BS EN ISO 9614-3:2009
Current
The latest, up-to-date edition.
Acoustics. Determination of sound power levels of noise sources using sound intensity Precision method for measurement by scanning
Hardcopy , PDF
English
30-04-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Acoustic environment
6 Instrumentation
7 Installation and operation of the source
8 Measurement of normal sound intensity component levels
9 Determination of sound power level
10 Information to be recorded
Annex A (informative) - List of symbols used in this
part of ISO 9614
Annex B (normative) - Calculation of field indicators
Annex C (normative) - Procedure for achieving the desired
accuracy
Annex D (informative) - Effects of airflow on measurement
of sound intensity
Annex E (informative) - Effect of sound absorption within
the measurement surface
Annex F (informative) - Measurement surface and scanning
procedure
Annex G (informative) - Procedure for obtaining time-averaged
intensities and squared pressures from a sequence of
short-time averaged intensities and squared pressures
Annex H (informative) - Normalization of sound power level
Annex I (informative) - Field indicators used in
ISO 9614-1, -2 and -3
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 98/37/EC
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 2006/42/EC
Describes a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined.
Committee |
EH/1/4
|
DevelopmentNote |
Supersedes 00/562493 DC (12/2002)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
1.1 This part of ISO 9614 specifies a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined.
Surface integration of the intensity component normal to the measurement surface is approximated by subdividing the measurement surface into contiguous partial surfaces, and scanning the intensity probe over each partial surface along a continuous path which covers the extent of the partial surface. The measurement instrument determines the averaged normal intensity component and averaged squared sound pressure over the duration of each scan. The scanning operation can be performed either manually or by means of a mechanical system.
The octave band or band-limited weighted sound power level is calculated from the measured one-third-octaveband values. The method is applicable to any source for which a physically stationary measurement surface can be defined, and on which the sound generated by the source under test and by other significant extraneous sources are stationary in time. The source is defined by the choice of measurement surface. The method is applicable in specific test environments fulfilling all relevant requirements of this part of ISO 9614.
This part of ISO 9614 specifies certain ancillary procedures, described in annex C, to be followed in conjunction with the sound power determination. The results are used to indicate the quality of the determination, and hence the grade of accuracy. If the quality of the determination does not meet the requirements of this part of ISO 9614, the test procedure shall be modified in the manner indicated.
This part of ISO 9614 is not applicable to any frequency band in which the sound power of the source is found to be negative on measurement.
Standards | Relationship |
NBN EN ISO 9614-3 : 2009 | Identical |
DIN EN ISO 9614-3:2009-11 | Identical |
NEN EN ISO 9614-3 : 2009 | Identical |
NS EN ISO 9614-3 : 2009 | Identical |
SN EN ISO 9614-3:2010 | Identical |
NF EN ISO 9614-3 : 2009 | Identical |
ISO 9614-3:2002 | Identical |
UNI EN ISO 9614-3 : 2009 | Identical |
EN ISO 9614-3:2009 | Identical |
I.S. EN ISO 9614-3:2009 | Identical |
UNE-EN ISO 9614-3:2010 | Identical |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
ISO 12001:1996 | Acoustics — Noise emitted by machinery and equipment — Rules for the drafting and presentation of a noise test code |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
ISO 3743-2:1994 | Acoustics Determination of sound power levels of noise sources using sound pressure Engineering methods for small, movable sources in reverberant fields Part 2: Methods for special reverberation test rooms |
ISO 7574-4:1985 | Acoustics — Statistical methods for determining and verifying stated noise emission values of machinery and equipment — Part 4: Methods for stated values for batches of machines |
ISO 9614-1:1993 | Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 1: Measurement at discrete points |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
IEC 61043:1993 | Electroacoustics - Instruments for the measurement of sound intensity - Measurements with pairs of pressure sensing microphones |
ISO 3747:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering/survey methods for use in situ in a reverberant environment |
ISO 3740:2000 | Acoustics Determination of sound power levels of noise sources Guidelines for the use of basic standards |
ISO 9614-2:1996 | Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 2: Measurement by scanning |
ISO 7574-1:1985 | Acoustics — Statistical methods for determining and verifying stated noise emission values of machinery and equipment — Part 1: General considerations and definitions |
ISO 3746:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane |
ISO/TR 7849:1987 | Acoustics Estimation of airborne noise emitted by machinery using vibration measurement |
ISO 3741:2010 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for reverberation test rooms |
ISO 3745:2012 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms |
1998/37/EC : 1998 | DIRECTIVE 98/37/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 22 JUNE 1998 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO MACHINERY |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 3743-1:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for small movable sources in reverberant fields Part 1: Comparison method for a hard-walled test room |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.