• Shopping Cart
    There are no items in your cart

BS EN 50363-1:2005

Current

Current

The latest, up-to-date edition.

Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-02-2006

€130.88
Excluding VAT

1 Scope
2 Normative references
3 Definitions
4 Properties
Tables

Defines the requirements for the cross-linked elastomeric insulating compounds.

Committee
GEL/20/17
DevelopmentNote
Supersedes BS 7655-1.1(2000) (02/2006) Supersedes 02/202787 DC. To be read in conjunction with BS EN 50363-0. (03/2006)
DocumentType
Standard
Pages
10
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396. NOTE This part of EN 50363 is to be read in conjunction with EN 50363-0. Table 1 – Types of cross-linked elastomeric insulating compound Type Maximum material operating temperature °C General application EI 2 180 Ordinary duty silicone rubber (SiR) EI 3 110 Ordinary duty EVA rubber or equivalent EI 4 60 Ordinary duty ethylene propylene rubber EI 6 90 Ordinary duty ethylene-propylene rubber or equivalent synthetic elastomer for cables requiring handling down to –40 °C EI 7 90 Ordinary duty ethylene propylene rubber or equivalent synthetic elastomer

Standards Relationship
IEC 60352-5:2008 Identical
NEN EN 50363-1 : 2006 Identical
I.S. EN 50363-1:2005 Identical
NF EN 50363-1 : 2006 Identical
EN 50363-1:2005 Identical
NBN EN 50363-1 : 2006 Identical
DIN EN 50363-1 : 2006 Identical
UNE-EN 50363-1:2006 Identical
SN EN 50363-1 : 2005 Identical

14/30295204 DC : 0 BS 7629-1 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V FIRE RESISTANT SCREENED CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE FOR FIXED INSTALLATIONS - PART 1: MULTICORE CABLES
05/30138596 DC : DRAFT SEP 2005 BS 6195 - ELECTRIC CABLES - INSULATED FLEXIBLE CABLES AND CORDS FOR COIL LEADS
BS 7629-1:2015+A1:2019 Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables
14/30295317 DC : 0 BS 4737-3.30 - INTRUDER ALARM SYSTEMS - PART 3: SPECIFICATIONS FOR OMPONENTS - SECTION 30: SPECIFICATION FOR PVC INSULATED CABLES FOR INTERCONNECTING WIRING
BS 6195:2006 Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads
BS 6007:2006 Electric cables. Single core unsheathed heat resisting cables for voltages up to and including 450/750 V, for internal wiring
08/30170023 DC : DRAFT JUNE 2008 BS 7629-1 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V FIRE RESISTANT SCREENED CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - PART 1: MULTICORE AND MULTIPAIR CABLES
DEFSTAN 61-12(PT1)/4(2008) : 2008 WIRES, CORDS AND CABLES, ELECTRICAL - PART 1: CABLES ELECTRICAL INSULATED FLEXIBLE CORDS AND FLEXIBLE CABLES
BS 7629-1:2015 Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables
BS 7629-1:2008 Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire Multicore and multipair cables

IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
HD 22.10 S2:2007 Cables of rated voltages up to and including 450/750 V and having cross-linked insulation - Part 10: EPR insulated and polyurethane sheathed flexible cables
EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 60811-3-2 : 95 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
HD 22.15 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
EN 60811-3-1 : 95 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE - TESTS FOR RESISTANCE TO CRACKING
HD 21.14 : 2003 CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 14: FLEXIBLE CABLES (CORDS), INSULATED AND SHEATHED WITH HALOGEN-FREE THERMOPLASTIC COMPOUNDS
HD 21.15 : 200S1 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 60811-3-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.