BS EN 54-20:2006
Current
The latest, up-to-date edition.
Fire detection and fire alarm systems Aspirating smoke detectors
Hardcopy , PDF
English
30-06-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
5.1 Compliance
5.2 Individual visual alarm indication
5.3 Connection of ancillary devices
5.4 Manufacturer's adjustments
5.5 On site adjustment of response behaviour
5.6 Response to slowly developing fires
5.7 Mechanical strength of the pipework
5.8 Hardware components and additional sensing elements
in the sampling device
5.9 Airflow monitoring
5.10 Power supply
5.11 Data
5.12 Additional requirements for software controlled
detectors
6 Tests
6.1 General
6.2 Repeatability
6.3 Reproducibility
6.4 Variation in supply parameters
6.5 Dry heat (operational)
6.6 Cold (operational)
6.7 Damp heat, steady state (operational)
6.8 Damp heat, steady state (endurance)
6.9 Sulfur dioxide (SO[2]) corrosion (endurance)
6.10 Shock (operational)
6.11 Impact (operational)
6.12 Vibration, sinusoidal (operational)
6.13 Vibration, sinusoidal (endurance)
6.14 Electromagnetic compatibility (EMC) immunity tests
6.15 Fire sensitivity
7 Classification and designation
8 Marking
Annex A (informative) - Apparatus for Response Threshold
Value (RTV) measurements
Annex B (normative) - Smoldering (pyrolysis) wood fire
(TF2)
B.1 Fuel
B.2 Hotplate
B.3 Arrangement
B.4 Heating rate
B.5 End of test condition
B.6 Test validity criteria
Annex C (normative) - Reduced smoldering pyrolysis wood
fires (TF2A and TF2B)
C.1 Fuel
C.2 Hotplate
C.3 Arrangement
C.4 Heating rate
C.5 End of test condition
C.6 Test validity criteria
Annex D (normative) - Glowing smouldering cotton fire
(TF3)
D.1 Fuel
D.2 Arrangement
D.3 Ignition
D.4 End of test condition
D.5 Test validity criteria
Annex E (normative) - Reduced glowing smoldering cotton
fire (TF3A and TF3B)
E.1 Fuel
E.2 Arrangement
E.3 Ignition
E.4 End of test condition
E.5 Test validity criteria
Annex F (normative) - Flaming plastics (polyurethane)
fire (TF4)
F.1 Fuel
F.2 Arrangement
F.3 Ignition
F.4 End of test condition
F.5 Test validity criteria
Annex G (normative) - Flaming liquid (n-heptanes) fire
(TF5)
G.1 Fuel
G.2 Arrangement
G.3 Ignition
G.4 End of test condition
G.5 Test validity criteria
Annex H (normative) - Reduced flaming liquid
(n-heptanes) fire (TF5A and TF5B)
H.1 Fuel
H.2 Arrangement
H.3 Ignition
H.4 End of test condition
H.5 Test validity criteria
Annex I (normative) - Fire test room and ventilation
system
I.1 Fire test room
I.2 Ventilation system
Annex J (informative) - Information concerning the
requirements for the response to
slowly developing fires
Annex K (informative) - Apparatus for air flow monitoring
test
K.1 General
K.2 Airflow measuring with worst-case sampling
device
K.3 Airflow monitoring test with test pipe network
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the
EU Construction Products Directive
ZA.1 Scope and relevant clauses
ZA.2 Procedures for the attestation of conformity of
aspirating smoke detectors covered by this
standard
ZA.3 CE Marking and labelling and accompanying
documentation
ZA.4 EC certificate and declaration of conformity
Bibliography
Describes the requirements, test methods and performance criteria for aspirating smoke detectors for use in fire detection and fire alarm systems installed in buildings.
| Committee |
FSH/12
|
| DevelopmentNote |
Supersedes 04/30104415 DC. (08/2006)
|
| DocumentType |
Standard
|
| Pages |
84
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NS EN 54-20 : 2006 AC 2008 | Identical |
| I.S. EN 54-20:2006 | Identical |
| NF EN 54-20 : 2006 | Identical |
| DIN EN 54-20:2009-02 | Identical |
| NBN EN 54-20 : 2006 COR 2008 | Identical |
| NEN EN 54-20 : 2006 C1 2009 | Identical |
| EN 54-20:2006 | Identical |
| EN 54-20:2006 | Equivalent |
| I.S. EN 54-20:2006 | Equivalent |
| UNE-EN 54-20:2007 | Identical |
| BS 5839-1(2002) : 2002 | FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
| BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
| 12/30260278 DC : 0 | BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
| 12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
| PD ISO/TR 19814:2017 | Information and documentation. Collections management for archives and libraries |
| BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
| ISO/TR 19814:2017 | Information and documentation — Collections management for archives and libraries |
| BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
| PD 5454:2012 | Guide for the storage and exhibition of archival materials |
| 07/30171700 DC : DRAFT OCT 2007 | BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
| EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
| EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
| EN 61386-1:2008 | Conduit systems for cable management - Part 1: General requirements |
| EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
| IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| IEC 60068-2-2a:1976 | Supplement A - Basic environmental testing procedures - Part 2: Tests - Tests B: Dry heat |
| ISO 9001:2015 | Quality management systems — Requirements |
| IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
| EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
| EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
| IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| IEC 61386-1:2008+AMD1:2017 CSV | Conduit systems for cable management - Part 1: General requirements |
| IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
| EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.