EEMUA 159 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ABOVE GROUND FLAT BOTTOMED STORAGE TANKS - A GUIDE TO INSPECTION, MAINTENANCE AND REPAIR
Hardcopy , PDF
14-10-2023
English
01-01-2014
1 Introduction and scope
2 Tanks and their components - Terminology
and materials of construction
3 Degradation mechanisms and failure modes
4 Corrosion of tanks
5 General inspection techniques and interpretation
of inspection data
6 Tank foundations
7 Tank bottoms (with or without annular plates)
8 Tank shells
9 Tank roofs - general
10 Fixed roofs (cone roofs and dome roofs)
11 Floating roofs
12 Tank appendages
13 Tank coatings
14 Tank insulation
15 Hydrotesting
16 Re-siting of vertical tanks
17 Probabilistic Preventive Maintenance (PPM) for tanks
18 Mothballing
Appendix A - Tank assessment, records and reports
Appendix B - Inspection checklists and frequencies
Appendix C - Typical repair solutions
Appendix D - Sample calculations
Appendix E - Probabilistic Preventive Maintenance (PPM)
Appendix F - Reduction in Young's Modulus and Applicable
Allowable Stresses in Steel components at elevated
temperatures
Appendix G - Self-supporting aluminium roofs
Appendix H (informative) - FEA Requirements regarding
Fit-for-Service assessments
Appendix I (informative) - Supplementary method for
assessing floating roofs And fixed roofs
Appendix J (informative) - Tank turnaround procedure
19 References
20 Bibliography
21 EEMUA Publication - Feedback form
22 EEMUA Publication Catalogue
Describes the key features required for planning and executing inspection, maintenance and repair works on aboveground fully supported vertical steel storage tanks.
DocumentType |
Standard
|
Pages |
424
|
PublisherName |
Engineering Equipment Material Users Association
|
Status |
Superseded
|
SupersededBy |
S.R. CEN TR 15367-2:2007 | PETROLEUM PRODUCTS - GUIDE FOR GOOD HOUSEKEEPING - PART 2: AUTOMOTIVE PETROL FUELS |
API 575 : 2014 | INSPECTION PRACTICES FOR ATMOSPHERIC AND LOW-PRESSURE STORAGE TANKS |
EEMUA 232 : 2016 | SPECIFYING, PROCURING AND MANAGING THIRD PARTY INSPECTION SERVICES |
EEMUA 207 : 2009 | DOUBLE CONCRETE TANKS FOR LIQUEFIED GAS - GUIDE TO DESIGN, CONSTRUCTION AND OPERATION |
EEMUA 168 : 2010 | GUIDE TO THE PRESSURE TESTING OF IN-SERVICE PRESSURISED EQUIPMENT |
EEMUA 190 : 2000 | GUIDE FOR THE DESIGN, CONSTRUCTION AND USE OF MOUNDED HORIZONTAL CYLINDRICAL VESSELS FOR PRESSURISED STORAGE OF LPG AT AMBIENT TEMPERATURE |
EEMUA 193 : 2013 | MANAGING COMPETENCE ASSURANCE FOR PERSONNEL UNDERTAKING IN-SERVICE INSPECTION OF PRESSURE EQUIPMENT |
EEMUA 213 : 2012 | EMISSION REDUCTION FROM OIL STORAGE TANKS AND LOADING OPERATIONS |
EEMUA 180 : 2007 | FRANGIBLE ROOF JOINTS FOR FIXED ROOF STORAGE TANKS - GUIDE FOR DESIGNERS AND USERS |
EEMUA 183 : 2011 | PREVENTION OF TANK BOTTOM LEAKAGE - A GUIDE FOR THE DESIGN AND REPAIR OF FOUNDATIONS AND BOTTOMS OF VERTICAL, CYLINDRICAL, STEEL STORAGE TANKS |
PD CEN/TR 15367-2:2007 | Petroleum products. Guide for good housekeeping Automotive petrol fuels |
EEMUA 217 : 2011 | SAFE AND EFFECTIVE OPERATION OF STORAGE TANKS FOR OIL MOVEMENTS |
S.R. CWA 15740:2008 | RISK-BASED INSPECTION AND MAINTENANCE PROCEDURES FOR EUROPEAN INDUSTRY (RIMAP) |
CEN/TR 15367-2:2007 | Petroleum products - Guide for good housekeeping - Part 2: Automotive petrol fuels |
EI 1540 : 2014 | DESIGN, CONSTRUCTION, COMMISSIONING, MAINTENANCE AND TESTING OF AVIATION FUELLING FACILITIES |
EI Model Code of Safe Practice Part 16:2017 | MODEL CODE OF SAFE PRACTICE - PART 16: GUIDANCE ON TANK CLEANING |
API 545 : 2009 | RECOMMENDED PRACTICE FOR LIGHTNING PROTECTION OF ABOVEGROUND STORAGE TANKS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS |
API 575 CHINESE : 2014 | INSPECTION PRACTICES FOR ATMOSPHERIC AND LOW-PRESSURE STORAGE TANKS |
NACE RP 03 88 : 1995 | IMPRESSED CURRENT CATHODIC PROTECTION OF INTERNAL SUBMERGED SURFACES OF CARBON STEEL WATER STORAGE TANKS |
EEMUA 213 : 2012 | EMISSION REDUCTION FROM OIL STORAGE TANKS AND LOADING OPERATIONS |
EEMUA 180 : 2007 | FRANGIBLE ROOF JOINTS FOR FIXED ROOF STORAGE TANKS - GUIDE FOR DESIGNERS AND USERS |
API 575 : 2014 | INSPECTION PRACTICES FOR ATMOSPHERIC AND LOW-PRESSURE STORAGE TANKS |
EN 10028-3:2017 | Flat products made of steels for pressure purposes - Part 3: Weldable fine grain steels, normalized |
EN 10137-1 : 1995 | PLATES AND WIDE FLATS MADE OF HIGH YIELD STRENGTH STRUCTURAL STEELS IN THE QUENCHED AND TEMPERED OR PRECIPITATION HARDENED CONDITIONS - GENERAL DELIVERY CONDITIONS |
EN 10029:2010 | Hot-rolled steel plates 3 mm thick or above - Tolerances on dimensions and shape |
BS 7613:1994 | Specification for hot rolled quenched and tempered weldable structural steel plates |
EN 10137-3 : 1995 | PLATES AND WIDE FLATS MADE OF HIGH YIELD STRENGTH STRUCTURAL STEELS IN THE QUENCHED AND TEMPERED OR PRECIPITATION HARDENED CONDITIONS - DELIVERY CONDITIONS FOR PRECIPITATION HARDENED STEELS |
EN ISO 13588:2012 | Non-destructive testing of welds - Ultrasonic testing - Use of automated phased array technology (ISO 13588:2012) |
EN 1759-1:2004 | Flanges and their joint - Circular flanges for pipes, valves, fittings and accessories, Class designated - Part 1: Steel flanges, NPS 1/2 to 24 |
API 2000 : 2014 | VENTING ATMOSPHERIC AND LOW-PRESSURE STORAGE TANKS |
API 653 : 2014 | TANK INSPECTION, REPAIR, ALTERATION, AND RECONSTRUCTION |
API 620 : 2013 | DESIGN AND CONSTRUCTION OF LARGE, WELDED, LOW-PRESSURE STORAGE TANKS |
EN 14015:2004 | Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above |
API 12C : 1958 | AII-WELDED OIL STORAGE TANKS |
EN 10210-1:2006 | Hot finished structural hollow sections of non-alloy and fine grain steels - Part 1: Technical delivery conditions |
API 651 : 2014 | CATHODIC PROTECTION OF ABOVEGROUND PETROLEUM STORAGE TANKS |
EEMUA 217 : 2011 | SAFE AND EFFECTIVE OPERATION OF STORAGE TANKS FOR OIL MOVEMENTS |
EN 10028-2:2017 | Flat products made of steels for pressure purposes - Part 2: Non-alloy and alloy steels with specified elevated temperature properties |
EN 10137-2 : 1995 | PLATES AND WIDE FLATS MADE OF HIGH YIELD STRENGTH STRUCTURAL STEELS IN THE QUENCHED AND TEMPERED OR PRECIPITATION HARDENED CONDITIONS - DELIVERY CONDITIONS FOR QUENCHED AND TEMPERED STEELS |
ISO 4628-3:2016 | Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 3: Assessment of degree of rusting |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
EN 10113-1 : 1993 | HOT ROLLED PRODUCTS IN WELDABLE FINE GRAIN STRUCTURAL STEELS - GENERAL DELIVERY CONDITIONS |
ISO 4628-1:2016 | Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 1: General introduction and designation system |
EEMUA 147 : 2016 | RECOMMENDATIONS FOR REFRIGERATED LIQUEFIED GAS STORAGE TANKS |
EN 10155 : 1993 | STRUCTURAL STEELS WITH IMPROVED ATMOSPHERIC CORROSION RESISTANCE - TECHNICAL DELIVERY CONDITIONS |
ASME PV CODE 5 : 2017 | BOILER AND PRESSURE VESSEL CODE - NONDESTRUCTIVE EXAMINATION |
EN 13018:2016 | Non-destructive testing - Visual testing - General principles |
API 650 : 2013 | WELDED TANKS FOR OIL STORAGE |
EI MODEL CODE SAFE PRACTICE PT19 : 2012 | FIRE PRECAUTIONS AT PETROLEUM REFINERIES AND BULK STORAGE INSTALLATIONS |
BS 5422:2009 | Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
BS 7361-1:1991 | Cathodic protection Code of practice for land and marine applications |
EN ISO 16852:2016 | Flame arresters - Performance requirements, test methods and limits for use (ISO 16852:2016) |
ISO 4628-2:2016 | Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 2: Assessment of degree of blistering |
EEMUA 183 : 2011 | PREVENTION OF TANK BOTTOM LEAKAGE - A GUIDE FOR THE DESIGN AND REPAIR OF FOUNDATIONS AND BOTTOMS OF VERTICAL, CYLINDRICAL, STEEL STORAGE TANKS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.