BS EN 14449:2005
Current
The latest, up-to-date edition.
Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard
Hardcopy , PDF
English
10-02-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Product description
4.2 Conformity with the definition of laminated glass
and laminated safety glass
4.3 Determination of the characteristic's
performances
4.4 Durability
4.5 Dangerous substances
5 Evaluation of conformity
5.1 General
5.2 Initial type testing of the product
5.3 Factory production control (FPC) and inspection of
samples in accordance with a prescribed test plan
5.4 Initial inspection of factory and of factory
production control
5.5 Continuous surveillance and assessment of
the factory production control
6 Marking and/or labelling
6.1 General
6.2 Product marking
6.3 Product characteristics
6.4 'Characteristics/performance identification paper'
Annex A (normative) Factory production control
Annex B (informative) Tests for ensuring conformity
Annex C (informative) Laminated safety glass: Mechanical
resistance tests
Annex D (informative) Criteria for deciding if a change
within an assembly requires a new
initial type test
Annex E (informative) Provisions for voluntary involvement
of third party(ies)
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of EU
Construction Products Directive
Bibliography
Includes the evaluation of conformity and the factory production control of laminated glass and laminated safety glass for use in buildings.
Committee |
B/520
|
DevelopmentNote |
Supersedes 02/103123 DC. (03/2006)
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard covers the evaluation of conformity and the factory production control of - EN ISO 12543-2: Laminated safety glass; - EN ISO 12543-3: Laminated glass; inclusive laminated (safety) glass with fire resistant properties. For glass products with electrical wiring or connections for e.g. alarm or heating purposes, this standard covers only wiring subject for electrical potential difference to earth less than 50 V a.c. or less than 75 V d.c.
Standards | Relationship |
DIN EN 14449:2005-07 | Identical |
NF EN 14449 : 2005 | Identical |
NBN EN 14449 : 2005 COR 2005 | Identical |
NS EN 14449 : 2005 AC 2006 | Identical |
UNE-EN 14449:2006 | Identical |
I.S. EN 14449:2005 | Identical |
SN EN 14449 : 2005 | Identical |
UNI EN 14449 : 2005 | Identical |
NEN EN 14449 : 2005 C1 2006 | Identical |
EN 14449:2005 | Identical |
08/30143158 DC : DRAFT AUG 2008 | BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION |
BS 6262-7:2017 | Glazing for buildings Code of practice for the provision of information |
BS 6262-1:2017 | Glazing for buildings General methodology for the selection of glazing |
BS 6510:2010 | Steel-framed windows and glazed doors. Specification |
BS 7412:2007 | Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles |
BS 6262-4:2005 | Glazing for buildings Code of practice for safety related to human impact |
17/30342957 DC : 0 | BS 8297 - DESIGN, MANUFACTURE AND INSTALLATION OF ARCHITECTURAL PRECAST CONCRETE CLADDING - CODE OF PRACTICE |
17/30350485 DC : 0 | BS 6262-4 - GLAZING FOR BUILDINGS - PART 4: CODE OF PRACTICE FOR SAFETY RELATED TO HUMAN IMPACT |
06/30143171 DC : DRAFT SEP 2006 | BS 7412 - PLASTICS WINDOWS AND DOORSETS MADE FROM UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) EXTRUDED HOLLOW PROFILES |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
PREN 13501-5 : DRAFT 2015 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS |
EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
PREN 14179-1 : DRAFT 2014 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 12898:2001 | Glass in building - Determination of the emissivity |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
ISO 12543-3:2011 | Glass in building Laminated glass and laminated safety glass Part 3: Laminated glass |
EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN ISO 12543-3:2011 | Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011) |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
ISO 12543-2:2011 | Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
ISO 12543-1:2011 | Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
ISO 12543-4:2011 | Glass in building Laminated glass and laminated safety glass Part 4: Test methods for durability |
EN ISO 12543-4:2011 | Glass in building - Laminated glass and laminated safety glass - Part 4: Test methods for durability (ISO 12543-4:2011) |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
ISO 12543-6:2011 | Glass in building Laminated glass and laminated safety glass Part 6: Appearance |
EN ISO 12543-5:2011 | Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing (ISO 12543-5:2011) |
ISO 12543-5:2011 | Glass in building Laminated glass and laminated safety glass Part 5: Dimensions and edge finishing |
EN ISO 12543-1:2011 | Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011) |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.