Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-01-2015

€165.94
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Limits of supply
5 Rated values
6 Preferred values
7 Requirements
8 Tests
Annex A (informative) - Dielectric tests on sockets
Bibliography

Includes the oil-immersed single-phase connection assemblies of cables for transformers and reactors designed in accordance with EN 60076 series.

Committee
PEL/14
DevelopmentNote
Together with BS EN 50299-1, it supersedes BS EN 50299 which remains current and will be withdrawn on 13/10/2017. Supersedes 13/30281716 DC. (02/2015)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard covers the oil-immersed single-phase connection assemblies of cables for transformers and reactors designed in accordance with EN60076 series. NOTE The term \'transformer\' is used as common definition for transformer and reactor. If no separate cable connection box is used and dry-type cable terminations are directly installed into the transformer tank the requirements of this standard should be followed. The purpose of EN50299‑2 is to establish for the cable connection assemblies: electrical and mechanical requirements including interchangeability; limits of supply; tests to be carried out. It complements and amends, if necessary, the relevant standards and applies to dry-type cable terminations for power cables with extruded insulation which may be used with similar interfaces for the cable entrance in switchgear applications according to EN62271‑209 . This standard applies to oil-filled cable connection boxes of transformers with highest voltage for equipment from U m=72,5kV to 550kV, including the conductor current terminal with removable link between the transformer and the dry-type cable termination.

Standards Relationship
EN 50299-2:2014 Identical

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
HD 632 S1:1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
EN 60422:2013 Mineral insulating oils in electrical equipment - Supervision and maintenance guidance
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
IEC 60422:2013 Mineral insulating oils in electrical equipment - Supervision and maintenance guidance
EN ISO 1302:2002 Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation (ISO 1302:2002)
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
EN 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
IEC 61099:2010 Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
ISO 1302:2002 Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
EN 60296:2012 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.