BS 7735:1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Guide to loading of oil-immersed power transformers
Hardcopy , PDF
31-12-2010
English
15-03-1994
Committees responsible
Foreword
Section 1. General
1.1 Scope
1.2 Object
1.3 Definitions
1.4 General limitations and effect of loading beyond
nameplate rating
1.5 Specific limitations for distribution transformers
1.6 Specific limitations for medium power transformers
1.7 Specific limitations for large power transformers
Section 2. Determination of temperatures
2.1 Symbols
2.2 Direct measurement of hot-spot temperature
2.3 Assumed thermal characteristics
2.4 Steady-state temperature equations
2.5 Transient temperature equations
2.6 Thermal ageing of transformer insulation
2.7 Ambient temperature
2.8 Computer program
Section 3. Loading tables
3.1 Limitations applicable to loading tables
3.2 Method of representing an actual load cycle by an
equivalent two-step rectangular load cycle
3.3 Normal continuous loading
3.4 Normal cyclic loading
3.5 Emergency cyclic loading
Annexes
A. Equivalent rating for auto-transformers
B. Alternative method for determining the winding oil
average temperature rise from temperature rise test
measurements
C. Information to be supplied with enquiry and order
D. Calculation of parameters for sinusoidal variation
of ambient temperature
E. Example of simplified application of the guide
Tables
1. Current and temperature limits applicable to loading
beyond nameplate rating
2. Thermal characteristics used for the calculation of
loading table sin section 3
3. Correction for increase in ambient temperature due
to enclosure
4. Data relating to calculation over a single day with
a constant weighted ambient temperature
5. Data relating to calculation over a full year with
double sinusoidal variation of ambient temperature
and three different load profiles
6. Acceptable load factor for continuous duty K24 at
different ambient temperatures (ON, OF and OD
cooling)
7. ONAN distribution transformers: t = 0,5 h Permissible
duties and corresponding daily loss of life
8. ONAN distribution transformers: t = 1 h Permissible
duties and corresponding daily loss of life
9. ONAN distribution transformers: t = 2 h Permissible
duties and corresponding daily loss of life
10. ONAN distribution transformers: t = 4 h Permissible
duties and corresponding daily loss of life
11. ONAN distribution transformers: t = 8 h Permissible
duties and corresponding daily loss of life
12. ONAN distribution transformers: t = 24 h Permissible
duties and corresponding daily loss of life
13. ON medium and large power transformers: t = 0,5 h
Permissible duties and corresponding daily loss of
life
14. ON medium and large power transformers: t = 1 h
Permissible duties and corresponding daily loss of
life
15. ON medium and large power transformers: t = 2 h
Permissible duties and corresponding daily loss of
life
16. ON medium and large power transformers: t = 4 h
Permissible duties and corresponding daily loss of
life
17. ON medium and large power transformers: t = 8 h
Permissible duties and corresponding daily loss of
life
18. ON medium and large power transformers: t = 24 h
Permissible duties and corresponding daily loss of
life
19. OF medium and large power transformers: t = 0,5 h
Permissible duties and corresponding daily loss of
life
20. OF medium and large power transformers: t = 1 h
Permissible duties and corresponding daily loss of
life
21. OF medium and large power transformers: t = 2 h
Permissible duties and corresponding daily loss of
life
22. OF medium and large power transformers: t = 4 h
Permissible duties and corresponding daily loss of
life
23. OF medium and large power transformers: t = 9 h
Permissible duties and corresponding daily loss of
life
24. OF medium and large power transformers: t = 24 h
Permissible duties and corresponding daily loss of
life
25. OD medium and large power transformers: t = 0,5 h
Permissible duties and corresponding daily loss of
life
26. OD medium and large power transformers: t = 1 h
Permissible duties and corresponding daily loss of
life
27. OD medium and large power transformers: t = 2 h
Permissible duties and corresponding daily loss of
life
28. OD medium and large power transformers: t = 4 h
Permissible duties and corresponding daily loss of
life
29. OD medium and large power transformers: t = 8 h
Permissible duties and corresponding daily loss of
life
30. OD medium and large power transformers: t = 24 h
Permissible duties and corresponding daily loss of
life
Figures
1. Thermal diagram
2. Correction between weighted and average ambient
temperature as a function of the temperature range
3. Logic diagram of a computer program for calculation
of an acceptable loading factor
4. Equivalent two-step load cycle
5. Load cycle with one peak
6. Load cycle with two peaks of equal amplitude and
different duration
7. Load cycle with peaks in close succession
8. Illustration of example 2
9. ONAN distribution transformers - Permissible duties
for normal loss of life
10. ON medium and large power transformers - Permissible
duties for normal loss of life
11. OF medium and large power transformers - Permissible
duties for normal loss of life
12. OD medium and large power transformers - Permissible
duties for normal loss of life
A.1 Auto-transformers: limitations in rated power Sr and
short-circuit impedance zr
B.1 Determination of average winding rise, gradient and
winding time constant from resistance cooling curve
B.2 Determination of effective oil time constant, tau o,
from oil heating curve
D.1 Definition of the parameters for sinusoidal
variation of ambient temperature
D.2 Logic diagram of a computer program for the
calculation of parameters for sinusoidal variation
of ambient temperature
E.1 Example of simplified instructions for loading
beyond nameplate rating
Applies to transformers covered by BS 171.
Committee |
PEL/14
|
DevelopmentNote |
Also numbered as IEC 60354 Supersedes 87/20356 DC and BS CP1010(1975) (10/2005)
|
DocumentType |
Standard
|
Pages |
78
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
BS 171-1:1978 | Power transformers General |
BS 171-2:1978 | Power transformers Specification for temperature rise requirements |
BS 171-3:1987 | Power transformers Specification for insulation levels and dielectric tests |
BS 171-4:1978 | Power transformers Specification for tappings and connections |
BS 171-5:1978 | Power transformers Specification for ability to withstand short circuit |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.