EN 12355:2003+A1:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Food processing machinery - Derinding-, skinning- and membrane removal machines - Safety and hygiene requirements
02-06-2010
31-12-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 List of hazards
5 Safety requirements and/or measures
6 Verification of safety and hygiene requirements and/or measures
7 Information for the user
8 Marking
Annex A (normative) Noise test code for derinding-, skinning-
and membrane removal machines (grade 2)
Annex B (normative) Design principles to ensure the cleanability
of derinding-, skinning- and membrane removal machines
Annex C (normative) Common hazards for food processing machines
and reduction requirements applicable to derinding-,
skinning- and membrane removal machines
Annex ZA (informative) Relationship between this European Standard
and the Essential Requirements of EU Directive 2006/42/EC
Bibliography
1.1This European Standard applies to design, manufacturing, installation, transportation, electrical equipment and cleaning of derinding-, skinning-, and membrane removal machines (see Figures 1 to 5).
The machines described in this standard are used for derinding-, skinning- and membrane removal of meat and fish by cutting at a blade device.
Derinding-, skinning-, and membrane removal machines for domestic purposes and table-top machines are not covered by this standard.
This European Standard relates to:
-derinding machines with tooth roll, hold down roller and blade device;
-skinning- and membrane removal machines with transport- and stripper roll as well as a blade device.
This standard only applies to machines which are manufactured after the date of issue of this standard.
1.2This standard covers the following types of machines:
-Open derinding machines with infeed table and a distance between the floor and the surface of the infeed table from 800 mm to 1 050 mm.
Tooth form of the tooth roll:
Depth <5,0 mm
Pitch<6,5 mm
(see Figures 1 and 2)
Key
1
2
3
4
5
Tooth roll/
Transport roll
Blade
Discharge table
Blade holder
Infeed table
6
7
8
9
10
ON/OFF Switch, cover
Foot switch
Drive
Locking device
Table heightKey
1
2
3
Round product
Cutting thickness < 5 mm
Infeed table
4
5
6
7
8
Tooth roll
Blade holder
Blade
Rind
Stripper comb
Figure 1 - Derinding-, skinning- and membrane Figure 2 - System of an open derinding machine
removal machine
-Automatic derinding machine with infeed, hold down, and outfeed device and a distance between the floor and the surface of the infeed device, e.g. conveyor belt between 800 mm and 1 050 mm.
Tooth form of the tooth roll:
Depth < 5,0 mm
Pitch < 12,0 mm
Hold down roller diameter 175 mm to 240 mm.
(see Figures 3 and 4)
| Committee |
CEN/TC 153
|
| DevelopmentNote |
2003 Edition Re-issued in June 2010 & incorporates AMD 1 2010. (06/2010)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Withdrawn
|
| Standards | Relationship |
| PN EN 12355 : 2005 + A1 2011 | Identical |
| NF EN 12355 : 2003 + A1 2010 | Identical |
| DIN EN 12355:2011-02 | Identical |
| NBN EN 12355 : 2003 + A1 2010 | Identical |
| BS EN 12355 : 2003 | Identical |
| NEN EN 12355 : 2003 + A1 2010 | Identical |
| NS EN 12355 : 2003 + A1 2010 | Identical |
| I.S. EN 12355:2003 | Identical |
| DS EN 12355 : 2003 + A1 2010 | Identical |
| I.S. EN 12355:2003+A1:2010 | Equivalent |
| BS EN 12355:2003+A1:2010 | Equivalent |
| UNE-EN 12355:2003 | Identical |
| BS EN 12355:2003+A1:2010 | Identical |
| UNE-EN 12355:2003+A1:2010 | Identical |