• Shopping Cart
    There are no items in your cart

BS EN 50264-3-2:2008

Current

Current

The latest, up-to-date edition.

Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-08-2008

€254.76
Excluding VAT

Introduction
1 Scope
2 Normative references
3 Definitions
4 Rated voltage
5 Marking and identification
   5.1 Marking of cable
   5.2 Core identification
   5.3 Sheath
6 Construction of cables
   6.1 General
   6.2 Conductor
   6.3 Insulation system
   6.4 Laying up of cores and fillers
   6.5 Metallic screen
   6.6 Sheath
   6.7 Construction
7 Tests
   7.1 Definitions relating to tests
   7.2 Conductor resistance
   7.3 Voltage test
   7.4 Insulation resistance
   7.5 Dielectric strength on sample
   7.6 Spark test
   7.7 Surface resistance
   7.8 Ageing test
   7.9 Hot set test
   7.10 Compatibility
   7.11 Water absorption test on sheath
   7.12 Ozone resistance
   7.13 Mineral oil resistance
   7.14 Fuel resistance
   7.15 Acid and alkali resistance
   7.16 Bending test at low temperature (cores and cables
        with OD <= 12,5 mm)
   7.17 Cold elongation test (cores and cables with
        OD > 12,5 mm)
   7.18 Impact test at low temperature
   7.19 Reaction to fire
   7.20 Reaction to fire - components
Annex A (normative) - Code designation
Bibliography

Defines requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: - 300/500 V screened or unscreened (1 mm[2], 1,5 mm[2] and 2,5 mm[2], number of cores from 2 to 40); - 0,6/1 kV screened or unscreened, (1,5 mm[2] to 50 mm[2], 2, 3 and 4 cores).

Committee
GEL/20/12
DevelopmentNote
Supersedes 05/30137088 DC. (08/2008)
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Current
Supersedes

EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings:

  • 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40);

  • 0,6/1 kV screened or unscreened, (1,5 mm2 to 50 mm2, 2, 3 and 4 cores).

NOTE Not all conductor sizes or number of cores are specified for every type.

All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.

Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.

EN 50264-3-2 should be read in conjunction with Part 1 “General requirements”.

Standards Relationship
EN 50264-3-2:2008 Identical
IEC 62485-2:2010 Identical

EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
EN 50266-2-4 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
IEC 60228:2004 Conductors of insulated cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
HD 308 S2:2001 Identification of cores in cables and flexible cords
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
EN 50266-2-5 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-5: PROCEDURES - SMALL CABLES - CATEGORY D
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.