ASTM D 470 : 2013 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable
04-03-2021
English
01-02-2013
CONTAINED IN VOL. 10.01, 2017 Defines procedures for testing crosslinked insulations and jackets for wire and cable.
Committee |
D 09
|
DocumentType |
Redline
|
Pages |
32
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1These test methods cover procedures for testing crosslinked insulations and jackets for wire and cable. To determine the test to be made on the particular insulation or jacket, refer to the product specification for that type. These test methods do not apply to the class of products known as flexible cords.
1.2In many instances the insulation or jacket cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated or jacketed wire or cable in these test methods solely to determine the relevant property of the insulation or jacket and not to test the conductor or completed cable.
1.3The procedures appear in the following sections:
Sections | |
AC and DC Voltage Withstand Tests | |
Capacitance and Dissipation Factor Tests | |
Cold Bend | |
Cold Bend, Long-Time Voltage Test on Short Specimens | |
Double AC Voltage Test on Short Specimens | |
Electrical Tests of Insulation | |
Heat Distortion Test | |
Horizontal Flame Test | |
Insulation Resistance Tests on Completed Cable | |
Mineral Filler Content, Determination of | |
Ozone Resistance Test | |
Partial-Discharge Test | |
Physical Tests of Insulation and Jacket Compounds | |
Surface Resistivity Test | |
Track Resistance Test | |
U-Bend Discharge Test | |
Water Absorption Test | |
Water Absorption Test, Accelerated | |
Water Absorption Test on Fibrous Coverings |
1.4Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in the parentheses are for information only.
1.5This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards see Section 4.
IEEE 1133-1988 | IEEE Application Guide for Evaluating Nonceramic Materials for High-Voltage Outdoor Applications |
ASTM D 2770 : 2001 | Standard Specification for Ozone-Resisting Ethylene-Propylene Rubber Integral Insulation and Jacket for Wire and Cable (Withdrawn 2007) |
ASTM D 4313 : 2017 : REDLINE | Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Crosslinked Chlorinated Polyethylene (CM) Jackets For Wire and Cable |
MIL C 17 : G | CABLES, RADIO FREQUENCY, FLEXIBLE AND SEMIRIGID, GENERAL SPECIFICATION FOR |
MIL-PRF-85045-30 Base Document:2009 | CABLE, FIBER OPTIC, RADIATION HARDENED, CABLE CONFIGURATION TYPE 1 (BUFFERED FIBER), APPLICATION E (GROUND TACTICAL), CABLE CLASS SM, (METRIC) |
MIL-C-23553 Revision B:1976 | CABLES, ELECTRICAL, ALUMINUM FOIL SHIELDED PAIRS |
ASTM D 3089 : 1997 : R2008 | Standard Practice for Determining the A-D Dimension of Aerosol Valve Dip Tubes |
ASTM D 4244 : 1995 | Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Acrylonitrile-Butadiene/Poly(vinyl Chloride) (NBR/PVC) Jackets for Wire and Cable |
ASTM D 2656 : 2013 : REDLINE | Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V |
MIL-PRF-85045 Revision G:2014 | Cables, Fiber Optic, General Specification for |
MIL-DTL-24643 Revision C:2009 | Cables, Electric, Low Smoke, Halogen-Free, for Shipboard Use, General Specification for |
MIL-DTL-24640 Revision C:2011 | CABLES, LIGHTWEIGHT, LOW SMOKE, ELECTRIC, FOR SHIPBOARD USE, GENERAL SPECIFICATION FOR |
MIL C 915 : F | CABLE AND CORD ELECTRICAL, FOR SHIPBOARD USE GENERAL SPECIFICATIONS FOR |
MIL-PRF-85045-8 Revision B:2008 | CABLE, FIBER OPTIC, RADIATION HARDENED, CABLE CONFIGURATION TYPE 1 (BUFFERED FIBER), APPLICATION E (GROUND TACTICAL), CABLE CLASS MM, (METRIC) |
ASTM D 3555 : 2007 : R2018 | Standard Specification for Track-Resistant Black Crosslinked Polyethylene Insulation for Wire and Cable, 90 °C Operation |
ASTM D 4244 : 1995 : R2001 | Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Acrylonitrile-Butadiene/Poly(Vinyl Chloride) (NBR/PVC) Jackets for Wire and Cable (Withdrawn 2007) |
ASTM D 866 : 1999 : R2004 | Standard Specification for Crosslinked Styrene-Butadiene (SBR) Synthetic Rubber Jacket for Wire and Cable (Withdrawn 2009) |
ASTM D 3555 : 2007 | Standard Specification for Track-Resistant Black Crosslinked Polyethylene Insulation for Wire and Cable, 90°C Operation |
ASTM D 4245 : 2008 : R2013 | Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable, 90°C Dry/75°C Wet Operation |
ASTM D 345 : 2002 | Side bearings of the freight wagon bogies. General specifications |
NEMA WC 55 : 1992(R1999) | INSTRUMENTATION CABLES AND THERMOCOUPLE WIRE |
MIL-PRF-87819 Revision B:2009 | HEADSET-MICROPHONE, (HEARING PROTECTIVE TYPE, HIGH AND MODERATE AMBIENT NOISE LEVELS), GENERAL SPECIFICATION FOR |
MIL C 24643 : A | CABLES AND CORDS ELECTRIC, LOW SMOKE FOR SHIPBOARD USE, GENERAL SPECIFICATION FOR |
MIL C 85045 : E | CABLES, FIBER OPTICS, (METRIC), GENERAL SPECIFICATION FOR |
C22.2 NO. 174-18 | Cables and cable glands for use in hazardous locations |
ASTM D 4247 : 1999 | Standard Specification for General-Purpose, Black Heavy-Duty, and Black Extra-Heavy-Duty Crosslinked Polychloroprene Jackets For Wire and Cable |
ASTM D 4314 : 2012 | Standard Specification for General-Purpose, Heavy-Duty, and Extra-Heavy-Duty Crosslinked Chlorosulfonated Polyethylene (CSM) Jackets For Wire and Cable (Withdrawn 2017) |
ASTM D 866 : 1999 | Standard Specification for Crosslinked Styrene-Butadiene (SBR) Synthetic Rubber Jacket for Wire and Cable |
NASA KSC SPEC E 0031 : 2008 | CABLES, ELECTRICAL, SPECIFICATION FOR |
NASA KSC SPEC E 0024 : 2008 | CABLE, ELECTRICAL, SHIELDED, JACKETED, FOR HARNESS ASSEMBLIES, GENERAL SPECIFICATION FOR |
ASTM D 1679 : 2002 | Standard Specification for Synthetic Rubber Heat-and Moisture-Resisting Insulation for Wire and Cable, 75°C Operation (Withdrawn 2006) |
MIL C 28781 : B | CABLE, ELECTRICAL, SPECIAL PURPOSE, SHORE USE |
MIL-DTL-55425 Revision E:2011 | CABLE, TELEPHONE WF-16()/U |
MIL C 55425 : C | CABLE, TELEPHONE WF-16 ()/U |
ASTM D 3555 : 2007 : R2013 | Standard Specification for Track-Resistant Black Crosslinked Polyethylene Insulation for Wire and Cable, 90 °C Operation |
MIL-C-19547 Revision B:1969 | CABLE, ELECTRICAL, SPECIAL PURPOSE, SHORE USE |
ASTM D 4245 : 2008 | Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable, 90°C Dry/75°C Wet Operation |
MIL-DTL-28781 Revision E:2011 | CABLE, ELECTRICAL, SPECIAL PURPOSE SHORE USE |
MIL C 24640 : A | CABLE, LIGHT WEIGHT, ELECTRIC, LOW SMOKE, FOR SHIPBOARD USE GENERAL SPECIFICATION FOR |
MIL-PRF-6106 Revision P:2014 | Relays, Electromagnetic General Specification for |
ASTM D 2768 : 1995 : R2001 | Standard Specification for General-Purpose Ethylene-Propylene Rubber Jacket for Wire and Cable (Withdrawn 2007) |
ASTM D 4246 : 2014 : REDLINE | Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable, 90°C Operation |
ASTM F 855 : 2017 : REDLINE | SPECIFICATIONS FOR TEMPORARY PROTECTIVE GROUNDS TO BE USED ON DE-ENERGIZED ELECTRIC POWER LINES AND EQUIPMENT |
ASTM D 4325 : 2013 : REDLINE | Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes |
ASTM D 353 : 1989 | Specification for Natural Rubber Insulation for Wire and Cable, 60 |
ASTM D 4247 : 1999 : R2004 | Standard Specification for General-Purpose, Black Heavy-Duty, and Black Extra-Heavy-Duty Crosslinked Polychloroprene Jackets for Wire and Cable (Withdrawn 2006) |
MIL-DTL-49285 Revision A:2008 | CABLES, SPECIAL PURPOSE, ELECTRICAL, ALUMINUM FOIL SHIELDED PAIRS, TRIPLETS, OR QUADS, GENERAL SPECIFICATION FOR |
MIL DTL 17 : J | CABLES, RADIO FREQUENCY, FLEXIBLE AND SEMIRIGID, GENERAL SPECIFICATION FOR |
DSCC 09001 : B | CABLE, FIBER OPTIC, MIXED FIBER (MULTIMODE AND SINGLE MODE FIBERS) |
CSA C22.2 No. 2556 : 2015 | WIRE AND CABLE TEST METHODS |
ASTM D 2768 : 1995 | Standard Specification for General-Purpose Ethylene-Propylene Rubber Jacket for Wire and Cable |
ASTM D 1711 : 2015 : REDLINE | Standard Terminology Relating to Electrical Insulation |
ASTM D 2526 : 2002 | Standard Specification for Ozone-Resisting Silicone Rubber Insulation for Wire and Cable (Withdrawn 2006) |
ASTM D 2802 : 2014 : REDLINE | Standard Specification for Ozone-Resistant Ethylene-Alkene Polymer Insulation<brk/> for Wire and Cable |
ASTM D 2132 : 2012-02 | TEST METHOD FOR DUST-AND-FOG TRACKING AND EROSION RESISTANCE OF ELECTRICAL INSULATING MATERIALS |
ASTM D 1711 : 2015 : REDLINE | Standard Terminology Relating to Electrical Insulation |
ASTM D 5207 : 2014 : REDLINE | Standard Practice for Confirmation of 20–mm (50–W) and 125–mm (500–W) Test Flames for Small-Scale Burning Tests on Plastic Materials |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
ICEA T 24 380 : 2013 | PARTIAL DISCHARGE TEST PROCEDURE |
ASTM D 5423 : 2014 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.