BS EN 14604:2005

Current

Current

The latest, up-to-date edition.

Smoke alarm devices

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2009

€348.24
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
  4.1 Compliance
  4.2 Individual alarm indicator (optional)
  4.3 Mains-on indicator
  4.4 Connection of external ancillary devices
  4.5 Means of calibration
  4.6 User replaceable components
  4.7 Normal power source
  4.8 Standby power source
  4.9 Electrical safety requirements
  4.10 Routine test facility
  4.11 Terminals for external conductors
  4.12 Smoke alarm signals
  4.13 Battery removal indication
  4.14 Battery connections
  4.15 Battery capacity
  4.16 Protection against the ingress of foreign bodies
  4.17 Additional requirements for software controlled smoke
       alarms
  4.18 Inter-connectable smoke alarms
  4.19 Marking and data
5 Tests
  5.1 General
  5.2 Repeatability
  5.3 Directional dependence
  5.4 Initial sensitivity
  5.5 Air movement
  5.6 Dazzling
  5.7 Dry heat
  5.8 Cold (operational)
  5.9 Damp heat (operational)
  5.10 Sulphur dioxide (SO[2]) corrosion
  5.11 Impact
  5.12 Vibration (operational)
  5.13 Vibration (endurance)
  5.14 Electromagnetic Compatibility (EMC), immunity tests
       (operational)
  5.15 Fire sensitivity
  5.16 Battery fault warning
  5.17 Sound output
  5.18 Sounder durability
  5.19 Inter-connectable smoke alarms
  5.20 Alarm silence facility (optional)
  5.21 Variation in supply voltage
  5.22 Battery reversal
  5.23 Back-up power source
  5.24 Electrical safety - assessment and testing to
       determine the adequacy of personal protection
       against hazardous currents passing through the
       human body (electric shock), excessive
       temperature and the start and spread of fire
Annex A (normative) - Smoke tunnel for response threshold
                      value measurements
Annex B (normative) - Test aerosol for response threshold
                      value measurements
Annex C (normative) - Smoke measuring instruments
      C.1 Obscuration meter
      C.2 Measuring ionization chamber (MIC)
Annex D (normative) - Apparatus for dazzling test
Annex E (informative) - Apparatus for impact test
Annex F (normative) - Fire test room
Annex G (normative) - Smouldering pyrolysis wood fire (TF2)
      G.1 Fuel
      G.2 Hotplate
      G.3 Arrangement
      G.4 Heating rate
      G.5 End of test condition
      G.6 Test validity criteria
Annex H (normative) - Glowing smouldering cotton fire (TF3)
      H.1 Fuel
      H.2 Arrangement
      H.3 Ignition
      H.4 End of test condition
      H.5 Test validity criteria
Annex I (normative) - Flaming plastics (polyurethane) fire (TF4)
      I.1 Fuel
      I.2 Arrangement
      I.3 Ignition
      I.4 End of test condition
      I.5 Test validity criteria
Annex J (normative) - Flaming liquid (n-heptane) fire (TF5)
      J.1 Fuel
      J.2 Arrangement
      J.3 Ignition
      J.4 End of test condition
      J.5 Test validity criteria
Annex K (informative) - Information concerning the construction
                        of the smoke tunnel
Annex L (normative) - Alarms suitable for installation in
                       leisure accommodation vehicles (LAVs)
      L.1 Temperature cycle test
Annex M (informative) - Information concerning the construction
                        of the measuring ionization chamber
Annex ZA (informative) - Clauses addressing the provisions of
                         the EU Construction Products Directive
                         (89/106/EEC)
      ZA.1 Scope and relevant clauses
      ZA.2 Procedures for the attestation of conformity of
           smoke alarms covered by this standard
      ZA.3 CE Marking and labelling and accompanying
           documentation
      ZA.4 EC certificate and declaration of conformity
Bibliography

This document specifies requirements, test methods, performance criteria, and manufacturer\'s instructions for smoke alarms that operate using scattered light, transmitted light, or ionization, intended for household or similar residential application. Requirements for smoke alarms suitable for use in leisure accommodation vehicles are also included.

Committee
FSH/12/2
DevelopmentNote
Supersedes BS 5446-1(2000). (09/2005)
DocumentType
Standard
Pages
72
PublisherName
British Standards Institution
Status
Current
Supersedes

This document specifies requirements, test methods, performance criteria, and manufacturer\'s instructions for smoke alarms that operate using scattered light, transmitted light or ionization, intended for household or similar residential application.

This document includes additional requirements for smoke alarms, which are also suitable for use in leisure accommodation vehicles.

For the testing of other types of smoke alarms, or smoke alarms working on different principles, this document should only be used for guidance. AC1 Special features of smoke alarms, such as radio interlinking or special characteristics and developed for specific risks, are not covered by this document. AC1

This document allows, although it does not require, the inclusion within the smoke alarm of facilities for interconnection with other similar smoke alarms and/or accessories, and for alarm silencing. Where such facilities are included, this document specifies applicable requirements.

This document does not cover devices intended for incorporation in systems using separate control and indicating equipment.

NOTE Certain types of smoke alarms contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this document. Such smoke alarms should, however, comply with the applicable national requirements.

12/30260280 DC : 0 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES
15/30253829 DC : 0 BS 3632 - RESIDENTIAL PARK HOMES - SPECIFICATION
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
14/30277275 DC : 0 BS 5446-3 - FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 3: SPECIFICATION FOR FIRE AND CARBON MONOXIDE ALARM SYSTEMS FOR DEAF AND HARD OF HEARING PEOPLE
09/30169955 DC : 0 BS 8511 - CODE OF PRACTICE FOR THE INSTALLATION OF SOLID FUEL HEATING APPLIANCES ON BOATS
BS 8511:2010 Code of practice for the installation of solid fuel heating and cooking appliances in small craft
BS 5446-3:2015 Detection and alarm devices for dwellings Specification for fire alarm and carbon monoxide alarm systems for deaf and hard of hearing people

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
EN 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 573-4:2004 Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 4: Forms of products
EN 54-3:2014 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 573-3:2013 Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 3: Chemical composition and form of products

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.