    Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber

    Available format(s):  PDF

    Superseded date:  05-01-2022

    Language(s):  English

    Published date:  01-06-2016

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 06.01, 2017 Defines a small environmental chamber and the conditions of operation to evaluate reproducibly in a 4-week period the relative resistance of paint films to surface mold fungi, mildew growth in a severe interior environment.

    Scope - (Show below) - (Hide below)

    1.1This test method describes a small environmental chamber and the conditions of operation to evaluate reproducibly in a 4-week period the relative resistance of paint films to surface mold fungi, mildew growth in a severe interior environment. The apparatus is designed so it can be easily built or obtained2 by any interested party and will duplicate results obtained in a large tropical chamber.

    1.2This test method can be used to evaluate the comparative resistance of interior coating to accelerated mildew growth. Performance at a certain rating does not imply any specific period of time for a fungal free coating. However, a better rated coating nearly always performs better in actual end use.

    Note 1:This test method is intended for the accelerated evaluation of an interior coatings’ resistance to fungal defacement. Use of this test method for evaluating exterior coatings’ performance has not been validated, nor have the limitations for such use been determined. If this test method is to be used for the testing of an exterior coating system, a precautionary statement regarding interpretation of results as being outside of the scope of this test method must be included. Any accelerated weathering (leaching, weathering machine exposure, etc.) should be reported and should also bear reference to the fact that it is beyond the current scope of this test method.

    1.3Temperature and humidity must be effectively controlled within the relatively narrow limits specified in order for the chamber to function reproducibly during the short test period. Severity and rate of mold growth on a film is a function of the moisture content of both the film and the substrate. A relative humidity of 95 ± 3 % at a temperature of 32.5 ± 1°C (90 ± 2°F ) is necessary for test panels to develop rapidly and maintain an adequate moisture level to support mold growth.

    1.4The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

    1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee D 01
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    MIL-PRF-24596 Revision B:2009 COATING COMPOUNDS, NONFLAMING, FIRE-RESISTANT
    A-A-50557 Base Document:1996 PRIMER, WATER-BORNE, ACRYLIC OR MODIFIED ACRYLIC, FOR METAL SURFACES
    A-A-3067 Base Document:1996 PAINT: ALKYD, EXTERIOR, LOW VOC
    A-A-3126 Base Document:1972 COATING SYSTEM: TILE-LIKE HIGH PERFORMANCE ARCHITECTURAL
    A-A-3120 Base Document:1997 PAINT: FOR SWIMMING POOLS
    MIL-P-28578 Revision B:1988 PAINT, WATER REDUCIBLE, SEMI-GLOSS EXTERIOR AND INTERIOR
    MIL-PRF-24763 Revision B:2009 ENAMEL, EMULSION TYPE, FOR SHIPBOARD USE
    FM 2510 : 2014 FLOOD ABATEMENT EQUIPMENT
    MIL-C-47002 Revision A:1991 COATING, POLYURETHANE, SINGLE COMPONENT SYSTEM
    TT-P-24 Revision E:1985 PAINT, OIL (EXTERIOR CONCRETE AND MASONRY
    A-A-3059 Base Document:1997 PAINT: PHOTOLUMINESCENT, NONRADIOACTIVE, INTERIOR
    ASTM C 1705/C1705M : 2009 : R2016 Standard Specification for Structural Cementitious Panels
    ASTM E 1795 : 2017 : REDLINE Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings
    TT-P-1728 Revision A:1974 PAINT, LATEX-BASE, INTERIOR, FLAT, DEEP TONE
    ASTM E 1797 : 2012 Standard Specification for Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings
    ASHRAE 62.1 : 2016 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
    ASTM C 1705/C1705M : 2009 Standard Specification for Structural Cementitious Panels
    TT-E-2784 Revision A:1991 ENAMEL (ACRYLIC EMULSION, EXTERIOR GLOSS AND SEMIGLOSS)
    TT-P-29 Revision K:1991 PAINT, LATEX
    12/30266170 DC : 0 BS EN 15534-1 - COMPOSITES MADE FROM CELLULOSE-BASED MATERIALS AND THERMOPLASTICS (USUALLY CALLED WOOD-POLYMER COMPOSITES (WPC) OR NATURAL FIBRE COMPOSITES (NFC)) - PART 1 : TEST METHODS FOR CHARACTERISATION OF COMPOUNDS AND PRODUCTS
    TT-P-001957 Base Document:1984 PAINT, LATEX (BACTERIOSTATIC AND FUNGISTATIC)
    ASTM D 3730 : 2017 : REDLINE Standard Guide for Testing High-Performance Interior Architectural Wall Coatings
    TT-P-1510 Revision A:1975 PAINT, LATEX, EXTERIOR, FOR WOOD SURFACES, WHITE AND TINTS
    CGSB-1.189 : 2000 EXTERIOR ALKYD PRIMER FOR WOOD
    TT-P-650 Revision D:1988 PRIMER COATING, LATEX BASE, INTERIOR, WHITE (FOR GYPSUM WALLBOARD, OR PLASTER)
    ASTM C 1278/C1278M : 2017 : REDLINE Standard Specification for Fiber-Reinforced Gypsum Panel
    TT-P-002119 Base Document:1980 PAINT, LATEX BASE, HIGH TRAFFIC AREA, FLAT AND EGGSHELL FINISH (LOW LUSTRE), (FOR INTERIOR USE)
    A-A-2994 Base Document:1996 PRIMER COATING, INTERIOR, FOR WALLS AND WOOD
    TT-S-001992 Base Document:1975 STAIN, LATEX, EXTERIOR FOR WOOD SURFACES
    A-A-59528 Base Document:1999 SHOE, MOLDERS
    ASTM D 5324 : 2016 : REDLINE Standard Guide for Testing Water-Borne Architectural Coatings
    ASTM E 3152 : 2018 Standard Guide for Standard Test Methods and Practices Available for Determining Antifungal Activity on Natural or Synthetic Substrates Treated with Antimicrobial Agents
    SSPC-PAINT 46 : 2015 ELASTOMERIC, WATER BASED, HIGH BUILD, FLAT, PERFORMANCE-BASED COATING FOR MASONRY AND CONCRETE
    NASA STD 6012 : 2012 CORROSION PROTECTION FOR SPACE FLIGHT HARDWARE
    ASTM C 1177/C1177M : 2017 : REDLINE Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing
    A-A-3185 Base Document:2001 PAINT, LATEX (CONTAINING POST-CONSUMER MATERIAL)
    TT-E-505 Revision B:1985 ENAMEL, (ODORLESS, ALKYD, INTERIOR, HIGH GLOSS)
    A-A-3058 Base Document:1996 PAINT, INTERIOR, FIRE RETARDANT
    ASTM D 5590 : 2017 : REDLINE Standard Test Method for Determining the Resistance of Paint Films and Related Coatings to Fungal Defacement by Accelerated Four-Week Agar Plate Assay
    MIL E 24763 : A ENAMEL, EMULSION TYPE, FOR SHIPBOARD USE
    TT-P-1511 Revision B:1981 PAINT, LATEX (GLOSS & SEMIGLOSS, TINTS & WHITE) (FOR INTERIOR USE)
    ASTM D 6763 : 2016 : REDLINE Standard Guide for Testing Exterior Wood Stains and Clear Water Repellents
    ASTM E 1797 : 2012 : R2017 : EDT 1 Standard Specification for Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings
    ANSI/EIMA 99A : 2001 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
    A-A-3183 Base Document:2000 PAINT, LATEX, EXTERIOR, (FOR WOOD AND MASONRY)
    MIL-DTL-32237 Revision C:2016 BOOT, COMBAT, HOT WEATHER ARMY
    TT-C-001951 Base Document:1976 COATING, CLEAR (SATIN FINISH), POLYURETHANE, LATEX, FOR INTERIOR USE
    I.S. EN 15534-1:2014 COMPOSITES MADE FROM CELLULOSE-BASED MATERIALS AND THERMOPLASTICS (USUALLY CALLED WOOD-POLYMER COMPOSITES (WPC) OR NATURAL FIBRE COMPOSITES (NFC)) - PART 1: TEST METHODS FOR CHARACTERISATION OF COMPOUNDS AND PRODUCTS
    BS EN 15534-1 : 2014 COMPOSITES MADE FROM CELLULOSE-BASED MATERIALS AND THERMOPLASTICS (USUALLY CALLED WOOD-POLYMER COMPOSITES (WPC) OR NATURAL FIBRE COMPOSITES (NFC)) - PART 1: TEST METHODS FOR CHARACTERISATION OF COMPOUNDS AND PRODUCTS
    MIL-P-28577 Revision B:1988 PRIMER, WATER REDUCIBLE, CORROSION RESISTANT, FOR METAL SURFACES
    TT-P-001984 Base Document:1975 PRIMER COATING, LATEX BASE, EXTERIOR, UNDERCOAT FOR WOOD, WHITE AND TINTS
    ASTM C 1396/C1396M : 2017 : REDLINE Standard Specification for Gypsum Board
    ASTM D 7584 : 2016 : REDLINE Standard Test Method for Evaluating the Resistance of the Surface of Wet Blue and Wet White to the Growth of Fungi in an Environmental Chamber

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective