BS IEC 62855:2016
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Nuclear power plants. Electrical power systems. Electrical power systems analysis
Hardcopy
03-08-2021
English
30-09-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Electrical power system analyses
6 Off-site power transient stability analyses
7 AC on-site power system analyses
8 DC system and uninterruptible AC system
analyses
9 Miscellaneous analyses
Annex A (informative) - Establishment of design
bases for nuclear power plant electrical power
systems
Annex B (informative) - Guidelines for analytical
studies
Annex C (informative) - Verification of design bases
and equipment specification
Annex D (informative) - Example of plant specific
acceptance criteria
Bibliography
Gives the electrotechnical engineering guidelines for analysis of AC and DC electrical power systems in nuclear power plants (NPPs) in order to demonstrate that the power sources and the distribution systems have the capability for safe operation and shut down of the NPP, bringing it to a controlled state after an anticipated operational occurrence or accident conditions and finally reaching a safe state.
Committee |
NCE/8
|
DevelopmentNote |
Supersedes 15/30309550 DC. (09/2016)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
IEC 62855:2016 provides the electrotechnical engineering guidelines for analysis of AC and DC electrical power systems in nuclear power plants (NPPs) in order to demonstrate that the power sources and the distribution systems have the capability for safe operation and shut down of the NPP, bringing it to a controlled state after an anticipated operational occurrence or accident conditions and finally reaching a safe state. This standard is intended to be used:
- for verification of the design of new nuclear power plants;
- for demonstrating the adequacy and impact of major modifications of electrical power systems in operating nuclear power plants;
- and where there is a requirement to assess and establish operating limits and constraints for existing plants.
Standards | Relationship |
IEC 62855:2016 | Identical |
IEC 60038:2009 | IEC standard voltages |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
ISO/IEC 27001:2013 | Information technology — Security techniques — Information security management systems — Requirements |
IEC 62342:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Management of ageing |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
IEC 62340:2007 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for coping with common cause failure (CCF) |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
ISO/IEC 27002:2013 | Information technology Security techniques Code of practice for information security controls |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 60964:2009 | Nuclear power plants - Control rooms - Design |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 62566:2012 | Nuclear power plants - Instrumentation and control important to safety - Development of HDL-programmed integrated circuits for systems performing category A functions |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.