BS EN 50491-4-1:2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) General functional safety requirements for products intended to be integrated in Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS)
Hardcopy , PDF
04-10-2023
English
31-05-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Requirements for functional safety
Annex A (informative) - Example of a method for
the determination of safety integrity levels
Annex B (informative) - Hazards and development
of necessary functional safety requirements
Annex C (informative) - Some examples of non safety
related HBES/BACS applications
Bibliography
Gives the requirements for functional safety for HBES/BACS products and systems, a multi-application bus system where the functions are decentralised, distributed and linked through a common communication process.
Committee |
IST/6/-/12
|
DevelopmentNote |
Supersedes BS EN 50090-2-3. (05/2012)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This European Standard sets the requirements for functional safety for HBES/BACS products and systems, a multi-application bus system where the functions are decentralised, distributed and linked through a common communication process. The requirements may also apply to the distributed functions of any equipment connected in a home or building control system if no specific functional safety standard exists for this equipment or system.
The functional safety requirements of this European Standard apply together with the relevant product standard for the device if any.
This European Standard is part of the EN 50491 series of standards.
This European Standard does not provide functional safety requirements for safety-related systems.
Standards | Relationship |
EN 50491-4-1:2012 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
EN 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements |
IEC GUIDE 110:2014 | Home control systems - Guidelines relating to safety |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 50491-3:2009 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements |
IEC TS 61000-1-2:2008 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 41003:2008 | Particular safety requirements for equipment to be connected to telecommunication networks and/or a cable distribution system |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 50491-2 : 2010 AMD 1 2015 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 2: ENVIRONMENTAL CONDITIONS |
IEC TR 61000-2-1:1990 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
EN 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.