CEI EN 62040-3 : 2015
Current
The latest, up-to-date edition.
UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
Hardcopy , PDF
English - Italian
01-01-2015
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
5 Electrical conditions, performance and
declared values
6 UPS tests
Annex A (informative) - Uninterruptible power
system (UPS) configurations
Annex B (informative) - Topologies - Uninterruptible
power system (UPS)
Annex C (informative) - UPS switch applications
Annex D (informative) - Purchaser specification
guidelines
Annex E (normative) - Reference non-linear load
Annex F (informative) - Information on backfeed
protection
Annex G (normative) - Input mains failure
Test method
Annex H (informative) - Dynamic output performance
Measurement techniques
Annex I (informative) - UPS Efficiency values
Annex J (normative) - UPS efficiency - Methods
of measurement
Annex K (informative) - UPS functional availability
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Specifies the movable, stationary and fixed electronic uninterruptible power systems (UPS) that deliver single or three-phase fixed frequency a.c. output voltage not exceeding 1000 V a.c. and that incorporate an energy storage system, generally connected through a d.c. link.
Committee |
CT 22
|
DevelopmentNote |
Classificazione CEI 22-24. (09/2002) Supersedes CEI ENV 50091-3 (01/2003)
|
DocumentType |
Standard
|
Pages |
204
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 62040-3:2011 | Identical |
EN 62040-3:2011 | Identical |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60034-22:2009 | Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets |
PREN 60038 : DRAFT 2011 | CENELEC STANDARD VOLTAGES |
EN 60196:2009 | IEC standard frequencies |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
IEEE C57.96-2013 | IEEE Guide for Loading Dry-Type Distribution and Power Transformers |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
CEI 17-11 : 2ED 1987 | INTERRUTTORI DI MANOVRA, SEZIONATORI, INTERRUTTORI - SEZIONATORI IN ARIA E UNITA COMBINATE CON FUSIBILI PER CORRENTE ALTERNATA E TENSIONE NOMINALE NON SUPERIORE A 1.000 V E PER CORRENTE CONTINUA E TENSIONE NOMINALE NON SUPERIORE A 1.200 V |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN ISO 7779:2010 | Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment (ISO 7779:2010) |
EN 60146-2:2000 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
EN 62040-2:2006/corrigendum:2006 | |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
IEC 60050-111:1996 | International Electrotechnical Vocabulary (IEV) - Part 111: Physics and chemistry |
IEC TR 61000-2-8:2002 | Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.