• There are no items in your cart

BS EN 50483-6:2009

Current

Current

The latest, up-to-date edition.

Test requirements for low voltage aerial bundled cable accessories Environmental testing

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-2009

€217.36
Excluding VAT

1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Marking
6 (Spare)
7 (Spare)
8 Type tests
  8.1 Number of test samples and number of cycles
  8.2 Requirements
  8.3 Cleaning
  8.4 Corrosion ageing tests
  8.5 Climatic ageing test
Annex A (informative) - Salt mist and gas atmosphere
        corrosion test justification
Annex B (informative) - Example of specific reaction
        to obtain sulphur dioxide
Annex C (informative) - Climatic areas
Annex D (informative) - Test equipment
Bibliography

Describes a method of testing the suitability of accessories when used under normal operating conditions with low voltage aerial bundled cables complying with HD 626.

Committee
GEL/20/11
DevelopmentNote
Supersedes 05/30142739 DC. (03/2009)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

EN 50483 series applies to overhead line fittings for tensioning, supporting and connecting aerial bundled cables (ABC) of rated voltage U0/U (Um): 0,6/1 (1,2) kV. This Part 5 applies to the connections described in EN 50483-4, including branch connectors, Insulation Piercing Connectors (IPC), pre-insulated lugs (terminals) and through pre-insulated connectors (sleeves). The objective is to provide a method of testing the suitability of connectors when used under normal operating conditions with low voltage aerial bundled cables complying with HD 626. Two classes of connectors are covered by this standard: Class A: These are connectors intended for electricity distribution or industrial networks in which they can be subjected to short-circuits of relatively high intensity and duration. As a consequence, Class A connectors will be suitable for the majority of applications. Class B: These are connectors for networks in which overloads or short-circuits are rapidly cleared by the operation of protection devices. Depending on their application, the connectors are subjected to heat cycles and short-circuit current tests. Class A: the connectors are subjected to heat cycles and short-circuit current tests. Class B: the connectors are subjected to heat cycles only. The object of this Part 5 is to define the heating cycles test methods and requirements which apply to compression through connectors, insulation piercing connectors and all other type of connections for low voltage aerial bundled cables. NOTE This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European Standard. It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately

Standards Relationship
EN 50483-6:2009 Identical
EN 50483-5:2009 Identical

ISO 9223:2012 Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation
ISO 4892-1:2016 Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance
IEC 60068-2-5:2010 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
EN 60068-2-9:1999 Environmental testing - Part 2: Tests - Guidance for solar radiation testing
EN ISO 4892-1:2016 Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016)
ISO 9226:2012 Corrosion of metals and alloys — Corrosivity of atmospheres — Determination of corrosion rate of standard specimens for the evaluation of corrosivity
EN ISO 3231:1997 Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993)
ASTM G 85 : 2011 : REDLINE Standard Practice for Modified Salt Spray (Fog) Testing
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
ISO 9225:2012 Corrosion of metals and alloys — Corrosivity of atmospheres — Measurement of environmental parameters affecting corrosivity of atmospheres
HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
IEC 60068-2-9:1975 Environmental testing - Part 2: Tests. Guidance for solar radiation testing
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
EN 60068-2-5:2011 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
ISO 3231:1993 Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.