Electromagnetic compatibility (EMC) Testing and measurement techniques - Electrostatic discharge immunity test

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-01-2024

Language(s)

English

Published date

01-11-2002

€92.72
Excluding VAT

1 - AS/NZS 61000.4.2:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - TESTING AND MEASUREMENT TECHNIQUES-ELECTROSTATIC DISCHARGE...
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - 1 Scope
7 - 2 Normative references
8 - 3 General
8 - 4 Definitions
8 - 4.1 degradation (of performance)
8 - 4.2 electromagnetic compatibility (EMC)
8 - 4.3 antistatic material
8 - 4.4 energy storage capacitor
8 - 4.5 ESD
8 - 4.6 EUT
9 - 4.7 ground reference plane (GRP)
9 - 4.8 coupling plane
9 - 4.9 holding time
9 - 4.10 electrostatic discharge; ESD
9 - 4.11 immunity (to a disturbance)
9 - 4.12 contact discharge method
9 - 4.13 air discharge method
9 - 4.14 direct application
9 - 4.15 indirect application
9 - 5 Test levels
10 - 6 Test generator
10 - 6.1 Characteristics and performance of the ESD generator
11 - 6.2 Verification of the characteristics of the ESD generator
12 - 7 Test set-up
12 - 7.1 Test set-up for tests performed in laboratories
13 - 7.1.1 Table-top equipment
13 - 7.1.2 Floor-standing equipment
13 - 7.1.3 Test method for ungrounded equipment
14 - 7.2 Test set-up for post-installation tests
15 - 8 Test procedure
15 - 8.1 Laboratory reference conditions
15 - 8.1.1 Climatic conditions
15 - 8.1.2 Electromagnetic conditions
15 - 8.2 EUT exercising
16 - 8.3 Execution of the test
16 - 8.3.1 Direct application of discharges to the EUT
18 - 8.3.2 Indirect application of the discharge
18 - 9 Evaluation of test results
19 - 10 Test report
27 - Annex A - Explanatory notes
27 - A.1 General considerations
27 - A.2 Influences of the environmental conditions on the levels of charge
28 - A.3 Relationship of environmental levels to air and contact discharge
28 - A.4 Selection of test levels
29 - A.5 Selection of test points
29 - A.6 Technical rationale for the use of the contact discharge method
29 - A.7 Selection of elements for the ESD generator
31 - Annex B - Constructional details
31 - B.1 Current-sensing transducer
31 - B.2 Inductive current probe

Establishes a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. This Standard is identical with and has been reproduced from IEC 61000-4-2:2001 Ed 1.2 B.

Committee
TE-003
DocumentType
Standard
ISBN
0 7337 4799 X
Pages
30
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This International Standard relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur from personnel to objects near vital equipment. This standard defines: – typical waveform of the discharge current;– range of test levels;– test equipment;– test set-up;– test procedure.This standard gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation.This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committees of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.In order not to impede the task of coordination and standardization, the product committees or users and manufacturers are strongly recommended to consider (in their future work or revision of old standards) the adoption of the relevant immunity tests specified in this standard.

Standards Relationship
IEC 61000-4-2:1995+AMD1:1998+AMD2:2000 CSV Identical

First published as AS/NZS 61000.4.2:2002.

AS 62052.11-2005 Electricity metering equipment (AC) - General requirements, tests and test conditions Metering equipment (IEC 62052-11, Ed.1.0 (2003) MOD)
AS/NZS 3696.21:2008 Wheelchairs Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and motorized scooters
AS 62052.21-2006 Electricity metering equipment (ac) - General requirements, tests and test conditions Tariff and load control equipment (IEC 62052-21, Ed. 1.0 (2004) MOD)
AS/NZS 61058.1:2008 Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD)
AS/NZS 61000.4.15:2005 Electromagnetic compatibility (EMC) Testing and measurement techniques - Flickermeter - Function and design specifications
AS 2703-2008 Vehicle loop detector sensors
AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS 60947.5.2-2004 Low-voltage switchgear and controlgear Control circuit devices and switching elements - Proximity switches
AS/NZS CISPR 14.2:2013 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Immunity - Product family standard
AS 60947.4.1-2004 Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters
AS/NZS 3947.2:2002 Low-voltage switchgear and controlgear Circuit-breakers
AS 60947.5.1-2004 Low-voltage switchgear and controlgear Control circuit devices and switching elements - Electromechanical control circuit devices
AS 60947.6.2-2004 Low-voltage switchgear and controlgear Multiple function equipment - Control and protective switching devices (or equipment) (CPS)
AS/NZS 61000.4.1:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Overview of IEC 61000-4 series
AS/NZS 61000.6.2:2006 Electromagnetic compatibility (EMC) General standards - Immunity for industrial environments (Reconfirmed 2016)
AS 60947.4.2-2004 Low-voltage switchgear and controlgear Contactors and motor-starters - A.C. semiconductor motor controllers and starters
AS/NZS 3200.2.4:2006 Medical electrical equipment Particular requirements for safety - Cardiac defibrillators
AS/NZS 61000.6.1:2006 Electromagnetic compatibility (EMC) Generic standards - Immunity for residential, commercial and light industrial environments (Reconfirmed 2016)
AS/NZS 3200.1.2:2005 Medical electrical equipment General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 61800.3-2005 Adjustable speed electrical power drive systems EMC requirements and specific test methods (Reconfirmed 2016)
AS/NZS CISPR 20:2006 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement
AS 2578-2009 Traffic signal controllers
ATS 4747.2-2008 Meters for non-urban water supply Specification for closed conduit meters fully charged
AS/NZS CISPR 20:2009 Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measure (Reconfirmed 2017)
AS 7240.10-2007 Fire detection and alarm systems Point-type flame detectors
ATS 4747.3-2008 Meters for non-urban water supply Specifications for open channel meters
AS/NZS 60669.2.1:2013 Switches for household and similar fixed electrical installations Particular requirements - Electronic switches (IEC 60669-2-1, Ed.4.1 (2009) MOD)
AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements
AS 60947.1-2004 Low-voltage switchgear and controlgear General rules
AS 60947.2-2005 Low-voltage switchgear and controlgear - Circuit-breakers
AS 60947.8-2005 Low-voltage switchgear and controlgear - Control units for built-in thermal protection (PTC) for rotating electrical machines

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.