• There are no items in your cart

AS 2941-2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fixed fire protection installations - Pumpset systems

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

26-06-2021

Superseded by

AS 2941-2008

Language(s)

English

Published date

01-01-2002

€143.89
Excluding VAT

1 - AS 2941-2002 FIXED FIRE PROTECTION INSTALLATIONS-PUMPSET SYSTEMS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Approved
8 - 1.4.2 Circulation relief
8 - 1.4.3 Controller
8 - 1.4.4 Discharge head (assembly)
8 - 1.4.5 Driver
8 - 1.4.6 Duty point
8 - 1.4.7 Dynamic shaft deflection
8 - 1.4.8 Efficiency
8 - 1.4.9 Hollow shaft
8 - 1.4.10 Inertia base
8 - 1.4.11 Maximum allowable casing working pressure
8 - 1.4.12 Maximum flow
9 - 1.4.13 Net positive suction head (NPSH)
9 - 1.4.14 Nominal size (DN)
9 - 1.4.15 Non-reverse ratchet
9 - 1.4.16 Oil-lubricated vertical turbine pump
9 - 1.4.17 Pressure-relief
9 - 1.4.18 Pumpset
9 - 1.4.19 Reference plane
9 - 1.4.20 Recirculation
9 - 1.4.21 Line shaft
9 - 1.4.22 Total discharge head
9 - 1.4.23 Total head (of a pump)
9 - 1.4.24 Total suction head
10 - 1.4.25 Velocity head
10 - 1.4.26 Water-lubricated vertical turbine pump
11 - SECTION 2 WATER SUPPLIES
11 - 2.1 GENERAL
11 - 2.2 ACCEPTABLE SOURCES OF SUPPLY
11 - 2.3 QUALITY OF WATER
11 - 2.4 FLOODED SUCTION
11 - 2.5 SUCTION
11 - 2.5.1 Suction size
11 - 2.5.2 Devices on suction piping
12 - SECTION 3 GENERAL REQUIREMENTS FOR FIRE PROTECTION PUMPSETS
12 - 3.1 PERFORMANCE CHARACTERISTICS
12 - 3.1.1 General
13 - 3.1.2 Sprinkler installation
15 - 3.2 TYPES OF PUMPS
15 - 3.2.1 Fire protection pumps
15 - 3.2.2 Ancillary pumps
17 - 3.3 TYPES OF DRIVERS
17 - 3.4 PUMP/DRIVER CONNECTION
17 - 3.5 BASEPLATE
17 - 3.6 PIPEWORK (see also Section 11)
17 - 3.6.1 Pressure rating
17 - 3.6.2 Pipe sizes
17 - 3.6.3 Reducers
17 - 3.6.4 Flanges
17 - 3.6.5 Threaded joints
18 - 3.6.6 Grooved or shouldered joints
18 - 3.7 VALVES
18 - 3.7.1 Non-return valve
18 - 3.7.2 Pump-isolating valves
18 - 3.7.3 Air release valves
18 - 3.7.4 Circulation relief valve
19 - 3.7.5 Pressure-relief valves
20 - 3.8 VISIBILITY OF DISCHARGE
20 - 3.9 PRESSURE GAUGES
20 - 3.9.1 General
20 - 3.9.2 Discharge pressure gauge
20 - 3.9.3 Suction pressure gauge
20 - 3.10 FLOW-MEASURING DEVICES
20 - 3.10.1 General
21 - 3.10.2 Capacity
21 - 3.10.3 Discharge
21 - 3.11 STARTING AND CONTROL
21 - 3.11.1 Arrangement
21 - 3.11.2 Warning sign
21 - 3.12 ELECTRICAL REQUIREMENTS
21 - 3.12.1 General
21 - 3.12.2 Power supply
21 - 3.13 MARKING
21 - 3.13.1 Method of marking
21 - 3.13.2 Pumpset
22 - 3.13.3 Pump
22 - 3.13.4 Driver
22 - 3.13.5 Fire pump controller
22 - 3.13.6 Battery
22 - 3.14 PUMPSET MANUALS
22 - 3.15 PUMPSET CONFIGURATIONS
29 - SECTION 4 SPECIFIC REQUIREMENTS FOR FIRE PROTECTION PUMPS
29 - 4.1 GENERAL
29 - 4.1.1 General design
29 - 4.1.2 Materials of construction
29 - 4.1.3 Performance
29 - 4.1.4 Pump casing
29 - 4.1.5 Water passages
29 - 4.1.6 Impellers
30 - 4.1.7 Shaft
30 - 4.1.8 Bearings
30 - 4.1.9 Shaft seal
30 - 4.1.10 Direction of rotation indication
31 - 4.2 END-SUCTION PUMPS
31 - 4.2.1 General design
31 - 4.2.2 Casing
31 - 4.2.3 Impeller
31 - 4.2.4 Coupling
31 - 4.3 AXIALLY SPLIT CASE PUMPS (HORIZONTAL OR VERTICAL SHAFT)
31 - 4.3.1 Casing
31 - 4.3.2 Impeller
31 - 4.3.3 Shaft
31 - 4.4 MULTISTAGE CENTRIFUGAL PUMPS
31 - 4.4.1 Performance
31 - 4.4.2 Casing
32 - 4.4.3 Impellers
32 - 4.4.4 Shaft
32 - 4.5 TURBINE TYPE CENTRIFUGAL PUMPS (VERTICAL SHAFT)
32 - 4.5.1 Discharge head assembly
32 - 4.5.2 Bowl assembly
32 - 4.5.3 Impellers
32 - 4.5.4 Column pipes
32 - 4.5.5 Shafts
33 - 4.5.6 Line-shaft coupling
33 - 4.5.7 Line-shaft bearings
33 - 4.5.8 Line-shaft enclosing tube
33 - 4.5.9 Oil lubrication system
34 - 4.5.10 Automatic air-release valve
34 - 4.6 DRIVERS FOR VERTICAL TURBINE PUMPS
34 - 4.6.1 Permissible types
34 - 4.6.2 Provision for axial thrust
34 - 4.6.3 Provision for non-reversing
34 - 4.6.4 Right-angle gear drives
35 - SECTION 5 REQUIREMENTS FOR PRESSURE MAINTENANCE PUMPS
35 - 5.1 GENERAL
35 - 5.2 GENERAL REQUIREMENTS
37 - SECTION 6 FIRE HOSE REEL PUMPSETS
37 - 6.1 GENERAL
37 - 6.2 PREASSEMBLED FIRE HOSE REEL PUMPSETS
37 - 6.3 TYPES
37 - 6.4 OPERATION
38 - 6.5 ELECTRICAL
38 - 6.5.1 Wiring
38 - 6.5.2 Supply
38 - 6.5.3 Isolating switch
38 - 6.6 VALVES
38 - 6.7 UNIONS
38 - 6.8 MAXIMUM ALLOWABLE WORKING PRESSURE
38 - 6.9 MARKING
40 - SECTION 7 RESIDENTIAL/DOMESTIC SPRINKLER PUMPSETS
40 - 7.1 GENERAL
40 - 7.2 PREASSEMBLED RESIDENTIAL/DOMESTIC SPRINKLER PUMPSETS
40 - 7.3 PUMPSET TYPE
40 - 7.4 OPERATION
40 - 7.5 ELECTRICAL
40 - 7.5.1 Wiring
41 - 7.5.2 Supply
41 - 7.5.3 Isolating switch
41 - 7.6 VALVES
41 - 7.7 UNIONS
41 - 7.8 MAXIMUM ALLOWABLE WORKING PRESSURE
41 - 7.9 MARKING
43 - SECTION 8 ELECTRIC DRIVERS AND CONTROLLERS
43 - 8.1 ELECTRIC DRIVERS
43 - 8.1.1 General
43 - 8.1.2 Types of wiring
43 - 8.1.3 Basis of rating
43 - 8.2 ELECTRIC CONTROLLERS
43 - 8.2.1 General
44 - 8.2.2 Location
44 - 8.2.3 Controller cabinets
44 - 8.2.4 Isolating switch
44 - 8.2.5 Motor starter
44 - 8.2.6 Equipment segregation
45 - 8.2.7 Control devices
45 - 8.2.8 Indicator lights
45 - 8.2.9 Aural alarms
45 - 8.2.10 Alarm power supply
45 - 8.2.11 Test facility
45 - 8.2.12 Ammeter
46 - 8.2.13 Conductor terminations
46 - 8.2.14 Battery
46 - 8.2.15 Battery chargers
46 - 8.2.16 Wiring diagrams
46 - 8.2.17 Marking
47 - 8.2.18 Access for inspection and testing
47 - 8.2.19 Predelivery testing
47 - 8.3 WIRING
47 - 8.3.1 Field wiring
48 - SECTION 9 COMPRESSION-IGNITION DRIVERS AND CONTROLLERS
48 - 9.1 GENERAL REQUIREMENTS
48 - 9.1.1 Driver type
48 - 9.1.2 Power transmission
48 - 9.2 DRIVER PERFORMANCE
48 - 9.2.1 Fuel
48 - 9.2.2 Power rating and speed
48 - 9.2.3 Service life
48 - 9.2.4 Starting capability
49 - 9.3 DRIVER SYSTEMS
49 - 9.3.1 Lubrication system
49 - 9.3.2 Cooling system
50 - 9.3.3 Fuel system
50 - 9.3.4 Air induction system
51 - 9.3.5 Exhaust system
51 - 9.3.6 Starting and stopping systems
53 - 9.3.7 Instrumentation
54 - 9.3.8 Governor
54 - 9.3.9 Guards
54 - 9.3.10 Marking
54 - 9.4 COMPRESSION-IGNITION DRIVER CONTROLLERS
54 - 9.4.1 General
54 - 9.4.2 Location
54 - 9.4.3 Controller cabinets
54 - 9.4.4 Isolating switch
55 - 9.4.5 Equipment segregation
55 - 9.4.6 Control functions
55 - 9.4.7 Indicator lights
55 - 9.4.8 Aural alarm
56 - 9.4.9 Conductor terminations
56 - 9.4.10 Mains wiring to controller
56 - 9.4.11 Controller to driver interconnecting wiring
56 - 9.4.12 Battery chargers
56 - 9.4.13 Generator/alternator isolation
56 - 9.4.14 Locked switches
56 - 9.4.15 Instructions
57 - 9.4.16 Access for inspection and testing
57 - 9.4.17 Predelivery testing
57 - 9.4.18 Wiring diagram
57 - 9.4.19 Marking
57 - 9.4.20 Test facility
57 - 9.5 ELECTRICAL CONNECTIONS ON ENGINE
57 - 9.6 SPARE PARTS
62 - SECTION 10 SHOP TESTING AND CERTIFICATION
62 - 10.1 GENERAL
62 - 10.2 HYDROSTATIC TESTS
62 - 10.2.1 Pump casing
62 - 10.2.2 Ancillary equipment
62 - 10.3 PERFORMANCE TESTS
62 - 10.3.1 General
62 - 10.3.2 Pump
63 - 10.3.3 Electric driver sets
63 - 10.3.4 Compression-ignition driver sets
63 - 10.3.5 Controller
63 - 10.3.6 Mechanical checks
64 - 10.4 CERTIFICATION
65 - SECTION 11 SITING AND INSTALLATION
65 - 11.1 GENERAL
65 - 11.2 TEMPERATURE
65 - 11.3 LOCATION
65 - 11.4 LIGHTING
65 - 11.5 VENTILATION
65 - 11.6 DRAINAGE
65 - 11.7 PLINTHS
65 - 11.8 PROTECTION OF THE OVERALL SYSTEM AGAINST DAMAGE DUE TO MOVEMENT OR PRESSURE
65 - 11.9 IDENTIFICATION OF PIPEWORK
66 - SECTION 12 COMMISSIONING TESTING
67 - APPENDIX A - REFERENCED DOCUMENTS
67 - A1 REFERENCED DOCUMENTS
69 - APPENDIX B - BORES FOR WATER SUPPLY DEDICATED TO FIREFIGHTING
69 - B1 SCOPE
69 - B2 SUPPLY FROM BORES
69 - B3 BORE SITE
69 - B4 TYPE OF PUMP
69 - B5 PUMP SUBMERGENCE
69 - B6 DESIGN
69 - B7 BOREHOLE DRILLINGS
69 - B8 CASING SIZE
70 - B9 CASING DESIGN STRESSES
70 - B10 SELECTION OF MATERIALS
70 - B11 SEALING OF CASING
70 - B12 DEVELOPING A BORE
71 - B13 PUMP INSTALLATION
71 - B14 ELECTRICAL EARTHING
71 - B15 TEST AND INSPECTION OF BORE
71 - B16 SCREENS AND SLOTTED CASING
71 - B17 WATER LEVEL INDICATION
72 - APPENDIX C - GUIDELINES FOR THE SELECTION OF DRIVERS
72 - C1 GENERAL
72 - C2 PUMP RATED POWER
72 - C3 ELECTRIC DRIVERS
72 - C4 COMPRESSION-IGNITION DRIVERS
74 - APPENDIX D - OPERATIONAL WARNING SIGNS (TYPICAL)
75 - APPENDIX E - WIRING SYSTEMS RATING
75 - E1 PROTECTION AGAINST EXPOSURE TO FIRE
75 - E2 PROTECTION AGAINST MECHANICAL DAMAGE
76 - E3 PROTECTION AGAINST HOSING WITH WATER
77 - APPENDIX F - THE PUMPHOUSE
77 - F1 SCOPE
77 - F2 LOCATION
77 - F3 LIGHTING
77 - F4 VENTILATION
77 - F5 DRAINAGE
77 - F6 PIPEWORK
77 - F6.1 Penetration of walls
78 - APPENDIX G - GUIDE TO EXHAUST SYSTEM SIZING
78 - G1 METHOD OF SELECTION
78 - G2 USING THE EXHAUST SYSTEM SIZING CHART (FIGURE G1)
80 - APPENDIX H - TYPICAL PERFORMANCE TEST DATA SHEETS
82 - APPENDIX I - COMMISSIONING TESTS
82 - I1 SCOPE
82 - I2 GENERAL
82 - I3 ELECTRIC MOTOR PUMPSETS
82 - I3.1 Purpose
82 - I3.2 Preparation
82 - I3.3 Procedure
83 - I3.4 Reporting of results
83 - I4 COMPRESSION-IGNITION ENGINE PUMPSETS
83 - I4.1 Purpose
83 - I4.2 Preparation
84 - I4.3 Procedure
85 - I4.4 Reporting of results
85 - I5 AUTOMATIC PRESSURE MAINTENANCE PUMPSETS
85 - I5.1 Purpose
85 - I5.2 Procedure
85 - I5.3 Reporting of results
86 - I6 LOCATION OF PRESSURE GAUGES

Specifies specific requirements for pumpset systems to be used with fixed fire protection installation such as fire sprinkler, fire hydrant, fire hose reel and fire protection water spray systems.

Committee
FP-008
DocumentType
Standard
ISBN
0 7337 4642 X
Pages
80
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for pumpset systems, generally represented by the equipment contained in Figures 3.4 and 3.5, for use with fixed fire protection installations such as sprinkler, hydrant, water spray, and hose reel systems. It covers water supplies and specific requirements for pumps, drivers, fire pump controllers, and auxiliary equipment. Requirements for installation and acceptance testing for electrical and compression-ignition drivers are also included.NOTE:Some special fire pump installations, e.g., at petrochemical and petroleum plants and small rural installations may require variations from the requirements of this Standard.

First published as AS 2941-1987.
Second edition 1995.
Third edition 2002.

AS 1403-2004 Design of rotating steel shafts (Reconfirmed 2016)
AS 1359.30-1997 Rotating electrical machines - General requirements - Preferred outputs and frame sizes
AS 4594.6-1999 Internal combustion engines - Performance Engines for land, rail-traction and marine use - Overspeed protection
AS 2417-2001 Rotodynamic pumps - Hydraulic performance acceptance tests - Grades 1 and 2
AS/NZS 1221:1997 Fire hose reels (Reconfirmed 2020)
AS 4029.2-1992 Stationary batteries - Lead-acid - Valve-regulated sealed type
AS 1221-1991 Fire hose reels
AS 1210-1997 Pressure vessels
AS/NZS 3947.3:2001 Low-voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fuse-combination units
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1359.101-1997 Rotating electrical machines - General requirements Rating and performance
AS 3731.1-1995 Stationary batteries - Nickel-cadmium Vented type
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS 3947.4.2-1997 Low-voltage switchgear and controlgear Contractors and motor starters - A.C. semiconductor motor controllers and starters
AS 4024.4-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Pressure-sensitive devices (Reconfirmed 2016)
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS 1396-2000 Steel water bore casing
AS 4594.4-1999 Internal combustion engines - Performance Engines for land, rail-traction and marine use - Speed governing
AS 3731.2-1995 Stationary batteries - Nickel-cadmium Valve-regulated type
AS 1722.1-1975 Pipe threads of Whitworth form Sealing pipe threads (metric units)
AS 2293.1-2005 Emergency escape lighting and exit signs for buildings System design, installation and operation
AS 1692-1989 Tanks for flammable and combustible liquids
AS 1359.41-1986 Rotating electrical machines - General requirements General characteristics
AS 4024.5-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Pressure-sensitive devices
AS 2118.4-1995 Automatic fire sprinkler systems - Residential
AS 1345-1995 Identification of the contents of pipes, conduits and ducts (Reconfirmed 2018)
AS 1349-1986 Bourdon tube pressure and vacuum gauges (Reconfirmed 2018)
AS 2430.1-1987 Classification of hazardous areas - Explosive gas atmospheres
AS 2118.5-1995 Automatic fire sprinkler systems - Domestic
AS 1755-2000 Conveyors - Safety requirements
AS 1359.10-1989 Rotating electrical machines - General requirements - Designations and dimensions
AS 4024.2-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Optoelectronic devices
AS 3570-1998 Automotive diesel fuel
AS 4594.1-1999 Internal combustion engines - Performance Standard reference conditions, declarations of power, fuel and lubricating oil consumptions, and test methods
AS 2129-2000 Flanges for pipes, valves and fittings (Reconfirmed 2016)
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS 4594.7-1999 Internal combustion engines - Performance Engines for land, rail-traction and marine use - Codes for engine power
AS 4118.1.6-1995 Fire sprinkler systems Components - Stop valves and non-return valves (Reconfirmed 2013)
AS 4594.3-1999 Internal combustion engines - Performance Engines for land, rail-traction and marine use - Test measurements
AS 4594.5-1999 Internal combustion engines - Performance Engine for land, rail-traction and marine use - Torsional vibrations
AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
AS 3709-1989 Vibration and shock - Balance quality of rotating rigid bodies
AS 1851.14-1996 Maintenance of fire protection equipment - Pumpset systems
AS/NZS 3013:1995 Electrical installations - Classification of the fire and mechanical performance of wiring systems
AS/NZS 3947.4.2:2000 Low-voltage switchgear and controlgear Contactors and motor-starters - A.C. semiconductor motor controllers and starters
AS 2293.1-1987 Emergency evacuation lighting in buildings Design and installation
AS 4594.8-1999 Internal combustion engines - Performance Engines for road vehicle use - Test code, net power
AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
AS 4029.3-1993 Stationary batteries - Lead-acid Pure lead positive pasted plate type
AS 1692-2006 Steel tanks for flammable and combustible liquids (Reconfirmed 2016)
AS 4024.1-1996 Safeguarding of machinery General principles
AS 1403-1985 Design of rotating steel shafts
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS/NZS 3947.4.1:2001 Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters
AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
AS 4024.3-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Optoelectronic devices
AS 2118.1-1999 Automatic fire sprinkler systems General requirements
AS 4594.0-1999 Internal combustion engines - Performance Application
AS 4594.9-1999 Internal combustion engines - Performance Engines for road vehicle use - Test code, gross power

AS 2118.5-1995 Automatic fire sprinkler systems - Domestic
AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS 3846-2005 The handling and transport of dangerous cargoes in port areas
AS 1894-1997 The storage and handling of non-flammable cryogenic and refrigerated liquids (Reconfirmed 2021)
AS 1940-2004 The storage and handling of flammable and combustible liquids
AS 2441-2005 Installation of fire hose reels (Reconfirmed 2018)
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2118.6-1995 Automatic fire sprinkler systems - Combined sprinkler and hydrant
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2118.10-1995 Automatic fire sprinkler systems Approval documentation (Reconfirmed 2013)
AS 2118.2-1995 Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers)
AS 2118.4-1995 Automatic fire sprinkler systems - Residential
AS/NZS 2927:2001 The storage and handling of liquefied chlorine gas
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS/NZS 3500.1:2003 Plumbing and drainage Water services
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
AS/NZS 4081:2001 The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021)
AS 2419.1-2005 Fire hydrant installations System design, installation and commissioning

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.