1 Scope
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Thermal ageing methods
8.1 Ageing in an air oven
8.2 Ageing in an air bomb
8.3 Ageing in an oxygen bomb
8.4 Methods of measuring air flow in ovens
FIGURES
Appendix A - Corresponding clauses and sub-clauses in
IEC Publications 538 and 540 and IEC
Publication 811
Annex ZA (normative) Normative references to
international publications with their
corresponding European publications
Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables for power distribution and telecommunications including cables used on ships.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes 97/203530 DC and BS 6469-1.2(1992) (05/2002) Also available as part of BS KIT 154 (12/2004) Reviewed and confirmed by BSI, June, 2005. (05/2005) Also numbered as IEC 60811-1-2 (11/2005)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 60811-1-2:1995/A2:2000 | Identical |
DIN EN 60811-1-2 : 2001 | Identical |
SN EN 60811-1-2 : 1995 AMD 2 2000 | Identical |
I.S. EN 60811-1-2:1997 | Identical |
UNE-EN 60811-1-2:1996 | Identical |
BS 4553-1:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having PVC insulation |
BS 7870-3.50:2005 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603) |
BS 7870-5:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
07/30143023 DC : DRAFT MAR 2007 | BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
BS 7870-6.3:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - Cables with thermosetting insulation and non-halogenated sheath |
11/30214073 DC : 0 | BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
BS 4553-3:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire |
BS 7870-3.12:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7870-8.5:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath |
BS 7870-6.2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - XLPE or HEPR insulated and PVC sheathed cables |
BS 7870-4.11:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 33 kV lead sheathed cables - Single core 33 kV lead sheathed cables |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
11/30214068 DC : 0 | BS 7870-3.40 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.40: XLPE INSULATED, COPPER WIRE WAVEFORM CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS |
BS 7870-4.10(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-3.21:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated split concentric cables with copper or aluminium conductors |
BS 7846:2000 | Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire |
BS 7870-4.11(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-4.20(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7846:2009 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7870-4.10:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 11 kV and 33 kV cables - Single core 11 kV and 33 kV cables |
11/30214061 DC : 0 | BS 7870-3.12 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.12: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
11/30219798 DC : 0 | BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION |
12/30248753 DC : 0 | BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING |
BS 7870-3.40:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
BS 7655-10.1(1997) : 1997 | SPECIFICATION FOR INSULATING AND SHEATHING MATERIALS FOR CABLES - POLYETHYLENE SHEATHING COMPOUNDS - THERMOPLASTIC MEDIUM DENSITY POLYETHYLENE (MDPE) SHEATHING COMPOUND |
06/30143016 DC : DRAFT SEP 2006 | BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV |
BS 7870-3.11:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
BS 6195:2006 | Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads |
BS 6622:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods |
BS 6500:2000 | Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments |
BS 6883:1999 | Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods |
BS 7870-3.12:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 6724(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 6622:1999 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV |
BS 7889:1997 | Electric cables. Thermosetting insulated, unarmoured cables for a voltage of 600/1000 V |
BS 7655-0:1997 | Specification for insulating and sheathing materials for cables General introduction |
BS 7835:2000 | Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV having low emission of smoke and corrosive gases when affected by fire |
BS 5467(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V |
BS 7211:1998 | Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire |
BS 6622:1991 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V |
BS 7870-3.11:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
BS 7835:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods |
BS 7655-0:2006 | Specification for insulating and sheathing materials for cables General introduction |
BS 7870-3.21:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors |
BS 7870-5:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
BS 7870-3.40:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors |
BS 7870-3.50:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7912:2001 | Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 4553-2:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation |
11/30214071 DC : 0 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
05/30126924 DC : DRAFT MAY 2005 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7846:1996 | Specification for 600/1000 V armoured fire-resistant electric cables having low emission of smoke and corrosive gases when affected by fire |
BS 7870-7.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring |
BS 7870-4.13:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 33 kV copper wire/foil sheath cables - Section 4.13: Single core 33 kV copper wire/foil sheath cables |
11/30214077 DC : 0 | BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES |
11/30214065 DC : 0 | BS 7870-3.22 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.22: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7870-8.6:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors |
BS 6346:1997 | Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V |
BS 7870-2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
BS 7870-4.12:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 11 kV copper foil sheath cables - Section 4.12: single core 11 kV copper foil sheath cables |
11/30214075 DC : 0 | BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES |
BS 7919:2001 | Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments |
11/30214057 DC : 0 | BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST |
BS 7917:1999 | Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods |
BS 7870-7.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring |
11/30215743 DC : 0 | BS 7870-3.21 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.21: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
BS 7870-6.1:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations PVC insulated and PVC sheathed cables |
09/30199575 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
BS 7870-3.20:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated split concentric cables with copper or aluminium conductors |
BS 7870-4.20:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Three-core 11 kV cables - Three core 11 kV cables |
BS 7870-3.4:1996 | |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
11/30214059 DC : 0 | BS 7870-3.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.11: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
BS 7870-3.22:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7870-3.10:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
BS 6004:2000 | Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring |
IEC 60538:1976 | Electric cables, wires and cords: Methods of test for polyethylene insulation and sheath |
EN 60811-3-2 : 95 AMD 2 2004 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST |
HD 505.1.1 : 200S3 | COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES |
IEC 60538A:1980 | First supplement |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
IEC 60811-3-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.