AS/NZS 61558.2.6:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-05-2024

Superseded by

AS/NZS 61558.2.6:2009

Published date

11-06-2001

€51.53
Excluding VAT

Specifies safety requirements for approval and test purposes for safety isolating transformers. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-6:1997.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 4073 1
Pages
10
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Replacement:This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, air-cooled safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz, the rated output not exceeding:– 10 kVA for single-phase transformers;– 16 kVA for polyphase transformers.This standard is also applicable to safety isolating transformers without limitation of the rated output; however such transformers are considered as special transformers and are subjected to an agreement between the purchaser and the supplier.The no-load output voltage and the rated output voltage does not exceed:50 V a.c. r.m.s. and/or 120 V ripple-free d.c.between conductors or between any conductor and earth.This standard is applicable to dry type transformers. The windings may be encapsulated or non-encapsulated.

AS 3108 first published in Australia in part as AS C126-1939.
Second edition 1958.
AS C167 first published 1962.
Revised and redesignated AS 3167-1981 (withdrawn 1987).
AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989).
AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984.
Revised, amalgamated and redesignated AS 3108-1990.
First published in New Zealand as NZS/AS 3108:1990.
Jointly revised and designated as Joint Standard AS/NZS 3108:1994.
Jointly revised and redesignated in part as AS/NZS 61558.2.6:2001.

AS/NZS 3112:2000 Approval and test specification - Plugs and socket-outlets
AS 1621.3.1-1988 Pressure-sensitive adhesive electrical tapes Plasticized polyvinyl chloride tapes with non-thermosetting adhesive
AS 1621.3.3-1988 Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with non-thermosetting adhesive
AS 1621.3.2-1988 Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with thermosetting adhesive
AS 2768-1985 Electrical insulating materials - Evaluation and classification based on thermal endurance
AS/NZS 3250:1995 Approval and test specification - Mains operated electronic and related equipment for household and similar general use
AS 2752-1985 Preferred numbers and their use
AS 1621.2-1988 Pressure-sensitive adhesive electrical tapes Methods of test
AS/NZS 3947.7.1:2001 Low-voltage switchgear and controlgear Ancillary equipment - Terminal blocks for copper conductors
AS/NZS 3191:1996 Approval and test specification - Electric flexible cords
AS/NZS 4898:1997 Approval and test specification - Circuit-breakers for overcurrent protection for household and similar installations
AS 2005.21.1-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts
AS 2005.20-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Common requirements
AS 3109.1-1987 Approval and test specification - Appliance couplers for household and similar general purposes - General requirements
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 1104-1978 Informative symbols for use on electrical and electronic equipment
AS/NZS 60998.1:1998 Connecting devices for low voltage circuits for household and similar purposes General requirements
AS/NZS 4695.707:1996 Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source
AS/NZS 4695.2.11:1996 Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance
AS 2374.1-1997 Power transformers General
AS/NZS 60998.2.2:1998 Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screwless-type clamping units
AS/NZS 4695.2.10:1996 Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General
AS 1621.1-1988 Pressure-sensitive adhesive electrical tapes - General requirements
AS/NZS 60998.2.1:1998 Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units
AS/NZS 3139.1:1995 Approval and test specification - Switches for appliances General requirements
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1621.3.5-1988 Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes with thermosetting adhesive
AS 1621.3.4-1988 Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes, creped, with thermosetting adhesive
AS/NZS 4695.112:1996 Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions
AS 2005.30-1991 Low voltage fuses - Fuses with enclosed fuse-links - Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)

AS 2703-2008 Vehicle loop detector sensors
AS 2865-2009 Confined spaces
AS/NZS 3439.4:2009 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 60598.2.22:2005 Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD)
AS/NZS 4879.1:2008 Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3136:2001 Approval and test specification - Electrical equipment for spa and swimming pools
AS/NZS 3004.1:2008 Electrical installations - Marinas and recreational boats Marinas
AS 3533.2-2009 Amusement rides and devices Operation and maintenance
AS 3533.1-2009 Amusement rides and devices Design and construction
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS/NZS 3100:2009
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS 2832.5-2008 Cathodic protection of metals Steel in concrete structures
AS/NZS 3350.1:2002 Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.