• Shopping Cart
    There are no items in your cart

AS/NZS 4507:2006

Current

Current

The latest, up-to-date edition.

Cables - Classification of characteristics when exposed to fire

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

25-01-2006

€32.89
Excluding VAT

Specifies the performance requirements of cables when exposed to fire with respect to specific characteristics and allocates a classification.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 7083 5
Pages
6
ProductNote
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies the performance requirements of cables when exposed to fire with respect to specific characteristics and allocates a classification. The Standard specifies the criteria for tests that may be in addition to those requirements specified in relevant cable Standards.This Standard does not address issues with respect to cables initiating or being the cause of fire.Wiring system circuit integrity (WS) is covered by AS/NZS3013 and is an additional and separate cable requirement.This Standard classifies the following characteristics:(a) Reduced flame propagation (RFP).(b) Reduced hazardous effects (RHE).(c) Cable circuit integrity (CI).NOTE:1 For purchasing guidelines, see Appendix A.2 Although this Standard specifies cable characteristics under defined fire conditions, it cannot be assumed that cables would behave in the same manner in a real fire. For example, the propagation of the flame along a cable installation is influenced by a number of factors independent of the cable itself, such as—(a) the volume of combustible material exposed to the fire and to any flame which may be produced by the combustion of the cables;(b) the geometrical configuration of the cables and their relationship to any enclosure;(c) the rate of temperature rise and the peak fire temperature which influence the ignition of gases emitted from the cables;(d) the volume of air passing through the cable installation; (e) installation conditions (on ladders or trays, in conduit);(f) vertical or horizontal installation; and(g) fire quenching techniques at the installation (water sprinkler, gas suppression).

Originated as AS/NZS 4507:1998.
Second edition 2006.

AS/NZS 1660.5.5:2005 Test methods for electric cables, cords and conductors Fire tests - Circuit integrity
AS/NZS 1660.5.1:2005 Test methods for electric cables, cords and conductors Fire tests - Test for vertical flame spread of vertically-mounted bunched wires or cables
AS/NZS 1660.5.2:1998 Test methods for electric cables, cords and conductors Fire tests - Smoke density
AS/NZS 1660.5.4:1998 Test methods for electric cables, cords and conductors - Fire tests - Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS/NZS 1660.5.6:2005 Test methods for electric cables, cords and conductors Fire tests - Test for vertical flame propagation for a single insulated wire or cable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.