• Shopping Cart
    There are no items in your cart

AS 3771-1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Road lighting luminaires with integral control gear

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

26-06-2021

Superseded by

AS/NZS 1158.6:2004

Language(s)

English

Published date

01-01-1998

€65.33
Excluding VAT

1 - AS 3771-1998 ROAD LIGHTING LUMINAIRES WITH INTEGRAL CONTROL GEAR
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Aeroscreen luminaire
7 - 1.4.2 Category B luminaire
8 - 1.4.3 Category V luminaire
8 - 1.4.4 Luminaire
8 - 1.4.5 Post-top luminaire
8 - 1.4.6 Rated voltage
8 - 1.4.7 Side-entry luminaire
8 - 1.4.8 Type P (photoelectrically controlled) luminaire
8 - 1.4.9 Type R (remotely switched) luminaire
8 - 1.5 ENVIRONMENTAL CONDITIONS
8 - 1.6 MARKING
8 - 1.6.1 Identification of manufacture
8 - 1.6.2 Coded information on luminaire
9 - 1.6.3 Additional marking for Category B luminaires with high pressure sodium lamps
9 - 1.7 EQUIPMENT TO BE PROVIDED
10 - SECTION 2 MECHANICAL AND PHYSICAL REQUIREMENTS
10 - 2.1 SCOPE OF SECTION
10 - 2.2 GENERAL DESIGN AND ARRANGEMENT
10 - 2.2.1 Form and construction
10 - 2.2.2 Required protection
10 - 2.3 LUMINAIRE BODY
10 - 2.3.1 Material
10 - 2.3.2 Component fixing devices
10 - 2.3.3 Seals and gaskets
11 - 2.4 VISORS
11 - 2.4.1 Function
11 - 2.4.2 Attachment to luminaire body
11 - 2.4.3 Materials and construction
11 - 2.5 OPTICAL SYSTEM
12 - 2.6 FIXING SPIGOT ENTRY
12 - 2.6.1 Form and dimensions
12 - 2.6.2 Means of attachment
12 - 2.6.3 Adjustment of upcast (for Category V luminaires)
13 - 2.7 MAXIMUM MASS (FOR SIDE-ENTRY LUMINAIRES)
14 - SECTION 3 ELECTRICAL WIRING AND COMPONENTS
14 - 3.1 SCOPE OF SECTION
14 - 3.2 ELECTRICAL SUPPLY
14 - 3.3 ESSENTIAL SAFETY REQUIREMENTS
14 - 3.4 CABLE ENTRY
14 - 3.5 TERMINAL BLOCK
14 - 3.6 BALLASTS
14 - 3.7 LAMPHOLDERS
15 - 3.8 ARRANGEMENT OF CONTROL GEAR
15 - 3.8.1 Mounting of equipment
15 - 3.8.2 Hinged trays
15 - 3.9 SOCKET FOR PHOTOELECTRIC CELL SWITCH (FOR TYPE P LUMINAIRES)
15 - 3.9.1 Base type
15 - 3.9.2 Connection arrangement (for Category B luminaires)
15 - 3.9.3 Colour coding of connecting wiring
15 - 3.10 INTERNAL WIRING
17 - SECTION 4 ADDITIONAL REQUIREMENTS FOR PARTICULAR LUMINAIRES
17 - 4.1 SCOPE OF SECTION
17 - 4.2 CATEGORY V LUMINAIRES
17 - 4.2.1 Luminaires for high pressure mercury vapour lamps
17 - 4.2.2 Luminaires for high pressure sodium vapour lamps
18 - 4.3 CATEGORY B LUMINAIRES
18 - 4.3.1 Luminaires for high pressure mercury vapour lamps
18 - 4.3.2 Luminaires for high pressure sodium vapour lamps
18 - 4.3.3 Luminaires for low pressure sodium vapour lamps.
18 - 4.4 OPTIONAL COMPONENTS (CATEGORY V AND CATEGORY B LUMINAIRES)
18 - 4.4.1 Power factor correction capacitors
19 - 4.4.2 Blocking inductor
19 - 4.4.3 Overcurrent protection
19 - 4.4.4 Interference suppression capacitors
21 - SECTION 5 PERFORMANCE AND TESTING
21 - 5.1 SCOPE OF SECTION
21 - 5.2 TESTING OF TYPE P LUMINAIRES
21 - 5.3 BALLAST LOSSES
21 - 5.4 LAMP OPERATION
21 - 5.5 PHOTOMETRIC PERFORMANCE
21 - 5.5.1 Category V luminaires
22 - 5.5.2 Category B luminaires
22 - 5.6 WIND FORCE TEST
22 - 5.6.1 Test conditions and procedure
22 - 5.6.2 Test criteria
22 - 5.7 DUST TEST
22 - 5.7.1 Application of test
22 - 5.7.2 Test conditions and procedure
23 - 5.7.3 Test criteria
24 - 5.8 IMPULSE VOLTAGE TEST
24 - 5.8.1 Test conditions and procedure
24 - 5.8.2 Test criteria
24 - 5.9 GENERAL CONDITIONS FOR ENDURANCE AND THERMAL TESTS.
24 - 5.9.1 Selection of lamps
24 - 5.9.2 Mounting of luminaire
24 - 5.9.3 Connection to supply
24 - 5.9.4 Temperature measurements
24 - 5.9.5 Application of temperature limits
24 - 5.10 ENDURANCE TEST
24 - 5.10.1 General
24 - 5.10.2 Test conditions and procedure
25 - 5.10.3 Test criteria
25 - 5.11 THERMAL TEST (NORMAL OPERATION)
25 - 5.11.1 Test conditions and procedure
26 - 5.11.2 Test criteria
27 - 5.12 TEMPERATURE TEST (ABNORMAL OPERATION)
27 - 5.12.1 Application of test
27 - 5.12.2 Test conditions and procedure
28 - 5.12.3 Test criteria
30 - SECTION 6 SUPPORTING DOCUMENTATION
30 - 6.1 SCOPE OF SECTION
30 - 6.2 GENERAL INFORMATION
30 - 6.3 PHOTOMETRIC INFORMATION
30 - 6.3.1 General
30 - 6.3.2 Luminous intensity data
30 - 6.3.3 Isolux diagrams (for Category V luminaires)
30 - 6.3.4 Isolux diagrams (for Category B luminaires)
31 - 6.4 EVIDENCE OF COMPLIANCE
32 - APPENDIX A - INFORMATION TO BE SUPPLIED WITH ENQUIRY OR ORDER
33 - APPENDIX B - LIST OF REFERENCED DOCUMENTS
35 - APPENDIX C - SELECTION OF TEST LAMPS
36 - APPENDIX D - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS STANDARD
36 - D1 SCOPE
36 - D2 STATISTICAL SAMPLING
36 - D3 PRODUCT CERTIFICATION
36 - D4 SUPPLIER'S QUALITY SYSTEM
37 - D5 OTHER MEANS OF ASSESSMENT

Specifies requirements for the design, construction, performance and testing of road lighting luminaires with integral control gear, to ensure their suitability for the operating and environmental conditions to which they will be subjected in service. Applies to luminaires with discharge lamps of various types and ratings, which are designed to provide road lighting of Category V in accordance with AS/NZS 1158.1.1 or Category B in accordance with AS 1158.1.

Committee
LG-002
DocumentType
Standard
ISBN
0 7337 1548 6
Pages
31
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard applies to luminaires with integral control gear which are designed to provide road lighting of Category V in accordance with AS/NZS 1158.1.1 or Category B in accordance with AS 1158.1. It specifies requirements for the design, construction, performance and testing of the luminaires and for the supporting documentation which should be provided.NOTE: Appendix A lists the information which should be supplied by the purchaser with an enquiry or order for road lighting luminaires complying with this Standard.

First published as AS 3771-1990.
Second edition 1998.

AS/NZS 4051:1998 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
AS/NZS 1158.0:2005 Lighting for roads and public spaces Introduction
AS 1158.1-1986 The lighting of urban roads and other public thoroughfares Performance and installation design requirements
AS 2644-1990 Capacitors for use in discharge lamp circuits
AS/NZS 1158.0:1997 Road lighting Introduction
HB 18.28-2005 Conformity assessment - Guidance on a third-party certification system for products
AS 2768-1985 Electrical insulating materials - Evaluation and classification based on thermal endurance
AS 1874-1988 Aluminium and aluminium alloys - Ingots and castings
AS/NZS 1158.1.1:1997 Road Lighting Vehicular traffic (Category V) lighting - Performance and installation design requirements
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
AS/NZS ISO 9001:1994 Quality systems - Model for quality assurance in design, development, production, installation and servicing
AS/NZS 3191:2003 Electric flexible cords
AS/NZS 3117:2007 Approval and test specification - Bayonet lampholders
AS 1874-2000 Aluminium and aluminium alloys - Ingots and castings (Reconfirmed 2018)
AS 1399-1990 Guide to AS 1199 - Sampling procedures and tables for inspection by attributes
AS 1789-1984 Electroplated coatings - Zinc on iron or steel
AS/NZS 1158.1.1:2005 Lighting for roads and public spaces Vehicular traffic (Category V) lighting - Performance and design requirements
AS 2643-1991 Fluorescent lamp ballasts of reactive type - Performance requirements
BS EN 60598-1:2015 Luminaires General requirements and tests
AS 1789-2003 Electroplated zinc (electrogalvanized) coatings on ferrous articles (batch process) (Reconfirmed 2017)
AS/NZS ISO 9004.1:1994 Quality management and quality system elements Guidelines
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1798-1992 Lighting poles and bracket arms - Preferred dimensions
AS 3140-1994 Approval and test specification - Edison-type screw lampholders
AS 1199-1988 Sampling procedures and tables for inspection by attributes
AS 3145-1979 Approval and test specification for radio interference suppression devices
I.S. EN 60598-1:2015 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
UNE-EN 60598-1:2015 Luminaires - Part 1: General requirements and tests
12/30266672 DC : 0 BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
AS/NZS 3100:1997 Approval and test specification - General requirements for electrical equipment
AS 3191-1981 Approval and test specification for electric flexible cords (incorporating Corrigenda)
AS 3117-1994 Approval and test specification - Bayonet lampholders
AS/NZS ISO 9001:2000 Quality management systems - Requirements
AS 3137-1992 Approval and test specification - Luminaires (lighting fittings)
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS 1650-1989 Hot-dipped galvanized coatings on ferrous articles
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS/NZS ISO 9000.1:1994 Quality management and quality assurance standards Guidelines for selection and use
EN 60598-1:2015/A1:2018 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
CSA E60598.1 : 2016 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS

AS/NZS 60598.1:2017 Luminaires General requirements and tests (IEC 60598-1, Ed. 8.0 (2014) MOD)
AS/NZS 60598.1:2013 Luminaires General requirements and tests (IEC 60598-1, Ed. 7.0 (2008) MOD)
AS/NZS 1158.1.3:1997 Road lighting Vehicular traffic (Category V) lighting - Guide to design, installation, operation and maintenance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.