AS/NZS 2430.3.1:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Classification of hazardous areas Examples of area classification - General
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-05-2024
20-05-2004
This Standard provides examples of area classification and is based on the internationally accepted concept which recognizes the different degrees of probability with which explosive (flammable) concentrations of flammable gas or vapour may arise in installations in terms of both the frequency of occurrence and the probable duration of existence on each occasion.
Committee |
MS-011
|
DocumentType |
Standard
|
ISBN |
0 7337 5968 8
|
Pages |
8
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard provides examples of area classification and is based on the internationally accepted concept which recognizes the different degrees of probability with which explosive (flammable) concentrations of flammable gas or vapour may arise in installations in terms of both the frequency of occurrence and the probable duration of existence on each occasion. The recommended classifications of this Standard are based on the assumption that plant and equipment are adequately maintained. The Standard is part of a series which recommends the classifications of several commonly occurring situations. NOTE: Appendix A provides methods of classification. This Standard details general matters which must be taken into account when using any other of the AS/NZS 2430.3 series of Standards for the purpose of conducting an area classification. This Standard covers risks due to both fire and explosion. The examples in this Standard may not apply to specific occupancies where— (a) the quantity of release is either very large or very small, in such cases dispersion calculations may be required; (b) the design of a particular plant does not comply with the appropriate Australian or New Zealand Standards; or (c) ventilation, use of inert gases, vapour barriers or other methods, are used to reduce the extent or degree of risk of a particular hazardous area. In all cases classification may be made using the fundamental principles detailed in AS/NZS 60079.10. In general, classifications in accordance with the following codes are acceptable, subject to any additional provisions or modifications as required by the authority: (i) UK IP (Institute of Petroleum), Model Code of Safe Practice for the Petroleum Industry, Part 15: Area Classification Code for Installations Handling Flammable Fluids. (ii) API (American Petroleum Institute) RP 505, Recommended Practice for ‘Classification of Locations for Electrical Installations at Petroleum Facilities classified as Class I, Zone , Zone 1 and Zone 2’. (iii) BS 5908, Code of practice for fire precautions in the chemical and allied industries. Attention is drawn to the fact that an area classified non-hazardous, in accordance with this Standard, may not necessarily be safe in all respects, e.g. toxic and chemical hazards. Unless otherwise specified, the classifications given throughout this Standard are based on the ventilation criteria given in Appendix B.
First published in Australia as part of AS 1076.2-1977.
AS 2430.1 first published 1981.
AS 1076.2-1977 and AS 2430.1-1981 revised, amalgamated and redesignated AS 2430.1-1982.
AS 2430.1-1982 revised and redesignated in part as AS 2430.3-1987.
Second edition 1991.
First published in New Zealand as part of NZS 6101P:1972.
Revised and redesignated in part as NZS 6101.3:1991.
AS 2430.3-1991 and NZS 6101.3:1991 revised, amalgamated and redesignated in part as AS/NZS 2430.3.1:1997.
Second edition 2004.
AS/NZS 2430.3.5:1997 | Classification of hazardous areas - Examples of area classification - Refineries and major processing plants |
AS/NZS 60079.10:2004 | Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD) |
AS 2030 SUPP 1-1986 | Foreign gas cylinder specifications |
AS 2030.2-1996 | The verification, filling, inspection, testing and maintenance of cylinders for the storage and transport of compressed gases Cylinders for dissolved acetylene |
AS 2030.1-1999 | The verification, filling, inspection, testing and maintenance of cylinders for storage and transport of compressed gases Cylinders for compressed gases other than acetylene |
AS 2030.4-1985 | The verification, filling, inspection, testing and maintenance of cylinders for storage and transport of compressed gases Welded cylinders - Insulated |
AS 1482-1985 | Electrical equipment for explosive atmospheres - Protection by ventilation - Type of protection v (Reconfirmed 2013) |
AS 1940-1993 | The storage and handling of flammable and combustible liquids |
AS 4976-2008 | The removal and disposal of underground petroleum storage tanks |
AS/NZS 3833:2007 | The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers |
AS/NZS 1596:2002 | The storage and handling of LP Gas |
AS/NZS 2311:2009 | Guide to the painting of buildings |
AS/NZS 2430.3.9:2004 | Classification of hazardous areas Examples of area classification - Miscellaneous |
HB 29-2007 | Communications cabling manual - Module 2: Communications cabling handbook |
AS 5601-2004 | Gas installations |
AS 4326-2008 | The storage and handling of oxidizing agents (Reconfirmed 2024) |
AS/NZS 2243.10:2004 | Safety in laboratories Storage of chemicals |
AS/NZS 1768:2007 | Lightning protection |
AS/NZS 2430.3.4:2004 | Classification of hazardous areas Examples of area classification - Flammable gases |
AS 3961-2005 | The storage and handling of liquefied natural gas |
AS 2400.5-2005 | Packaging Temporary corrosion protection (Reconfirmed 2016) |
AS/NZS 60079.10:2004 | Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD) |
AS/NZS 2430.3.2:2004 | Classification of hazardous areas - Examples of area classification - Vehicle workshops, vehicle parking, fuel dispensing stations and aircraft hangars |
AS/NZS 4114.2:2003 | Spray painting booths, designated spray painting areas and paint mixing rooms - Installation and maintenance |
AS/NZS 2430.3.7:2004 | Classification of hazardous areas Examples of area classification - Landfill gas, sewage treatment and sewage pumping plants |
AS/NZS 4645.1:2008 | Gas distribution networks Network management |
AS 2714-2008 | The storage and handling of organic peroxides (Reconfirmed 2021) |
AS/NZS 2430.3.5:2004 | Classification of hazardous areas Examples of area classification - Refineries and major processing plants |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 3780-2008 | The storage and handling of corrosive substances |
AS/NZS 60079.30.2:2007 | Explosive atmospheres Electrical resistance trace heating - Application guide for design, installation and maintenance (IEC 60079-30-2, Ed. 1.0 (2007) MOD) |
AS 2885.1-2007 | Pipelines - Gas and liquid petroleum Design and construction |
AS/NZS 4240.1:2009 | Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021) |
AS/NZS 2381.1:2005 | Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements |
AS/NZS 2430.3.8:2004 | Classification of hazardous areas Examples of area classification - Surface coatings and adhesives |
AS/NZS 2967:2014 | Optical fibre communication cabling systems safety |
AS/NZS 3788:2006 | Pressure equipment - In-service inspection (Reconfirmed 2017) |
AS 5034-2005 | Installation and use of inert gases for beverage dispensing |
AS/NZS 2430.3.6:2004 | Classification of hazardous areas Examples of area classification - Laboratories, including fume cupboards and flammable medical agents |
HB 13-2007 | Electrical equipment for hazardous areas |
AS 2832.2-2003 | Cathodic protection of metals Compact buried structures |
AS/NZS 2430.3.3:2004 | Classification of hazardous areas Examples of area classification - Flammable liquids |
AS/NZS 2381.2:2006 | Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d |
AS 2601-2001 | The demolition of structures |
AS/NZS 2243.2:2006 | Safety in laboratories Chemical aspects |
AS 2885.1-2012 | Pipelines - Gas and liquid petroleum Design and construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.