Introduction
1 Scope
2 Normative references
3 Single core cables
4 Tests
Annex A (informative) Guidance on selection of cables
        for type approval
Annex B (informative) Bibliography
Tables

Gives requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm[2] to 2,5 mm[2] single core).

Committee
GEL/20/12
DevelopmentNote
Supersedes 01/206814 DC (11/2002)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-11). NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1. NOTE 3 EN 45545-1 is still under development and should be consulted. EN 50306-2 should be used in conjunction with EN 50306-1, General requirements.

Standards Relationship
DIN EN 50306-2 : 2003 Identical
IEC 61950:2007 Identical
I.S. EN 50306-2:2002 Identical
NF EN 50306-2 : 2003 Identical
EN 50306-2:2002 Identical
NEN EN 50306-2 : 2002 Identical
NBN EN 50306-2 : 2003 Identical

EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 45545-1 : 2013 COR 2013 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL
EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE