CEI EN 50463-2 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING
Hardcopy , PDF
13-02-2019
English
01-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, abbreviations and symbols
4 Requirements
5 Conformity assessment
Annex A (normative) - Test with magnetic induction of
external origin
Annex B (normative) - EMF Configurations
Annex C (informative) - Expressing EMF accuracy
Annex D (informative) - Re-verification and defining of its
regime recommendations
Annex E (informative) - Durability test
Annex ZZ (informative) - Coverage of Essential Requirements
of EU Directives
Bibliography
Contains the requirements applicable to the Energy Measurement Function (EMF) of an Energy Measurement System (EMS) for use on board traction units for measurement of energy supplied directly from/to the Contact Line system.
Committee |
CT 9
|
DevelopmentNote |
Classificazione CEI 9-154. Supersedes CEI EN 50463 which remains current and will be withdrawn on 15/10/2015. (07/2013)
|
DocumentType |
Standard
|
Pages |
96
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 50463-2:2017 | Identical |
EN 62059-32-1:2012 | Electricity metering equipment - Dependability - Part 32-1: Durability - Testing of the stability of metrological characteristics by applying elevated temperature |
IEC 60028:1925 | International standard of resistance for copper |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
EN 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
EN 50463-3:2017 | Railway applications - Energy measurement on board trains - Part 3: Data handling |
EN 60359:2002 | Electrical and electronic measurement equipment - Expression of performance |
EN 50463-4:2017 | Railway applications - Energy measurement on board trains - Part 4: Communication |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 50121-1:2017 | Railway applications - Electromagnetic compatibility - Part 1: General |
CLC/TS 45545-5:2009 | Railway applications - Fire protection on railway vehicles - Part 5: Fire safety requirements for electrical equipment including that of trolley buses, track guided buses and magnetic levitation vehicles |
CEN/TS 45545-2:2009 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
CLC/TS 45545-5:2009 | Railway applications - Fire protection on railway vehicles - Part 5: Fire safety requirements for electrical equipment including that of trolley buses, track guided buses and magnetic levitation vehicles |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 50463-5:2017 | Railway applications - Energy measurement on board trains - Part 5: Conformity assessment |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50125-1:2014 | Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment |
EN 50155:2017 | Railway applications - Rolling stock - Electronic equipment |
IEC 60121:1960 | Recommendation for commercial annealed aluminium electrical conductor wire |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 50388 : 2012 COR 2013 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 62059-32-1:2011 | Electricity metering equipment - Dependability - Part 32-1: Durability - Testing of the stability of metrological characteristics by applying elevated temperature |
EN 50463-1:2017 | Railway applications - Energy measurement on board trains - Part 1: General |
IEC 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.