AS 3011.1-1992
AvailableSuperseded
An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.
Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
23-12-1991
Specifies requirements for the installation of vented secondary batteries permanently installed in buildings.
Committee |
EL-005
|
DocumentType |
Standard
|
ISBN |
0 7262 7305 8
|
Pages |
6
|
PublisherName |
Standards Australia
|
Status |
AvailableSuperseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for the installation of vented secondary batteries with a nominal voltage exceeding 24 V and a capacity exceeding 10 A.h at the 1 h rate of discharge, permanently installed in or on buildings, structures or premises to ensure safety from fire and electric shock.AS 2676.1 provides guidance on the installation and maintenance of vented secondary batteries.This Standard covers vented cells only. The installation and maintenance of sealed cells are covered by AS 3011.2 and AS 2676.2.NOTE: Requirements specifically applicable to the design and installation of extra-low voltage (d.c.) power supplies that are used by telecommunications carriers in the provision of public telecommunications networks are given in AS 3015(Int)-1991, Electrical installations - Extra-low voltage (d.c.) power supplies in public telecommunications networks.
First published as part of AS 2676-1983.
AS 2676-1983 revised and redesignated in part as AS 3011-1987.
AS 3011-1987 revised and redesignated AS 3011.1-1990.
Second edition 1992.
AS 1680.1-1990 | Interior lighting General principles and recommendations |
AS/NZS 1680.1:2006 | Interior and workplace lighting General principles and recommendations |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS 2676.2-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells |
AS 1775-1984 | Low voltage switchgear and controlgear - Air-break switches, isolators and fuse-combination units (up to and including 1000 V a.c. and 1200 V d.c.) |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 1136.1-1988 | Low voltage switchgear and controlgear assemblies General requirements |
AS 3015-1993 | Electrical installations - Extra-low voltage d.c. power supplies within public telecommunications networks |
AS 3516.2-1998 | Siting of radiocommunications facilities - Guidelines for fixed, mobile and broadcasting services operating at frequencies above 30 MHz |
AS/NZS 3015:2004 | Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 3003:2018 | Electrical installations - Patient areas |
AS/NZS 4777.1:2016 | Grid connection of energy systems via inverters Installation requirements |
AS 4029.1-1994 | Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1) |
AS 2676.2-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells |
AS 3084-1993 | Telecommunications installations - Telecommunications pathways and spaces for commercial buildings |
AS/NZS 3003:1999 | Electrical installations - Patient treatment areas of hospitals and medical and dental practices |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 3003:2003 | Electrical installations - Patient treatment areas of hospitals and medical, dental practices and dialyzing locations |
AS 2201.2-1992 | Intruder alarm systems - Central stations |
AS/NZS 3003:2011 | Electrical installations - Patient areas |
AS/NZS 3084:2003 | |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 2201.2-2001 | Intruder alarm systems - Monitoring centres |
AS/NZS 4509.1:2009 | Stand-alone power systems Safety and installation (Reconfirmed 2017) |
AS/NZS 3010:2005 | Electrical installations - Generating sets |
AS/NZS 2381.1:2005 | Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements |
AS 3015(INT)-1991 | Electrical installations - Extra-low voltage (d.c.) power supplies in public telecommunications networks |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS/NZS 3084:2017 | Telecommunications installations - Telecommunications pathways and spaces for commercial buildings |
AS/NZS 2201.1:2007 | Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance |
AS 2201.2-2004 | Intruder alarm systems Monitoring centres |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS/NZS 2293.1:1995 | Emergency evacuation lighting for buildings System design, installation and operation |
AS 1670.3-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning - Fire alarm monitoring |
AS 1851-2005 | Maintenance of Fire Protection Systems and Equipment |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
AS 4086.2-1997 | Secondary batteries for use with stand-alone power systems Installation and maintenance |
AS/NZS 2293.1:1998 | Emergency evacuation lighting for buildings System design, installation and operation |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.