BS EN ISO 9614-3:2009
Current
The latest, up-to-date edition.
Acoustics. Determination of sound power levels of noise sources using sound intensity Precision method for measurement by scanning
Hardcopy , PDF
English
30-04-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Acoustic environment
6 Instrumentation
7 Installation and operation of the source
8 Measurement of normal sound intensity component levels
9 Determination of sound power level
10 Information to be recorded
Annex A (informative) - List of symbols used in this
part of ISO 9614
Annex B (normative) - Calculation of field indicators
Annex C (normative) - Procedure for achieving the desired
accuracy
Annex D (informative) - Effects of airflow on measurement
of sound intensity
Annex E (informative) - Effect of sound absorption within
the measurement surface
Annex F (informative) - Measurement surface and scanning
procedure
Annex G (informative) - Procedure for obtaining time-averaged
intensities and squared pressures from a sequence of
short-time averaged intensities and squared pressures
Annex H (informative) - Normalization of sound power level
Annex I (informative) - Field indicators used in
ISO 9614-1, -2 and -3
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 98/37/EC
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 2006/42/EC
Describes a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined.
| Committee |
EH/1/4
|
| DevelopmentNote |
Supersedes 00/562493 DC (12/2002)
|
| DocumentType |
Standard
|
| Pages |
48
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
1.1 This part of ISO 9614 specifies a method for measuring the component of sound intensity normal to a measurement surface which is chosen so as to enclose the sound source(s) of which the sound power level is to be determined.
Surface integration of the intensity component normal to the measurement surface is approximated by subdividing the measurement surface into contiguous partial surfaces, and scanning the intensity probe over each partial surface along a continuous path which covers the extent of the partial surface. The measurement instrument determines the averaged normal intensity component and averaged squared sound pressure over the duration of each scan. The scanning operation can be performed either manually or by means of a mechanical system.
The octave band or band-limited weighted sound power level is calculated from the measured one-third-octaveband values. The method is applicable to any source for which a physically stationary measurement surface can be defined, and on which the sound generated by the source under test and by other significant extraneous sources are stationary in time. The source is defined by the choice of measurement surface. The method is applicable in specific test environments fulfilling all relevant requirements of this part of ISO 9614.
This part of ISO 9614 specifies certain ancillary procedures, described in annex C, to be followed in conjunction with the sound power determination. The results are used to indicate the quality of the determination, and hence the grade of accuracy. If the quality of the determination does not meet the requirements of this part of ISO 9614, the test procedure shall be modified in the manner indicated.
This part of ISO 9614 is not applicable to any frequency band in which the sound power of the source is found to be negative on measurement.