• Shopping Cart
    There are no items in your cart

AS 3565.2-2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Meters for water supply - Combination meters

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS 3565.1-2010

Language(s)

English

Published date

01-01-2004

€65.33
Excluding VAT

1 - AS 3565.2-2004 METERS FOR WATER SUPPLY - COMBINATION METERS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 INTERPRETATION
6 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Changeover flow rate
7 - 1.4.2 Flow rate (Q)
7 - 1.4.3 Flow rate range
7 - 1.4.4 Maximum permissible error of measurement
7 - 1.4.5 Minimum flow rate (Q1)
7 - 1.4.6 Overload flow rate (Q4)
7 - 1.4.7 Permanent flow rate (Q3)
7 - 1.4.8 Pressure loss (delta p)
7 - 1.5 DESIGNATION OF SIZE
8 - 1.6 DESIGNATION OF CAPACITY
8 - 1.7 PREFERRED FLOW RATES
8 - 1.8 DIMENSIONS
8 - 1.9 MARKINGS
8 - 1.9.1 Identification marks
8 - 1.9.2 Verification marks
9 - SECTION 2 MATERIALS AND COMPONENTS
9 - 2.1 MATERIALS
9 - 2.2 END CONNECTIONS
9 - 2.3 REGISTERS
9 - 2.3.1 General
9 - 2.3.2 Register design
9 - 2.3.3 Number of decades
9 - 2.3.4 Indicators
9 - 2.3.5 Verification scale
10 - 2.4 CALIBRATION ADJUSTMENT DEVICE
10 - 2.5 PROTECTIVE DEVICES
11 - SECTION 3 PERFORMANCE REQUIREMENTS
11 - 3.1 GENERAL
11 - 3.2 ULTRAVIOLET LIGHT EXPOSURE
11 - 3.3 WATERTIGHTNESS
11 - 3.3.1 General
11 - 3.3.2 Type test
11 - 3.3.3 Batch test
11 - 3.4 CHANGEOVER FLOW RATE TEST
11 - 3.5 REVERSE FLOW
11 - 3.6 PRESSURE LOSS
11 - 3.7 MAXIMUM PERMISSIBLE ERROR OF MEASUREMENT
11 - 3.7.1 General
11 - 3.7.2 MPE lower flow range
12 - 3.7.3 MPE upper flow range
12 - 3.8 ENDURANCE
13 - SECTION 4 PERFORMANCE TESTS
13 - 4.1 TESTS AND SEQUENCE
13 - 4.1.1 General
13 - 4.1.2 Pattern approval
13 - 4.1.3 Type tests
13 - 4.2 APPARATUS
14 - APPENDIX A - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS STANDARD
14 - A1 SCOPE
14 - A2 RELEVANCE
14 - A3 PRODUCT CERTIFICATION
14 - A3.1 Definitions
15 - A3.2 Batch release test (BRT)
15 - A3.3 Type testing (TT)
15 - A4 TESTING
15 - A4.1 General
15 - A4.2 Type testing sampling
15 - A4.3 Retesting
15 - A4.4 Pattern approval
15 - A4.5 Acceptability of tests
17 - APPENDIX B - PURCHASING GUIDELINES
17 - B1 GENERAL
17 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
17 - B3 CERTIFICATE OF COMPLIANCE
18 - APPENDIX C - METROLOGICAL REQUIREMENTS
18 - C1 SCOPE
18 - C2 METROLOGICAL DATA
18 - C3 TECHNICAL DATA
20 - APPENDIX D - CHANGEOVER FLOW RATE TEST
20 - D1 SCOPE
20 - D2 PRINCIPLE
20 - D3 APPARATUS
20 - D4 PROCEDURE
21 - D5 REPORT
22 - APPENDIX E - PRESSURE LOSS TEST
22 - E1 SCOPE
22 - E2 PRINCIPLE
22 - E3 APPARATUS
22 - E4 PROCEDURE
23 - E5 CALCULATIONS
23 - E6 REPORT
24 - APPENDIX F - ENDURANCE TEST
24 - F1 SCOPE
24 - F2 PRINCIPLE
24 - F3 APPARATUS
24 - F4 PROCEDURE
25 - F5 REPORT

Specifies the requirements for combination meters, with nominal flow rates not exceeding 150 kL/h and consisting of one small meter and one large meter in parallel, with a changeover device. These combination meters are intended for installation in water services, to measure within the specified accuracy limits, the volume of cold drinking water at working temperature range of 0.3 degrees Celsius to 30 degrees Celsius and pressure not exceeding 1400 kPa, respectively.

Committee
WS-024
DocumentType
Standard
ISBN
0 7337 5494 5
Pages
20
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for combination meters with nominal flow rates not exceeding 150 kL/h and consisting of one small meter and one large meter in parallel, with a changeover device.These combination meters are intended for installation in water services, to measure, within the specified accuracy limits, the volume of cold drinking water at working temperature range of 0.3°C to 30°C and pressure not exceeding 1400 kPa, respectively. This Standard is applicable to combination meters that are capable of operating at intermittent temperatures of at least 50°C, which may be fitted with electronic output devices (EOD), are self-contained and capable of continuously determining, within the accuracy limits of the meter the volume of cold drinking water that has flowed through them, and are continuously indicating the volume on a cumulative basis. Such volume being equal to either— (a) the sum of the volumes shown on the registers of the small and large meters; or (b) the volume shown on the single register for both the small and large meters. Means for demonstrating compliance with this Standard are given in Appendix A NOTE: Purchasing guidelines are given in Appendix B.

First published as AS 3565.2-1996.
Second edition 2004.

AS 4087-1996 Metallic flanges for waterworks purposes
HB 18.28-1991 Guidelines for third-party certification and accreditation - Guide 28: General rules for a model third-party certification system for products
AS 2345-1992 Dezincification resistance of copper alloys
AS 2345-2006 Dezincification resistance of copper alloys
HB 18.28-2005 Conformity assessment - Guidance on a third-party certification system for products
AS 4087-2004 Metallic flanges for waterworks purposes
AS 3565.1-2004 Meters for water supply Cold water meters
AS/NZS 4020:2005 Testing of products for use in contact with drinking water

AS 5200.000-2006 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products (Reconfirmed 2018)
MP 52-2005 Manual of authorization procedures for plumbing and drainage products
AS 5200.000-2005 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.