BS EN 60068-2-64:1995
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Environmental testing. Test methods Test Fh. Vibration, broad-band random (digital control) and guidance
Hardcopy , PDF
13-12-2019
English
25-01-2006
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for test apparatus
4.1 General
4.2 Basic motion
4.3 Cross-axis motion
4.4 Mounting
4.5 Measuring systems
4.6 Vibration tolerances
4.7 Control strategy
4.8 Vibration response investigation
5 Severities
5.1 Test frequency range
5.2 RMS value of acceleration
5.3 Shape of acceleration spectral density curve
5.4 Test duration
6 Preconditioning
7 Initial measurements and functional performance test
8 Testing
8.1 General
8.2 Initial vibration response investigation
8.3 Low-level excitation for equalization
prior to testing
8.4 Random testing
8.5 Final vibration response investigation
9 Recovery
10 Final measurements and functional performance
11 Information to be given in the relevant specification
12 Information to be given in the test report
Annex A (informative) - Standardized test spectra
Annex B (informative) - Guidance
Bibliography
Annex ZA (normative) - Normative references to
international publications with
their corresponding European
publications
Describes the adequacy of specimens to resist dynamic loads without unacceptable degradation of its functional and/or structural integrity when subjected to the specified random vibration test requirements.
Committee |
GEL/104
|
DevelopmentNote |
To be read in conjunction with BS EN 60068-1. Supersedes BS 2011-2.1FD(1973), BS 2011-2.1FDB(1973), BS 2011-2.1FDC(1973) and 90/33354 DC. (02/2004) Supersedes BS 2011-2.1FDA(1973) (03/2006) Supersedes 05/30140060 DC. (02/2009)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 60068-2-64:1993 | Identical |
EN 60068-2-64:1994 | Identical |
I.S. EN 60068-2-64:2008 | Identical |
SN EN 60068-2-64 : 1994 | Identical |
IEC 60068-2-64:2008 | Identical |
UNE-EN 60068-2-64:2009 | Identical |
DIN EN 60068-2-64 : 1995 | Identical |
EN 60068-2-64:2008 | Identical |
BS PAS 40(2002) : 2002 | BANKNOTE THEFT DETERRENT SYSTEMS USING DYE OR SMOKE-DYE |
BS 5760-13.5:1996 | Reliability of systems, equipment and components. Guide to reliability test conditions for consumer equipment Ground mobile equipment. Low degree of simulation |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 300 019-2-3 : 2.4.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-3: SPECIFICATION OF ENVIRONMENTAL TESTS; STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
IEC 60068-5-2:1990 | Environmental testing - Part 5-2: Guide to drafting of test methods - Terms and definitions |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
EN 300 019-2-7 : 3.0.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-7: SPECIFICATION OF ENVIRONMENTAL TESTS; PORTABLE AND NON-STATIONARY USE |
EN 60068-5-2:1999 | Environmental testing - Part 5: Guide to drafting of test methods - Terms and definitions |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.