BS EN 14793:2017
Current
The latest, up-to-date edition.
Stationary source emissions. Demonstration of equivalence of an alternative method with a reference method
31-01-2017
Committee |
EH/2/1
|
DevelopmentNote |
Supersedes 14/30293538 DC & DD CEN/TS 14793. (02/2017)
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes | |
UnderRevision |
This European Standard specifies a procedure to demonstrate the equivalence of an alternative method (AM) with the reference method (RM) or the standard reference method (SRM), both implemented to determine the same measurand. In particular, this European Standard provides the statistical tools and different criteria to evaluate the alternative method. This does not release the body performing the equivalence testing from bearing technical and analytical judgement on the evaluation of the different criteria. Three steps are required for demonstration of equivalence: ? description of the alternative method and setting of the field of application (measurement range and type of gas matrix); ? determination of the performance characteristics of the alternative method and calculation of the expanded uncertainty where appropriate and check of compliance with the maximum expanded uncertainty allowed for the reference method; ? check of repeatability and lack of systematic deviation of the alternative method in the field or on a recognized test bench in comparison with the reference method for the type of matrix defined in the field of equivalence. This European Standard requires that a reference method has been defined and validated. This European Standard only considers the case of linear quantitative methods. This European Standard has been drawn up for laboratories working in air quality measurements and consequently an example taken from this sector are presented in Annex A.
Standards | Relationship |
EN 14793:2017 | Identical |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
ISO 11843-1:1997 | Capability of detection — Part 1: Terms and definitions |
EN ISO/IEC 17043:2010 | Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010) |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
ISO 11095:1996 | Linear calibration using reference materials |
ISO/IEC 17043:2010 | Conformity assessment — General requirements for proficiency testing |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
EN 15267-4:2017 | Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |