BS EN 50483-6:2009
Current
The latest, up-to-date edition.
Test requirements for low voltage aerial bundled cable accessories Environmental testing
Hardcopy , PDF
English
31-03-2009
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Marking
6 (Spare)
7 (Spare)
8 Type tests
8.1 Number of test samples and number of cycles
8.2 Requirements
8.3 Cleaning
8.4 Corrosion ageing tests
8.5 Climatic ageing test
Annex A (informative) - Salt mist and gas atmosphere
corrosion test justification
Annex B (informative) - Example of specific reaction
to obtain sulphur dioxide
Annex C (informative) - Climatic areas
Annex D (informative) - Test equipment
Bibliography
Describes a method of testing the suitability of accessories when used under normal operating conditions with low voltage aerial bundled cables complying with HD 626.
Committee |
GEL/20/11
|
DevelopmentNote |
Supersedes 05/30142739 DC. (03/2009)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 5 applies to the connections described in EN 50483-4, including branch connectors, Insulation Piercing Connectors (IPC), pre-insulated lugs (terminals) and through pre-insulated connectors (sleeves). The objective is to provide a method of testing the suitability of connectors when used under normal operating conditions with low voltage aerial bundled cables complying with HD 626. Two classes of connectors are covered by this standard: Class A: These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors will be suitable for the majority of applications. Class B: These are connectors for networks in which overloads or short-circuits are rapidly cleared by the operation of protection devices. Depending on their application, the connectors are subjected to heat cycles and short-circuit current tests. Class A: the connectors are subjected to heat cycles and short-circuit current tests. Class B: the connectors are subjected to heat cycles only. The object of this Part 5 is to define the heating cycles test methods and requirements which apply to compression through connectors, insulation piercing connectors and all other type of connections for low voltage aerial bundled cables. NOTE This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European Standard. It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately
Standards | Relationship |
EN 50483-6:2009 | Identical |
EN 50483-5:2009 | Identical |
ISO 9223:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 60068-2-9:1999 | Environmental testing - Part 2: Tests - Guidance for solar radiation testing |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
ISO 9226:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Determination of corrosion rate of standard specimens for the evaluation of corrosivity |
EN ISO 3231:1997 | Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993) |
ASTM G 85 : 2011 : REDLINE | Standard Practice for Modified Salt Spray (Fog) Testing |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
ISO 9225:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Measurement of environmental parameters affecting corrosivity of atmospheres |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
IEC 60068-2-9:1975 | Environmental testing - Part 2: Tests. Guidance for solar radiation testing |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
EN 60068-2-5:2011 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
ISO 3231:1993 | Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.