BS EN 50525-2-83:2011
Current
The latest, up-to-date edition.
Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Multicore cables with crosslinked silicone rubber insulation
Hardcopy , PDF
English
30-09-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Heat resistant cables (180 degrees C)
Annex A (normative) - Tests for cables to EN 50525-2-83
Annex B (normative) - General data
Annex C (normative) - Requirements for compatibility test
National Annex (informative) - Origins and identification
of the particular cable types
Bibliography
Pertains to multicore cables insulated and sheathed with heat resistant crosslinked silicone rubber.
| Committee |
GEL/20/17
|
| DevelopmentNote |
Together with BS EN 50525-1, 2-11, 2-21, 2-51 & 3-21, supersedes BS 7919(2001). To be read in conjunction with BS EN 50525-1. Supersedes 08/30188826 DC. (10/2011)
|
| DocumentType |
Standard
|
| Pages |
18
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This European Standard applies to multicore cables insulated and sheathed with heat resistant crosslinked silicone rubber. Types with or without an overall textile braid, and with or without a strain-bearing element, are included.
The cables are of rated voltages U0/U 300/500 V.
The cables are intended for use within high temperature zones, either:
- in fixed installations with mechanical protection (cables to 4.1); or
- for flexible use under low mechanical stress (cables to 4.2).
The maximum conductor operating temperature for each of the cables in this standard is 180 °C.
NOTE HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN 50525-2-83 should be read in conjunction with EN 50525-1, which specifies general requirements.
| Standards | Relationship |
| IEC 60143-1:2015 | Identical |
| EN 50525-2-83:2011 | Identical |
| EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
| IEC 60228:2004 | Conductors of insulated cables |
| EN ISO 6892-1:2016 | Metallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2016) |
| ISO 6892-1:2016 | Metallic materials — Tensile testing — Part 1: Method of test at room temperature |
| EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
| EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
| IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
| IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
| EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
| IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
| EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
| HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
| EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds |
| IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
| EN 50363-2-1 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
| EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.