BS EN 60068-2-27:2009
Current
The latest, up-to-date edition.
Environmental testing Tests. Test Ea and guidance. Shock
Hardcopy , PDF
English
31-07-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Description of test apparatus
4.1 Required characteristics
4.2 Measuring system
4.3 Mounting
5 Severities
6 Preconditioning
7 Initial measurements and functional performance test
8 Testing
9 Recovery
10 Final measurements
11 Information to be given in the relevant specification
12 Information to be given in the test report
Annex A (normative) - Selection and application of pulse
shapes - Guidance
Annex B (informative) - Shock response spectra and other
characteristics of pulse shapes
Annex C (informative) - Comparison between impact tests
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes a standard procedure for determining the ability of a specimen to withstand specified severities of non-repetitive or repetitive shocks.
Committee |
GEL/104
|
DevelopmentNote |
Renumbers and supersedes BS 2011-2.1EA(1988) Supersedes 83/27946 DC & BS 2011-2.1EA(1977). 1993 version incorporates amendment 7814 to BS 2011-2.1EA(1988). (09/2005) Supersedes BS EN 60068-2-29 & 05/30138371 DC. (07/2009)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60068-2-27:2008 provides a standard procedure for determining the ability of a specimen to withstand specified severities of non-repetitive or repetitive shocks. The purpose of this test is to reveal mechanical weakness and/or degradation in specified performances, or accumulated damage or degradation caused by shocks. In conjunction with the relevant specification, this may be used in some cases to determine the structural integrity of specimens or as a means of quality control. This test is primarily intended for unpackaged specimens and for items in their transport case when the latter may be considered to be part of the specimen. If an item is to be tested unpackaged, it is referred to as a test specimen. However, if the item is packaged, then the item itself is referred to as a product and the item and its packaging together are referred to as a test specimen. When used in conjunction with IEC 60068-2-47, this standard may be used for testing packaged products. This possibility was included in the 2005 version of IEC 60068-2-47 for the first time. This standard is written in terms of prescribed pulse shapes. Guidance for the selection and application of these pulses is given in Annex A and the characteristics of the different pulse shapes are discussed in Annex B. Wherever possible, the test severity and the shape of the shock pulse applied to the specimen should be such as to reproduce the effects of the actual transport or operational environment to which the specimen will be subjected, or to satisfy the design requirements if the object of the test is to assess structural integrity (see Clauses A.2 and A.4). For the purposes of this test, the specimen is always mounted to the fixture or the table of the shock testing machine during testing. The major changes with regard to the previous edition concern:
- the merging of IEC 60068-2-29 into this edition of IEC 60068-2-27; Part 2-29 will be withdrawn as soon as this edition is published;
- the introduction of soft packaged specimens as defined in the IEC ad hoc working group document agreed in Stockholm:2000.
It has the status of a horizontal standard in accordance with IEC Guide 104.
Standards | Relationship |
I.S. EN 60068-2-27:2009 | Identical |
EN 60068-2-27:2009 | Identical |
DIN EN 60068-2-27 : 1995 | Identical |
IEC 60068-2-27:2008 | Identical |
SN EN 60068-2-27 : 1993 | Identical |
UNE-EN 60068-2-27:2011 | Identical |
14/30277275 DC : 0 | BS 5446-3 - FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 3: SPECIFICATION FOR FIRE AND CARBON MONOXIDE ALARM SYSTEMS FOR DEAF AND HARD OF HEARING PEOPLE |
BS PAS 40(2002) : 2002 | BANKNOTE THEFT DETERRENT SYSTEMS USING DYE OR SMOKE-DYE |
BS EN 61096:1993 | Methods of measuring the characteristics of reproducing equipment for digital audio compact discs |
BS EN 119000:1997 | Harmonized system of quality assessment for electronic components. Generic specification: dry and mercury wetted reed contact units |
DEFSTAN 61-021 SUPP01/5(2017) : 2017 | GENERAL SPECIFICATION FOR BATTERIES - SUPPLEMENT 01: SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY, 1.5V, NSN 6135-99-195-6708 LR6, NSN 6135-99-117-3212 LR14, NSN 6135-99-109-9428 LR20 |
DEFSTAN 61-021 SUPP49/4(2021):2021 | General Specification for Batteries<br>Supplement: 049 : Lithium Thionyl Chloride Battery 14V 160AH (Nominal) NSN 6135-99-617-2805<br> |
DEFSTAN 44-2(PT2)/5(2004) : 2004 | DESICCANT CONTAINERS, DEHUMIDIFIER - PART 2: GENERAL AND TEST REQUIREMENTS |
DEFSTAN 61-021 SUPP01/6(2018) : 2018 | GENERAL SPECIFICATION FOR BATTERIES - SUPPLEMENT 01: SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY, 1.5V, NSN 6135-99-195-6708 LR6, NSN 6135-99-117-3212 LR14, NSN 6135-99-109-9428 LR20 |
DEFSTAN 00-035(PT5)/5(2018) : 2018 | ENVIRONMENTAL HANDBOOK FOR DEFENCE MATERIEL - PART 5: MECHANICAL ENVIRONMENTS |
DEFSTAN 81-41(PT3)/6(2014) : 2014 | PACKAGING OF DEFENCE MATERIEL - PART 3: ENVIRONMENTAL TESTING |
BS 7951:2000 | Electricity meters. Alternating-current single-phase static watt-hour telemeters of accuracy class 1 or 2 |
BS PAS 019(1997) : 1997 | |
BS EN 129000:1996 | Harmonized system of quality assessment for electronic components. Generic specification. Fixed RF wound inductors |
BS EN 147000:1995 | Harmonized system of quality assessment for electronic components. Generic specification. Sockets for use with electrical relays of assessed quality |
BS EN 137000:1996 | Harmonized system of quality assessment for electronic components. Generic specification: Fixed aluminium electrolytic a.c. capacitors with non-solid electrolyte for use with motors |
BS 9450:1998 | Specification for integrated electronic circuits and micro-assemblies of assessed quality (capability approval procedures). Generic data and methods of test |
BS EN 120000:1996 | Harmonized system of quality assessment for electronic components. General specification: semiconductor optoelectronic and liquid crystal devices |
BS EN 116000-3:1996 | Harmonized system of quality assessment for electronic components. Generic specification: electromechanical all-or-nothing relays Test and measurement procedures |
BS EN 122160:1996 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SSMA |
BS EN 60721-1:1996 | Classification of environmental conditions Environmental parameters and their severities |
BS EN 134000:1995 | Harmonized system of quality assessment for electronic components. Generic specification: variable capacitors. (Qualification approval and capability approval) |
BS EN 61268:1996 | Alternating current static var-hour meters for reactive energy (classes 2 and 3) |
BS EN 122110:1994 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SMA |
BS EN 122140:1994 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SMC |
BS 5446-3:2015 | Detection and alarm devices for dwellings Specification for fire alarm and carbon monoxide alarm systems for deaf and hard of hearing people |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 60721-3-1:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
IEC 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 60068-2-55:2013 | Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
ISO 8568:2007 | Mechanical shock Testing machines Characteristics and performance |
IEC 60068-2-55:2013 | Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce |
EN 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
IEC 60721-3-1:1997 | Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.