• Shopping Cart
    There are no items in your cart

BS EN 13205-1:2014

Current

Current

The latest, up-to-date edition.

Workplace exposure. Assessment of sampler performance for measurement of airborne particle concentrations General requirements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2014

€254.76
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
6 Test methods
7 Types of evaluation
8 Instructions for use
9 Marking, quality control
Annex A (normative) - Calculation of expanded
        uncertainty for a measuring procedure
Bibliography

Describes performance requirements that are specific to aerosol samplers, primarily inhalable, thoracic and respirable aerosol samplers.

Committee
EH/2/2
DevelopmentNote
Supersedes 12/30259163 DC. (06/2014) Together with BS EN 13205-2, BS EN 13205-4, BS EN 13205-5, BS EN 13205-6 and BS PD CEN/TR 13205-3, it supersedes BS EN 13205. (07/2014)
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard specifies performance requirements that are specific to aerosol samplers, primarily inhalable, thoracic and respirable aerosol samplers. These performance requirements, which include conformity with the EN 481 sampling conventions, are applicable only to the process of sampling the airborne particles from the air, not to the process of analysing particles collected by the process of sampling. Although analysis of samples collected in the course of testing is usually necessary in order to evaluate the sampler performance, the specified test methods ensure that analytical errors are kept very low during testing and do not contribute significantly to the end result.

This part of EN 13205 specifies how the performance of aerosol measuring procedures is assessed with respect to the general requirements of EN 482, through the combination of errors arising in the sampling, sample transportation/storage and sample preparation/analysis stages.

This part of EN 13205 is applicable to all samplers used for the health-related sampling of particles in workplace air.

This part of EN 13205 is not applicable to the determination of analytical errors and factors related to them (for example the bias, precision and limit of detection of the analytical method). Where the aerosol sampler requires the use of an external (rather than integral) pump, the pump is not subject to the requirements of this part of EN 13205.

Standards Relationship
EN 13205-1:2014 Identical

EN 14530:2004 Workplace atmospheres - Determination of diesel particulate matter - General requirements
ISO 24095:2009 Workplace air Guidance for the measurement of respirable crystalline silica
EN 13205-4:2014 Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 4: Laboratory performance test based on comparison of concentrations
EN 481:1993 Workplace atmospheres - Size fraction definitions for measurement of airborne particles
EN 13205-2:2014 Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 2: Laboratory performance test based on determination of sampling efficiency
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
ISO 13137:2013 Workplace atmospheres — Pumps for personal sampling of chemical and biological agents — Requirements and test methods
EN 13890:2009 Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods
EN ISO 13137:2013 Workplace atmospheres - Pumps for personal sampling of chemical and biological agents - Requirements and test methods (ISO 13137:2013)
CEN/TR 15230:2005 Workplace atmospheres - Guidance for sampling of inhalable, thoracic and respirable aerosol fractions
ISO 3534-2:2006 Statistics — Vocabulary and symbols — Part 2: Applied statistics
EN 13205-5:2014 Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 5: Aerosol sampler performance test and sampler comparison carried out at workplaces
EN 1540:2011 Workplace exposure - Terminology
CEN/TR 13205-3:2014 Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 3: Analysis of sampling efficiency data
EN 13205-6:2014 Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 6: Transport and handling tests
ISO 15767:2009 Workplace atmospheres Controlling and characterizing uncertainty in weighing collected aerosols

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.