Workplace exposure. Assessment of sampler performance for measurement of airborne particle concentrations General requirements
Hardcopy , PDF
English
30-06-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
6 Test methods
7 Types of evaluation
8 Instructions for use
9 Marking, quality control
Annex A (normative) - Calculation of expanded
uncertainty for a measuring procedure
Bibliography
Describes performance requirements that are specific to aerosol samplers, primarily inhalable, thoracic and respirable aerosol samplers.
Committee |
EH/2/2
|
DevelopmentNote |
Supersedes 12/30259163 DC. (06/2014) Together with BS EN 13205-2, BS EN 13205-4, BS EN 13205-5, BS EN 13205-6 and BS PD CEN/TR 13205-3, it supersedes BS EN 13205. (07/2014)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies performance requirements that are specific to aerosol samplers, primarily inhalable, thoracic and respirable aerosol samplers. These performance requirements, which include conformity with the EN 481 sampling conventions, are applicable only to the process of sampling the airborne particles from the air, not to the process of analysing particles collected by the process of sampling. Although analysis of samples collected in the course of testing is usually necessary in order to evaluate the sampler performance, the specified test methods ensure that analytical errors are kept very low during testing and do not contribute significantly to the end result.
This part of EN 13205 specifies how the performance of aerosol measuring procedures is assessed with respect to the general requirements of EN 482, through the combination of errors arising in the sampling, sample transportation/storage and sample preparation/analysis stages.
This part of EN 13205 is applicable to all samplers used for the health-related sampling of particles in workplace air.
This part of EN 13205 is not applicable to the determination of analytical errors and factors related to them (for example the bias, precision and limit of detection of the analytical method). Where the aerosol sampler requires the use of an external (rather than integral) pump, the pump is not subject to the requirements of this part of EN 13205.
Standards | Relationship |
EN 13205-1:2014 | Identical |
EN 14530:2004 | Workplace atmospheres - Determination of diesel particulate matter - General requirements |
ISO 24095:2009 | Workplace air Guidance for the measurement of respirable crystalline silica |
EN 13205-4:2014 | Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 4: Laboratory performance test based on comparison of concentrations |
EN 481:1993 | Workplace atmospheres - Size fraction definitions for measurement of airborne particles |
EN 13205-2:2014 | Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 2: Laboratory performance test based on determination of sampling efficiency |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
ISO 13137:2013 | Workplace atmospheres — Pumps for personal sampling of chemical and biological agents — Requirements and test methods |
EN 13890:2009 | Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods |
EN ISO 13137:2013 | Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods (ISO 13137:2013) |
CEN/TR 15230:2005 | Workplace atmospheres - Guidance for sampling of inhalable, thoracic and respirable aerosol fractions |
ISO 3534-2:2006 | Statistics — Vocabulary and symbols — Part 2: Applied statistics |
EN 13205-5:2014 | Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 5: Aerosol sampler performance test and sampler comparison carried out at workplaces |
EN 1540:2011 | Workplace exposure - Terminology |
CEN/TR 13205-3:2014 | Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 3: Analysis of sampling efficiency data |
EN 13205-6:2014 | Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 6: Transport and handling tests |
ISO 15767:2009 | Workplace atmospheres Controlling and characterizing uncertainty in weighing collected aerosols |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.