• Shopping Cart
    There are no items in your cart

CEI 20-56 : 2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO

Available format(s)

Hardcopy , PDF

Language(s)

Italian

Published date

01-09-2010

Superseded date

21-12-2023

Superseded by

CEI HD 620 S3:2023

This Standard applies to cables with extruded insulation and for rated voltages Uo/U(Um) from 3.6/6 (7.2) kV up to 20.8/36 (42) kV used in power distribution systems with a voltage not exceeding the maximum RMS value of the system voltage Um.

Committee
CT 20
DocumentType
Standard
Pages
120
PublisherName
Comitato Elettrotecnico Italiano
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
HD 620 : 2010 Identical
HD 620 S2:2010 Identical

CEI 20-62/2 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
CEI 20-62/1 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
CEI 20-89 : 2009 SELECTION AND ERECTION OF MEDIUM VOLTAGE ELECTRIC CABLES AND ACCESSORIES - APPLICATION CRITERIA

HD 632 S1:1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
IEC 60228:2004 Conductors of insulated cables
CEI 20-66 : 2010 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
HD 405.1 : S1 AMD 1 TESTS ON ELECTRIC CABLES UNDER FIRE CONDITIONS - TEST ON A SINGLE VERTICAL INSULATED WIRE OR CABLE
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
CEI 20-50 : 2010 ELECTRICAL CABLES ADDITIONAL TEST METHODS
CEI EN 60229 : 2010 ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
HD 48 : 200S1 IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
CEI EN 60228 : 2005 CONDUCTORS OF INSULATED CABLES
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
EN 60885-3:2015 Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
HD 186 : S2 AMD 1 MARKING BY INSCRIPTION FOR THE IDENTIFICATION OF CORES OF ELECTRIC CABLES HAVING MORE THAN 5 CORES
EN 60230:2002 Impulse tests on cables and their accessories
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
CEI 20-29 : 2ED 1997 Insulated cable conductors
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame