Electrical apparatus for potentially explosive atmospheres Flameproof enclosure \'d\'
Hardcopy , PDF
01-06-2003
English
30-12-1977
Apparatus placed in an enclosure that can withstand an internal explosion of an explosive mixture without igniting an explosive atmosphere surrounding the enclosure. Supplements Part 1.
Committee |
EXL/31
|
DevelopmentNote |
Superseded by BS EN 50018, but remains current until a date of withdrawal has been agreed by CENELEC
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 50018 : 2000 AMD 1 2002 | Identical |
IEC 60079-1:2014 RLV | Similar to |
NFC 23 518 : 82 AMD 3 1986 | Identical |
VDE 0170-5 : 2015-04 | Corresponds |
BS 7924:1999 | Code of practice for the repair and overhaul of certified electrical apparatus intended for use in mines susceptible to firedamp |
BS 6742-1:1987 | Electrostatic painting and finishing equipment using flammable materials Electrostatic painting and finishing equipment using flammable materials. Specification for hand-held spray guns and associated apparatus |
BS 6709:1986 | Specification for interconnection of electrical apparatus, constructed to two or more British Standards, for use in mines susceptible to firedamp |
BS 7117-1:1991 | Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Specification for construction |
BS 6020-2:1981 | Instruments for the detection of combustible gases Specification for safety and performance requirements for Group I instruments reading up to 5% methane in air |
BS 6351-1:1983 | Electric surface heating Specification for electric surface heating devices |
DEFSTAN 40-15/1(1994) : 1994 | SAFETY CONDITIONS FOR MOBILE MECHANICAL HANDLING EQUIPMENT FOR USE IN HAZARDOUS AREAS |
EEMUA 181 : 1995 | GUIDE TO RISK BASED ASSESSMENTS OF IN-SITU LARGE EX 'E' AND EX 'N' MACHINES |
BS 5345-1:1989 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) General recommendations |
BS 6680:1985 | Specification for flameproof equipment for diesel engines for use in coal mines and other mines susceptible to firedamp |
BS 5345-3:1979 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection \'d\'. Flameproof enclosure |
BS 5908:1990 | Code of practice for fire precautions in the chemical and allied industries |
BS 5501-1:1977 | Electrical apparatus for potentially explosive atmospheres General requirements |
BS 4999-101:1987 | General requirements for rotating electrical machines Specification for rating and performance |
BS 5502-25:1991 | Buildings and structures for agriculture Code of practice for design and installation of services and facilities |
BS 5000-17:1981 | Rotating electrical machines of particular types or for particular applications Machines with flameproof enclosure |
BS 848-5:1986 | Fans for general purposes Guide for mechanical and electrical safety |
BS 6704:1987 | Code of Practice for selection, installation and maintenance of intrinsically safe electrical equipment in coal mines |
BS 7535:1992 | Guide to the use of electrical apparatus complying with BS 5501 or BS 6941 in the presence of combustible dusts |
BS 6020-3:1982 | Instruments for the detection of combustible gases Specification for safety and performance requirements for Group I instruments reading up to 100% methane |
EEMUA 186 : 2016 | A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS 4683-2:1971 | Specification for electrical apparatus for explosive atmospheres The construction and testing of flameproof enclosures of electrical apparatus |
BS 5501-7:1977 | Electrical apparatus for potentially explosive atmospheres Intrinsic safety \'i\' |
BS 6020-1:1981 | Instruments for the detection of combustible gases Specification for general requirements and test methods |
BS 7117-1:1989 | Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Specification for construction |
BS 5908:1980 | Code of practice for fire precautions in chemical plant |
BS 7019:1989 | Specification for fully screened 400 A bolted flameproof cable couplers and adaptors for use on systems up to and including 6.6 kV, primarily for use in mines |
BS 6739:1986 | Code of practice for instrumentation in process control systems: installation design and practice |
BS 5067:1985 | Specification for flameproof transformers for use in mines |
BS 5126-1:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for direct-on-line motor starters |
BS 3905:1995 | Specification for 3.8/6.6 kV, 300 A bolted flameproof cable couplers and adaptors, for use in coal mines. |
BS 5125:1990 | Specification for 50 A 650 V flameproof, restrained and bolted plugs and sockets for use in coal mines |
BS 6704:1996 | Code of practice for selection, installation and maintenance of intrinsically safe electrical equipment in coal mines |
BS 5126-2:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for circuit breaker units |
BS 3454:1995 | Specification for 1.9/3.3 kV, 300 A bolted flameproof cable couplers and adaptors (including 380/660 V and 640/1100 V, 300 A adaptors) for use in coal mines |
BS 5126-4:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled transformers to power drilling machines |
BS 5126-3:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled lighting transformer units |
BS 7117-3:1991 | Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Guide to maintenance after installation |
BS 7244:1990 | Specification for flame arresters for general use |
BS 7348:1990 | Specification for electrical apparatus for the detection of combustible gases in domestic premises |
BS 5501-6:1977 | Electrical apparatus for potentially explosive atmospheres Increased safety \'e\' |
BS 1134-1:1972 | Method for the assessment of surface texture Method and instrumentation |
BS 903-A26:1969 | Physical testing of rubber Determination of hardness |
BS 5501-1:1977 | Electrical apparatus for potentially explosive atmospheres General requirements |
BS 3643-3:1967 | ISO metric screw threads. Limits and tolerances for fine pitch threads (constant pitch series) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.