipment |
AS 4187-1998 | Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities |
AS 1079.1-1993 | Packaging of items (sterile) for patient care - Selection of packaging materials for goods undergoing sterilization |
AS/NZS 4815:2006 | Office-based health care facilities - Reprocessing of reusable medical and surgical instruments and equipment, and maintenance of the associated environment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.