• DD CLC/TS 50544:2010

    Current The latest, up-to-date edition.

    Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-04-2010

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Systems and equipment to be protected
    5 Supply voltages
    6 Overvoltages
    7 Function and characteristics of MO surge arresters
    8 Insulation co-ordination and application of MO surge
      arresters
    9 Selection of MO surge arresters
    Annex A (informative) - Supply voltages
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to non linear metal-oxide resistor type surge arresters (MO surge arresters) without spark gaps designed to limit voltage surges on d.c. traction systems with nominal voltage up to 1500 V.

    Scope - (Show below) - (Hide below)

    This Technical Specification applies to non linear metal-oxide resistor type surge arresters (MO surge arresters) without spark gaps designed to limit voltage surges on d.c. traction systems with nominal voltage up to 1 500 V.

    This Technical Specification applies to protection of equipment.

    Same principles for selection and application apply for MO surge arresters on d.c. traction systems with nominal voltage 3 000 V.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/37/1
    Document Type Standard
    Publisher British Standards Institution
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50526-2:2014 Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices
    IEC 61373:2010 Railway applications - Rolling stock equipment - Shock and vibration tests
    EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
    IEC 61643-12:2008 Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
    EN 61373:2010/AC:2017-09 RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010)
    EN 50122-2:2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 2: PROVISIONS AGAINST THE EFFECTS OF STRAY CURRENTS CAUSED BY D.C. TRACTION SYSTEMS
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
    EN 62305-3:2011 Protection against lightning - Part 3: Physical damage to structures and life hazard
    EN 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
    IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
    EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    IEC 60099-5:2013 Surge arresters - Part 5: Selection and application recommendations
    EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
    CLC/TS 61643-12 : 2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
    PREN 50526-1 : DRAFT 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SURGE ARRESTERS AND VOLTAGE LIMITING DEVICES - PART 1: SURGE ARRESTERS
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC 62305-3:2010 Protection against lightning - Part 3: Physical damage to structures and life hazard
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective