BS EN 61811-55:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electromechanical non-specified time all-or-nothing relays of assessed quality Blank detail specification. Electromechanical all-or-nothing telecom relays of assessed quality. Two change-over contacts, 11 mm x 7,5 mm (max.) base
Hardcopy , PDF
30-04-2015
English
30-08-2002
1 General
1.1 Scope
1.2 Normative references
1.3 Front page of detail specification
2 Characteristic values of the relay
2.1 General data
2.2 Construction of IECQ type designation (ordering
information)
2.3 Coil data
2.4 Contact data
2.5 Mounting
2.6 Environmental data
2.7 Package of relays for automatic handling (if applicable)
3 Qualification approval procedures
4 Quality conformance inspection
4.1 Formation of inspection lots
4.2 Intervals between tests
5 Marking and documentation
5.1 Marking of the relay
5.2 Marking of the package
5.3 Documentation
6 Annexes
7 Tests
7.1 Standard conditions for testing
7.2 Mounting of test specimens during the test
7.3 General conditions for testing
8 Ordering information
9 Relay reliability - Failure rate data (optional)
Annex ZA (normative) Normative references international
publications with their corresponding European
publications
Applicable to electromechanical all-or-nothing telecom relays of accessed quality. Relays according to this are provided for the operation in telecommunication applications. Along with this, they are also suitable for particular industrial and other applications.
Committee |
EPL/94
|
DevelopmentNote |
Supersedes 00/203641 DC (09/2002)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 61811-55:2002 Is a blank detail specification applicable to electromechanical all-or-nothing telecom relays of assessed quality. Selects the appropriate methods of test to be used in detail specifications and contains basic test schedules to be used in the preparation of such specifications. The contents of the corrigendum of June 2002 have been included in this copy.
Standards | Relationship |
IEC 61811-55:2002 | Identical |
NBN EN 61811-55 : 2002 | Identical |
I.S. EN 61811-55:2002 | Identical |
NF EN 61811-55 : 2003 | Identical |
DIN EN 61811-55:2003-02 | Identical |
EN 61811-55:2002 | Identical |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 61811-50:2002 | Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
BS QC 001002-2:1997 | Documentation, including a new clause on regulations for technology approval schedulesRules of procedure of the IEC quality assessment system for electronic components (IECQ) |
CECC 00802 : 1994 | GUIDANCE DOCUMENT: CECC STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING (SMDs) OF ASSESSED QUALITY |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 61810-7:2006 | Electromechanical elementary relays - Part 7: Test and measurement procedures |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
IEC 60255-14:1981 | Electrical relays. Part 14: Endurance tests for electrical relay contacts - Preferred values for contact loads |
IEC 61811-50:2002 | Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality |
BS QC 001002-3:1997 | Rules of procedure of the IEC quality assessment system for electronic components (IECQ) Approval procedures, including a new clause on technology approval |
IEC 61811-1:2015 | Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification |
EN 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
EN 60695-2-2:1994/A1:1995 | FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST |
EN 61811-1:2015 | Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.