BS EN 60143-1:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Series capacitors for power systems General
Hardcopy , PDF
09-01-2024
English
31-10-2015
Committee |
W/-
|
DevelopmentNote |
Renumbers and supersedes BS EN 60143. Supersedes 91/29696 DC. 1993 version incorporates amendment 8725 to BS EN 60143. (09/2005) Supersedes 01/203455 DC (10/2005) Supersedes 14/30310457 DC. (10/2015)
|
DocumentType |
Standard
|
Pages |
70
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This part of IEC60143 applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15Hz to 60Hz. The primary focus of this standard is on transmission application. The series capacitor units and banks are usually intended for high-voltage power systems. This standard is applicable to the complete voltage range. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors, even if connected in series with a circuit, are excluded from this standard: capacitors for inductive heat-generating plants ( IEC60110‑1 ); capacitors for motor applications and the like ( IEC60252(all parts)); capacitors to be used in power electronics circuits ( IEC61071 ); capacitors for discharge lamps ( IEC61048 and IEC61049 ). For standard types of accessories such as insulators, switches, instrument transformers, external fuses, etc. see the pertinent IEC standard. NOTE1 Additional requirements for capacitors to be protected by internal fuses, as well as the requirements for internal fuses, are found in IEC60143‑3 . See also AnnexC. NOTE2 Additional requirements for capacitors to be protected by external fuses, as well as the requirements for external fuses, are found in AnnexA and AnnexC. NOTE3 A separate standard for series capacitor accessories (spark-gaps, varistors, discharge reactors, current-limiting damping reactors, damping resistors, circuit-breakers, etc.), IEC60143‑2, has been revised and was completed in 2012. A separate standard for internal fuses for series capacitors, IEC60143‑3 has been revised and was completed in 2013. NOTE4 Some information regarding fuseless capacitor units and fuseless capacitor banks is found in AnnexC. The object of this standard is: to formulate uniform rules regarding performance, testing and rating; to formulate specific safety rules; to serve as a guide for installation and operation.
Standards | Relationship |
EN 50525-2-83:2011 | Identical |
EN 60143-1:2015 | Identical |
IEC 60143-1:2015 | Identical |
EN 60143-1:2015/AC:2017-05 | Identical |
UNE-EN 60143-1:2004 | Identical |
NBN EN 60143-1 : 2005 | Identical |
DIN EN 60143-1 : 2016 | Identical |
I.S. EN 60143-1:2015 | Identical |
SN EN 60143-1 : 1993 | Identical |
NF EN 60143-1 : 2015 | Identical |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60143-2:2012 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
EN 60143-3:2015 | Series capacitors for power systems - Part 3: Internal fuses |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
IEC 60909-0:2016 | Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents |
EN 60252-1 : 2011 AMD 1 2013 | AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION (IEC 60252-1:2010/A1:2013) |
IEC 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC TR 60996:1989 | Method for verifying accuracy of tan delta measurements applicable to capacitors |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
EN 61049:1993 | Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements |
EN 61071:2007 | Capacitors for power electronics |
EN 60143-2:2013 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 60721-2-6:1990 | Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
EN 60909-0:2016 | Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60252-1:2010+AMD1:2013 CSV | AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60050-436:1990 | International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
EN 60110-1:1998 | Power capacitors for induction heating installations - Part 1: General |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
EN 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
IEC 60143-3:2015 | Series capacitors for power systems - Part 3: Internal fuses |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC 60143-4:2010 | Series capacitors for power systems - Part 4: Thyristor controlled series capacitors |
EN 60143-4 : 2010 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
IEC 60110-1:1998 | Power capacitors for induction heating installations - Part 1: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-