BS EN 61095:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Specification for electromechanical contactors for household and similar purposes
Hardcopy , PDF
26-10-2018
English
25-01-2002
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms
3.2 Switching devices
3.3 Parts of switching devices
3.4 Operation of switching devices
3.5 Characteristic quantities
4 Classification
5 Characteristics of contactors
5.1 Summary of characteristics
5.2 Type of contactor
5.2.1 Number of poles
5.2.2 Method of control
5.3 Rated and limiting values for main circuits
5.3.1 General
5.3.2 Rated voltages
5.3.3 Currents or powers
5.3.4 Rated frequency
5.3.5 Rated duties
5.3.6 Normal load and overload characteristics
5.3.7 Rated conditional short-circuit current
6 Product information
6.1 Nature of information
6.1.1 Identification
6.1.2 Characteristics, basic rated values and
utilization
6.2 Marking
6.3 Instructions for installation, operation and
maintenance
7 Normal service, mounting and transport conditions
7.1 Normal service conditions
7.1.1 Ambient air temperature
7.1.2 Altitude
7.1.3 Atmospheric conditions
7.1.4 Normal electromagnetic environmental
conditions
7.2 Conditions during transport and storage
7.3 Mounting
8 Constructional and performance requirements
8.1 Constructional requirements
8.1.1 General
8.1.2 Materials
8.1.3 Strength of screws or nuts other than
those on terminals which are intended to
be operated during installation or
maintenance
8.1.4 Vacant
8.1.5 Actuator
8.1.6 Indication of the OFF and ON positions
8.1.7 Terminals
8.1.8 Additional requirements for contactors
provided with a neutral pole
8.1.9 Provisions for earthing
8.1.10 Enclosures
8.1.11 Degrees of protection of enclosed contactors
8.1.12 Resistance to impact
8.1.13 Durability of markings
8.2 Performance requirements
8.2.1 Operating conditions
8.2.2 Temperature-rise
8.2.3 Dielectric properties
8.2.4 Normal load and overload performance
requirements
8.2.5 Co-ordination with short-circuit protective
devices
8.3 Electromagnetic compatibility
8.3.1 Immunity
8.3.2 Emission
9 Tests
9.1 Types of test
9.1.1 General
9.1.2 Type tests
9.1.3 Routine tests
9.1.4 Sampling tests for clearance verification
9.2 Compliance with constructional requirements
9.2.1 General
9.2.2 Materials
9.2.3 Test on screws or nuts other than those
on terminals which are intended to be
operated during installation or maintenance
9.2.4 Verification of the degrees of protection of
enclosed contactors
9.2.5 Mechanical properties of terminals
9.2.6 Test of resistance to impact
9.2.7 Test of durability of marking
9.3 Compliance with performance requirements
9.3.1 Test sequences
9.3.2 General test conditions
9.3.3 Performance under no load, normal load
and overload conditions
9.3.4 Performance under short-circuit conditions
9.3.5 Overload current withstand capability
9.3.6 Routine tests
Annex A (normative) - Terminal marking and distinctive
number
Annex B (normative) - Test sequences and number of
samples
Annex C (normative) - Description of a method for
adjusting the load circuit
Annex D (normative) - Determination of short-circuit
power-factor
Annex E (normative) - Measurement of creepage
distances and clearances
Annex F (normative) - Correlation between the nominal
voltage of the supply system and the rated impulse
withstand voltage of a contactor
Annex G (normative) - Hot wire ignition test
Annex H (normative) - Degrees of protection of enclosed
contactor
Annex I (normative) - Requirements and tests for equipment
with protective separation
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Defines the specific utilization category, conditions, requirements, tests and methods of test, for electromechanical air break contactors with main contacts intended for connection to circuits of 440 V a.c. maximum rated voltage.
Committee |
PEL/17
|
DevelopmentNote |
Supersedes 89/30585 DC & 95/210360 DC. (02/2002) Supersedes 06/30146995 DC. (06/2009)
|
DocumentType |
Standard
|
Pages |
126
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 61095:2009 | Identical |
NF EN 61095 : 2009 | Identical |
EN 61095:2009 | Identical |
NBN EN 61095 : 2009 | Identical |
I.S. EN 61095:2009 | Identical |
SN EN 61095 : 1993 AMD 1 2000 | Identical |
DIN EN 61095 : 2009 | Identical |
UNE-EN 61095:2010 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60028:1925 | International standard of resistance for copper |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
EN 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
ISO 2039-2:1987 | Plastics — Determination of hardness — Part 2: Rockwell hardness |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN ISO 2039-2:1999 | Plastics - Determination of hardness - Part 2: Rockwell hardness (ISO 2039-2:1987) |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.